Bo-Ram Choi1, Sun-Young Kang2. 1. Department of Physical Therapy, College of Medical and Life Science, Silla University, Republic of Korea. 2. Department of Physical Therapy, Graduate School, Yonsei University, Republic of Korea.
Abstract
[Purpose] The purpose of this study was to determine the inter- and intra-examiner reliability of measurement methods for femoral anterversion during Craig's test. [Subjects and Methods] The study included 37 healthy participants (20 males and 17 females). Two novice examiners (Department of Physical Therapy students at Silla University) used three different methods to measure the femoral anterversion during Craig's test: a goniometer, a goniometer with a laser beam, and an inclinometer. [Results] The intra-examiner reliability was high for both examiners with all three measurement methods, with scores of 0.82, 0.86, and 0.73 for examiner 1 and 0.74, 0.78, and 0.72 for examiner 2 for the goniometer, goniometer with the laser beam, and inclinometer, respectively. The inter-examiner reliability during Craig's test was below moderate for both the goniometer (0.25) and inclinometer (0.27) and moderate for the goniometer with the laser beam (0.62). [Conclusion] This study found that Craig's test using a goniometer with a laser beam had high intra-examiner reliability and moderate inter-examiner reliability. Clinically, these findings may supplement existing measurement skills and reduce the difficulty of locating the goniometer axis during Craig's test.
[Purpose] The purpose of this study was to determine the inter- and intra-examiner reliability of measurement methods for femoral anterversion during Craig's test. [Subjects and Methods] The study included 37 healthy participants (20 males and 17 females). Two novice examiners (Department of Physical Therapy students at Silla University) used three different methods to measure the femoral anterversion during Craig's test: a goniometer, a goniometer with a laser beam, and an inclinometer. [Results] The intra-examiner reliability was high for both examiners with all three measurement methods, with scores of 0.82, 0.86, and 0.73 for examiner 1 and 0.74, 0.78, and 0.72 for examiner 2 for the goniometer, goniometer with the laser beam, and inclinometer, respectively. The inter-examiner reliability during Craig's test was below moderate for both the goniometer (0.25) and inclinometer (0.27) and moderate for the goniometer with the laser beam (0.62). [Conclusion] This study found that Craig's test using a goniometer with a laser beam had high intra-examiner reliability and moderate inter-examiner reliability. Clinically, these findings may supplement existing measurement skills and reduce the difficulty of locating the goniometer axis during Craig's test.
Entities:
Keywords:
Craig’s test; Goniometer with a laser; Inclinometer
Lower extremity (LE) malalignment influences the load distribution on the joints,
mechanical efficiency of the muscles, and proprioceptive orientation and feedback from the
hip and knee, resulting in altered neuromuscular function and control of the lower
extremities1, 2). Among these LE alignment variables, femoral anteversion has been
identified as a risk factor for hip and knee joint injury3, 4). Increased femoral
anteversion can increase hip adduction and knee abduction because the patella shifts to the
medial side of the femoral condyle groove, thereby increasing the Q-angle and ultimately
resulting in knee valgus deformity5). As
females have a wider pelvis, larger Q-angle, and larger femoral anteversion values than
males, more females experience frontal plane stress while engaging in functional tasks4). Thus, an accurate assessment of femoral
anteversion is important for diagnosing and preventing hip and knee injuries6).Femoral anteversion is the degree of forward projection of the femoral neck from the
frontal plane of the shaft7). Various
methods and equipment have been used to measure femoral anteversion. Radiographic evidence
and complex trigonometric formulae have been employed to determine the femoral anteversion
angle and the femoral neck shaft angle8).
However, the limitations of radiographs do not allow for the axes to be placed
accurately9). Ultrasound (US), which is
both inexpensive and noninvasive, can be used to measure femoral anteversion, but it is not
easy for a novice examiner to find the true axis of the femur10). Computed tomography (CT) is one of the most reliable methods of
measurements for determining the rotational alignment of the lower extremities11). The inter-examiner reliability of femoral
anteversion measurements with CT is higher than with magnetic resonance imaging (MRI), and
there is a significant correlation between the results of CT and the internal rotation of
the hip joint. Although imaging can be useful, a physical examination is needed in daily
clinical practice to determine femoral anteversion. Craig’s test is the most commonly used
physical method for measuring femoral anteversion. Craig’s test results correlate with
commonly used radiographic techniques (r = 0.93)12). Studies have reported that Craig’s test has high
intra-examiner reliability. However, the examiner may find it difficult to locate and
palpate the greater trochanter and the goniometer axis because one hand has to maintain the
internal rotation of the hip while the other hand measures the angle between a virtual
vertical line, which is based on different standards among examiners and the bisection line
of the tibia using the goniometer. Examiners may find it difficult to control the goniometer
axis while maintaining the maximal lateral position of the greater trochanter.Thus, there is a continuing need for a method to measure femoral anteversion that is easy
to use, accurate, and reproducible. The purpose of this study was to examine the inter- and
intra-examiner reliability of a goniometer, an inclinometer, and a goniometer with a laser,
all of which are tools used to measure femoral anteversion in Craig’s test.
