Literature DB >> 25998460

Dual gold nanoparticle lateflow immunoassay for sensitive detection of Escherichia coli O157:H7.

Minghui Chen1, Zhibiao Yu2, Daofeng Liu1, Tao Peng1, Kun Liu1, Shuying Wang1, Yonghua Xiong3, Hua Wei3, Hengyi Xu3, Weihua Lai4.   

Abstract

Two patterns of signal amplification lateral flow immunoassay (LFIA), which used anti-mouse secondary antibody-linked gold nanoparticle (AuNP) for dual AuNP-LFIA were developed. Escherichia coli O157:H7 was selected as the model analyte. In the signal amplification direct LFIA method, anti-mouse secondary antibody-linked AuNP (anti-mouse-Ab-AuNP) was mixed with sample solution in an ELISA well, after which it was added to LFIA, which already contained anti-E. coli O157:H7 monoclonal antibody-AuNP (anti-E. coli O157:H7-mAb-AuNP) dispersed in the conjugate pad. Polyclonal antibody was the test line, and anti-mouse secondary antibody was the control line in nitrocellulose (NC) membrane. In the signal amplification indirect LFIA method, anti-mouse-Ab-AuNP was mixed with sample solution and anti-E. coli O157:H7-mAb-AuNP complex in ELISA well, creating a dual AuNP complex. This complex was added to LFIA, which had a polyclonal antibody as the test line and secondary antibody as the control line in NC membrane. The detection sensitivity of both LFIAs improved 100-fold and reached 1.14×10(3) CFU mL(-1). The 28 nm and 45 nm AuNPs were demonstrated to be the optimal dual AuNP pairs. Signal amplification LFIA was perfectly applied to the detection of milk samples with E. coli O157:H7 via naked eye observation.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Dual lateral flow immunoassay; E. coli O157:H7; Signal amplification

Mesh:

Substances:

Year:  2015        PMID: 25998460     DOI: 10.1016/j.aca.2015.03.023

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  9 in total

1.  Enhancement of lateral flow immunoassay by alkaline phosphatase: a simple and highly sensitive test for potato virus X.

Authors:  Vasily G Panferov; Irina V Safenkova; Yury A Varitsev; Anatoly V Zherdev; Boris B Dzantiev
Journal:  Mikrochim Acta       Date:  2017-12-06       Impact factor: 5.833

2.  Strategy for Accurate Detection of Escherichia Coli O157:H7 in Ground Pork Using a Lateral Flow Immunoassay.

Authors:  Song Cheng; Ming-Hui Chen; Gang-Gang Zhang; Zhi-Biao Yu; Dao-Feng Liu; Yong-Hua Xiong; Hua Wei; Wei-Hua Lai
Journal:  Sensors (Basel)       Date:  2017-04-02       Impact factor: 3.576

3.  How to Improve Sensitivity of Sandwich Lateral Flow Immunoassay for Corpuscular Antigens on the Example of Potato Virus Y?

Authors:  Shyatesa C Razo; Vasily G Panferov; Irina V Safenkova; Yuri A Varitsev; Anatoly V Zherdev; Elena N Pakina; Boris B Dzantiev
Journal:  Sensors (Basel)       Date:  2018-11-15       Impact factor: 3.576

Review 4.  Nanomaterial application in bio/sensors for the detection of infectious diseases.

Authors:  Elham Sheikhzadeh; Valerio Beni; Mohammed Zourob
Journal:  Talanta       Date:  2020-12-17       Impact factor: 6.057

5.  Ultrasensitive nano-gold labelled, duplex lateral flow immunochromatographic assay for early detection of sugarcane mosaic viruses.

Authors:  Raja Muthuramalingam Thangavelu; Nithya Kadirvel; Parameswari Balasubramaniam; Rasappa Viswanathan
Journal:  Sci Rep       Date:  2022-03-09       Impact factor: 4.379

6.  Immunomagnetic separation and size-based detection of Escherichia coli O157 at the meniscus of a membrane strip.

Authors:  Hyeonjeong Lee; Jeongin Hwang; Yunsung Park; Donghoon Kwon; Sanghee Lee; Inseok Kang; Sangmin Jeon
Journal:  RSC Adv       Date:  2018-07-23       Impact factor: 3.361

7.  Nanozyme-Mediated Dual Immunoassay Integrated with Smartphone for Use in Simultaneous Detection of Pathogens.

Authors:  Nan Cheng; Yang Song; Mohamed M A Zeinhom; Yu-Chung Chang; Lina Sheng; Haolin Li; Dan Du; Lei Li; Mei-Jun Zhu; Yunbo Luo; Wentao Xu; Yuehe Lin
Journal:  ACS Appl Mater Interfaces       Date:  2017-11-07       Impact factor: 9.229

8.  Rapid Detection of Escherichia coli O157 and Shiga Toxins by Lateral Flow Immunoassays.

Authors:  Jinliang Wang; Robab Katani; Lingling Li; Narasimha Hegde; Elisabeth L Roberts; Vivek Kapur; Chitrita DebRoy
Journal:  Toxins (Basel)       Date:  2016-03-25       Impact factor: 4.546

9.  Comparison of Single- and Mixed-Sized Gold Nanoparticles on Lateral Flow Assay for Albumin Detection.

Authors:  Sasima Chotithammakul; Michael B Cortie; Dakrong Pissuwan
Journal:  Biosensors (Basel)       Date:  2021-06-26
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.