Literature DB >> 25997093

[The Effect of Non-Depolarising Muscle Relaxants on Ocular Pulse Amplitude and Intraocular Pressure].

H Zuche1, E Morinello2, Anja Viestenz1, M F Fiorentzis1, T Volk2, B Seitz1, Arne Viestenz1.   

Abstract

AIM: In general anaesthesia (GA) for ocular surgery the chosen non-depolarising muscle relaxant has a high influence on the fluctuations of intraocular pressure (IOP) and ocular pulse amplitude (OPA). PATIENTS AND METHODS: In 229 patients, who needed GA for their ophthalmic surgery, OPA and IOP were measured with the dynamic contour tonometer (DCT) before and 5 minutes after intubation. For GA, three groups of non-depolarising muscle relaxants, namely, mivacurium (n = 71), atracurium (n = 91) and rocuronium (n = 67) were used.
RESULTS: The IOP decreased by about 4.0 ± 2.3 mmHg using mivacurium in GA, by about 6.1 ± 2.2 mmHg using atracurium and by about 7.4 ± 1.7 mmHg using rocuronium (p < 0.001). The relative decrease of the IOP was 20% for mivacurium, 31% for atracurium and 37% for rocuronium. For mivacurium the OPA decreased from 3.4 ± 1.5 mmHg to 2.2 ± 1.1 mmHg (p < 0.001) in contrast to atracurium (decrease from 3.6 ± 1.5 mmHg to 1.8 ± 0.8 mmHg; p < 0.001) and rocuronium (decrease from 3.1 ± 1.6 mmHg to 1.7 ± 0.9 mmHg; p < 0.001). Mean OPA reduction was lowest with mivacurium (1.3 mmHg) and the highest with atracurium (1.7 mmHg). The mean relative decrease of the OPA was 34% with mivacurium, 46% with atracurium and 43% with rocuronium (p < 0.001). There was no linear correlation between the relative OPA decrease and the relative IOP decrease.
CONCLUSION: Risks for ophthalmic surgery may be minimised by avoiding mivacurium in general anaesthesia. Due to its negative effects on IOP and OPA mivacurium does not seem to be suitable for operations with a large opening in the eye such as penetrating keratoplasty and block excision. Rocuronium can be used because it induces a favourised intraoperative decrease of the IOP. Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25997093     DOI: 10.1055/s-0035-1545974

Source DB:  PubMed          Journal:  Klin Monbl Augenheilkd        ISSN: 0023-2165            Impact factor:   0.700


  2 in total

1.  Penetrating Keratoplasty for Keratoconus - Excimer Versus Femtosecond Laser Trephination.

Authors:  Berthold Seitz; Achim Langenbucher; Tobias Hager; Edgar Janunts; Moatasem El-Husseiny; Nora Szentmáry
Journal:  Open Ophthalmol J       Date:  2017-07-31

2.  Effects of Cisatracurium, Rocuronium, and Mivacurium on Intraocular Pressure During Induction of General Anesthesia in Ophthalmic Surgery.

Authors:  Fang Tan; Wenxian Li; Shuangshuang Li; Xiao Hu
Journal:  Drug Des Devel Ther       Date:  2020-03-24       Impact factor: 4.162

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.