SUBJECTS AND METHODS
Thirty-seven healthy volunteers (20 males, age 28.7±1.1 years, height 1.71±0.4 m, and mass
72.8±7.7 kg; 17 females, age 26.3±1.6 years, height 1.64±0.2 m, and mass 67.3±5.9 kg)
participated. The inclusion criteria were no prior medical history of surgery and no acute
LE orthopedic injury or lumbar spine injury for at least the previous 6 months. Before
taking part, the participants provided written informed consent. This study was approved by
the Institutional Review Board at Silla University.We used three methods to measure the femoral anteversion. The first method employed the
traditional Craig’s test. The participants were placed in a prone position, with 90° flexion
of the knee joint. Using one hand, the examiner palpated the greater trochanter until it was
positioned laterally and maximally during passive internal rotation of the hip joint. The
examiner then used a handheld goniometer with his other hand to measure the angle between
the tibial lines, a line bisecting the medial and lateral malleoli, and an imaginary
vertical line extending from the table13, 14).The second method also started with Craig’s test but used an Acumar digital inclinometer
(Lafayette Instrument Co., Lafayette, IN, USA) instead of a handheld goniometer. The
inclinometer was attached along the line between the fibular head and the lateral malleolus.
Calibration was performed with the vertical line extending from the table during each
Craig’s test, and the angle displacement between the vertical line and the end position was
recorded.In the third method, femoral anteversion was measured using a handheld goniometer with a
leveling laser beam (LD-SL01, LAND Group, Zhejiang, PR China). The leveling laser beam,
located on a tripod, was used to project both vertical and horizontal beams. The
intersection point of the vertical and horizontal lines was focused on the center of the
subject’s patella. During Craig’s test, the position of the goniometer axis for the virtual
vertical line was located using the vertical laser beam.Two novice examiners (fourth-year undergraduates in the Department of Physical Therapy)
used the three methods in all the tests. The measurement methods were standardized for both
examiners in a pilot test. The examiners’ results from the first session were compared with
the corresponding results from the second session to calculate the intra-examiner
reliability of each method. To avoid any learning effect, each examiner had a 1-day interval
between the first and second sessions. On the same day, the other examiner evaluated the
same subject in an identical fashion to calculate the inter-examiner reliability. All the
data were recorded by a third examiner to avoid comparison of the data during the three
methods for each of the two examiners. The examiners collected the data during the tests to
ensure that the participants remained as stable as possible for all three methods. To ensure
that the examiners remained blinded to each other’s assessments, the two examiners entered
the examination room independently. Each of the examiners performed three trials (one
session for each trial), and each measurement was taken on the right femur. The order of the
methods was randomized.The data were analyzed using PASW Statistics for Windows (Version 18.0; SPSS Inc., Chicago,
IL, USA). Intraclass correlation coefficients (ICC) (3,1) and 95% confidence intervals (CI)
were used to analyze the intra-examiner and inter-examiner reliability. The ICC reference
values of the present study for the reliability of the measurements were poor (less than
0.25), low (0.26–0.49), moderate (0.50–0.69), high (0.70–0.89), and very high (above
0.90)15).
RESULTS
The reliability of both examiners was high with all the Craig’s test methods. The
goniometer, combined with the laser, showed the highest reliability (ICC 0.68–0.93) among
the methods assessed (Table 1). The reliabilities of both the goniometer and the inclinometer were low.
However, the Craig’s test with the goniometer and laser showed moderate reliability (ICC
0.13–0.83) (Table 2).
Table 1.
ICC3,1 and 95% CI for day-to-day intra-examiner reliability
Session
Examiner 1
Examiner 2
Mean (SD)
ICC (95%CI)
Mean (SD)
ICC (95%CI)
Goniometer
1
10.5 ± 1.4*
0.82 (0.61 to 0.92)
7.9 ± 1.2
0.74 (0.43 to 0.88)
2
10.4 ± 1.2
8.1 ± 1.6
Goniometer with a laser beam
1
10.3 ± 1.0
0.86 (0.68 to 0.93)
10.0 ± 1.2
0.78 (0.51 to 0.9)
2
10.0 ± 1.2
9.7 ± 1.3
Inclinometer
1
9.6 ± 1.3
0.73 (0.39 to 0.88)
8.7 ± 1.9
0.72 (0.37 to 0.87)
2
10.0 ± 0.9
8.3 ± 1.6
*Degree
Table 2.
