Transcutaneous carbon dioxide monitoring to avoid hypercapnia during complex catheter ablations: a feasibility study.

Daniel J Cantillon1, Lisa M Keene, Ali Hakim, Stephanie Spencer, Jennifer Petro, Mary Ludvik, Dawn Schell.   

Abstract

PURPOSE: The aim of this study was to determine if transcutaneous CO(2) monitoring (TCO(2)) is feasible to avoid hypercapnia during complex catheter ablation. Cumulative analgesic and anxiolytic effects during complex catheter ablation can rarely provoke hypoventilation and respiratory complications. End tidal CO(2) monitors have limitations in non-ventilated patients, and frequent arterial blood gas sampling is impractical.
METHODS: Consecutive patients undergoing catheter ablation for atrial fibrillation (AF) or ventricular tachycardia (VT) received continuous TCO(2) monitoring. Procedural evaluation of TCO(2) was performed concomitantly with point-of-care arterial blood gas testing. Endpoints included PCO(2) protocol feasibility, TCO(2)/PCO(2) agreement, and avoidance of hypercapnia-related procedural complications.
RESULTS: Fifty patients [AF n = 36 (72 %), VT n = 14 (28 %)] underwent catheter ablation (mean 221.7 ± 57.0 min duration, median 41.4 ± 21.1 min fluoroscopy) in which 6.0 ± 2.6 mg midazolam and 449 ± 225.5 mcg of fentanyl were administered. Monitoring protocol implementation was feasible in 50/50 (100 %) cases. Protocol-driven anesthesia consultation avoided an unplanned intubation in 1 case (2 %) and there was only 1 unplanned intubation (2 %) for oxygen desaturation due to heart failure without hypercapnia during a VT ablation (TCO(2)/PCO(2) agreement <5 mmHg). There were no respiratory or pulseless electrical arrests (0 %) in the study. TCO(2) and PCO(2) correlated well (baseline: r = 0.75, p < 0.001; 1 h:r= 0.72, p < 0.001; 2 h: r = 0.55, p = 0.003; 3 h: r = 0.79, p = 0.02). However, desired agreement was lower than expected [baseline: 33/50 (66 %) < 5 mmHg, 48/50 (96 %) <10 mmHg; 1 h: 29/45 (64 %) < 5 mmHg, 39/45 (87 %) < 10 mmHg; 2 h: 14/26 (54 %) < 5 mmHg, 22/26 (85 %) < 10 mmHg; 3 h: 7/11 (64 %) < 5 mmHg, 10/11 (91 %) < 10 mmHg; >3 h: 1/3 (33 %) < 5 mmHg, 2/3 (66 %) < 10 mmHg].
CONCLUSION: Transcutaneous CO2 monitoring is feasible during complex catheter ablation and correlates with invasively obtained data. However, further development is needed to achieve the desired level of agreement.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25997689     DOI: 10.1007/s10840-015-0013-5

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  10 in total

Review 1.  Guidelines for Clinical Intracardiac Electrophysiologic Studies. A report of the American College of Cardiology/American Heart Association Task Force on Assessment of Diagnostic and Therapeutic Cardiovascular Procedures.

Authors: 
Journal:  Circulation       Date:  1989-12       Impact factor: 29.690

2.  Noninvasive intraoperative monitoring of carbon dioxide in children: endtidal versus transcutaneous techniques.

Authors:  Mace A Nosovitch; Joel O Johnson; Joseph D Tobias
Journal:  Paediatr Anaesth       Date:  2002-01       Impact factor: 2.556

3.  Delayed respiratory depression with fentanyl.

Authors:  J Smydo
Journal:  Anesth Prog       Date:  1979 Mar-Apr

4.  Consensus statement of the Conference on the State of the Art of Electrophysiologic Testing in the Diagnosis and Treatment of Patients with Cardiac Arrhythmias.

Authors:  S H Rahimtoola; D P Zipes; M Akhtar; H Burchell; J Mason; R Myerburg; R O'Rourke; J Ruskin; R Schlant; B Surawicz
Journal:  Circulation       Date:  1987-04       Impact factor: 29.690

5.  Noninvasive monitoring of carbon dioxide in infants and children with congenital heart disease: end-tidal versus transcutaneous techniques.

Authors:  John Wilson; Pierantonio Russo; JoAnne Russo; Joseph D Tobias
Journal:  J Intensive Care Med       Date:  2005 Sep-Oct       Impact factor: 3.510

6.  Bubble and ventilator-derived nasal continuous positive airway pressure in premature infants: work of breathing and gas exchange.

Authors:  S E Courtney; D J Kahn; R Singh; R H Habib
Journal:  J Perinatol       Date:  2010-04-15       Impact factor: 2.521

7.  The revised digital transcutaneous PCO2/SpO2 ear sensor is a reliable noninvasive monitoring tool in patients after cardiac surgery.

Authors:  Regine Roediger; Beatrice Beck-Schimmer; Oliver M Theusinger; Denise Rusch; Burkhardt Seifert; Donat R Spahn; Edith R Schmid; Werner Baulig
Journal:  J Cardiothorac Vasc Anesth       Date:  2010-09-20       Impact factor: 2.628

8.  Detection of hypoventilation during deep sedation in patients undergoing ambulatory gynaecological hysteroscopy: a comparison between transcutaneous and nasal end-tidal carbon dioxide measurements.

Authors:  G S De Oliveira; S Ahmad; P C Fitzgerald; R J McCarthy
Journal:  Br J Anaesth       Date:  2010-04-23       Impact factor: 9.166

Review 9.  Midazolam and other benzodiazepines.

Authors:  K T Olkkola; J Ahonen
Journal:  Handb Exp Pharmacol       Date:  2008

10.  Noninvasive monitoring of PaCO(2) during one-lung ventilation and minimal access surgery in adults: End-tidal versus transcutaneous techniques.

Authors:  Paul Cox; Joseph D Tobias
Journal:  J Minim Access Surg       Date:  2007-01       Impact factor: 1.407

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.