Validation of oxygen consumption measurements during artificial ventilation.

J F Nunn1, K Makita, B Royston.   

Abstract

We describe a system for the absolute calibration of indirect calorimeters, under the conditions of artificial ventilation and increased inspired O2 concentration, in which butane, at a measured flow rate, is burned downstream of an artificial lung. One milliliter of butane requires 6.4 ml O2 for its combustion, and the respiratory quotient is 0.615. With the closed-circuit O2-replenishment method there was no significant systematic error in the measurement of either O2 consumption or CO2 output and a random error with a SD of 8.3 ml/min for O2 consumption and 6.3 ml/min for CO2 output. There were no significant differences in the errors with inspired O2 concentrations between 23.8 and 59.5% and O2 consumptions between 89 and 366 ml/min.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2600040     DOI: 10.1152/jappl.1989.67.5.2129

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  6 in total

1.  Pulmonary oxygen consumption.

Authors:  J F Nunn
Journal:  Intensive Care Med       Date:  1996-04       Impact factor: 17.440

2.  Abstracts of the British Intensive Care Society, autumn meeting. London, October 21, 1989.

Authors: 
Journal:  Intensive Care Med       Date:  1990       Impact factor: 17.440

3.  New metabolic lung simulator: development, description, and validation.

Authors:  Abraham Rosenbaum; Christopher Kirby; Peter H Breen
Journal:  J Clin Monit Comput       Date:  2007-03-01       Impact factor: 2.502

4.  Evaluation of oxygen uptake and delivery in critically ill patients: a statistical reappraisal.

Authors:  G Hanique; T Dugernier; P F Laterre; J Roeseler; A Dougnac; M S Reynaert
Journal:  Intensive Care Med       Date:  1994       Impact factor: 17.440

5.  Oxygen consumption after cardiac surgery--a comparison between calculation by Fick's principle and measurement by indirect calorimetry.

Authors:  P Bizouarn; D Soulard; Y Blanloeil; A Guillet; Y Goarin
Journal:  Intensive Care Med       Date:  1992       Impact factor: 17.440

6.  Multiple propane gas burn rates procedure to determine accuracy and linearity of indirect calorimetry systems: an experimental assessment of a method.

Authors:  Mohammad Ismail; Fabien Basset; Sanaa A Alsubheen; Angela Loucks-Atkinson; Matthew Atkinson; Thamir Alkanani; Liam P Kelly
Journal:  PeerJ       Date:  2022-08-29       Impact factor: 3.061