ICC3,1 and 95% CI for inter-examiner reliability of day 1
ICC (95%CI)
Goniometer
0.25 (−0.68 to 0.67)
Goniometer with a laser beam
0.62 (0.13 to 0.83)
Inclinometer
0.27 (−0.64 to 0.68)
*Degree
DISCUSSION
The aim of this study was to determine the intra- and inter-examiner reliabilities of
femoral anteversion measurements obtained using Craig’s test with a goniometer, an
inclinometer, and a goniometer with a laser beam. The results showed that Craig’s test using
a goniometer with a laser beam had moderate inter-examiner reliability and that the
reliability was higher than that of the other methods.Various techniques have been used to measure femoral anteversion. Ryder’s method8) is similar to Craig’s test in terms of the
goniometer axis. The angle between a line extending from the longitudinal axis of the tibia,
assumed to be vertical, to the dorsal condyle of the femur and a vertical line to the ground
is considered to represent femoral anteversion. The femoral torsion index (FTI) is another
femoral anteversion measure. It is considered easier to find the femoral torsion. Rather
than finding the longitudinal axis of the tibia, the femoral torsion axis is found using a
line connecting the dorsal surfaces of the medial and lateral condyle of the femur. Although
the FTI is more reliable than Ryder’s method16), we focused on the reliability of the vertical line extending to
the ground. Although both Ryder’s method and the FTI utilize the longitudinal axis of the
femur, the imaginary vertical line could vary with the standing posture and head posture of
the rater. The results of our study showed that Craig’s test using a goniometer with a laser
beam was more reliable than the traditional Craig’s test. The laser provides a reference
axis for the imaginary vertical line.Craig’s test has shown high reliability in measuring femoral anteversion12, 15). Ruwe et al. reported that Craig’s test of the femoral anteversion
angle correlated with intraoperative measures (r = 0.930) and with
radiographic techniques (r = 0.941). However, other studies found that the
results of physical examinations of femoral anteversion were not consistent with those
obtained with imaging techniques10, 16). Souza and Powers17) reported that physical examinations had such a wide
confidence interval that their clinical utility may even be called into question. One
problem when using a goniometer is the position of the axis. Although goniometers are
commonly used to measure the range of motion, it is difficult to simultaneously handle the
instrument and identify reference anatomical points. Additionally, anatomical errors and
undesirable movements may compromise the results18,
19). Another possible reason why
goniometers are less reliable is that the experience and ability of the examiner may, at
least partially, affect the reproducibility of the measurement20). Our results showed that the inclinometer method with
Craig’s test had lower reliability because of the difficulty in locating the attachment
position for the inclinometer. We used a goniometer with a laser beam to increase the
reproducibility in assessing the vertical axis, resulting in better inter-examiner
reliability than the traditional Craig’s test. Using a goniometer with a laser beam, the
novice examiner can measure femoral anteversion with a more accurate reference axis.
However, the examiner cannot ensure the femoral anteversion angle using a goniometer with a
laser beam because physical examination methods do not correlate well with imaging
techniques (CT, MRI, US)10, 16). Clinicians are aware that goniometer measurements are not
interchangeable with true femoral torsion obtained by imaging techniques.Although we controlled the standard measurement axis with the laser beam, we did not
control subject posture during the measurement. Pelvic location was not in the same prone
position on the two measurement days. Because the acetabulum location is changed by the
pelvic tilt position21), the pelvic
location could affect the range of motion in femur rotation. Additionally, no lower
extremity muscle length test was performed; thus, the iliopsoas muscles and rectus femoris
can affect the pelvic and femur locations in a prone position. The future studies should
consider participants’ positions during measurement and examine relationship between muscle
length in lower extremity and femoral anteversion.In this study, we found that Craig’s test using a goniometer with the laser beam method
showed high intra-examiner reliability and moderate inter-examiner reliability. Clinically,
these findings may supplement existing measurement skills and reduce the difficulty in
locating the goniometer axis during Craig’s test.
Authors: Thomas Andreas Kalteis; Martin Handel; Boris Herbst; Joachim Grifka; Tobias Renkawitz Journal: J Arthroplasty Date: 2008-11-01 Impact factor: 4.757