| Literature DB >> 25995547 |
Hyeong-Dong Kim1, Denis Brunt2, Hyun Dong Je3.
Abstract
[Purpose] This study investigated the effects of accuracy constraints (targets) placed on the stepping-limb heel-strike (HS) on the electromyogram (EMG) and ground reaction forces (GRFs) during gait initiation.Entities:
Keywords: Electromyogram; Gait initiation; Ground reaction forces
Year: 2015 PMID: 25995547 PMCID: PMC4433968 DOI: 10.1589/jpts.27.1023
Source DB: PubMed Journal: J Phys Ther Sci ISSN: 0915-5287
Subject characteristics
| Gender | Number | Age (years) | Height (cm) | Weight (kg) |
|---|---|---|---|---|
| Male | 10 | 30.2 (2.78) | 174.8 (5) | 71.2 (3.79) |
| Female | 10 | 28 (2.69) | 164.6 (5.24) | 53.4 (3.09) |
| Total | 20 | 29.2 (2.9) | 169.9 (7.3) | 62.8 (9.72) |
Means (SD) of temporal events (ms)
| Dependent variables | Gait Initiation | Stepping | ||
|---|---|---|---|---|
| no target | target | no target | target | |
| Stepping limb peak Fx# | 340 (49)§ | 423 (42)§Ω | 329 (47)¶ | 368 (73)¶Ω |
| Stepping limb toe-off*+ | 511 (76)§Γ | 613 (81)§Ω | 475 (69)¶Γ | 548 (91)¶Ω |
| Stepping limb heel-strike*+ | 890 (74)§Γ | 1008 (86)§Ω | 968 (71)¶Γ | 1071 (108)¶Ω |
| Stance limb toe-off*+ | 1024 (76)§Γ | 1219 (156)§Ω | 1093 (85)¶Γ | 1257 (153)¶Ω |
Values represent mean ± standard deviation (SD). *Significant main effect of target (p<0.01 or p<0.05). +Significant main effect of initiation condition (p<0.01 or p<0.05). #Significant interaction (p < 0.05). §Ω¶ΓSignificant difference between conditions (p<0.01 or p<0.05).
Means (SE) of EMG dependent variables (ms.v)
| Dependent variables | Gait Initiation | Stepping | ||
|---|---|---|---|---|
| no target | target | no target | target | |
| Stance limb TAEMG1# | 340 (49)†‡ | 423 (42)‡ | 329 (47)†§ | 368 (73)§ |
| Stance limb TAEMG2* | 511 (76)∏ | 613 (81)∏ | 475 (69)¶ | 548 (91)¶ |
| Stepping limb TAEMG1* | 890 (74)∏ | 1008 (86)∏ | 968 (71)¶ | 1071 (108)¶ |
| Stepping limb TAEMG2 | 1024 (76) | 1219 (156) | 1093 (85) | 1257 (153) |
Values represent mean ± standard deviation (SD). TAEMG: tibialis anterior electromyogram. *Significant main effect of target (p<0.01 or p<0.05). #Significant interaction (p<0.05). †‡§∏¶Significant difference between conditions (p<0.01 or p<0.05).
Means (SD) of peak (%BW) and slope (%BW/s) force plate dependent variables
| Dependent variable | Gait Initiation | Stepping | ||
|---|---|---|---|---|
| no target | target | no target | target | |
| Stepping limb peak Fx* | 39.6 (6)∏ | 26 (7.8)∏ | 40.8 (9.6)¶ | 25.7 (7.2)¶ |
| Stepping limb slope Fx* | 125.2 (42)∏ | 62 (22.5)∏ | 120.6 (26.4)¶ | 75.6 (32.3)¶ |
| Stance limb peak Fx# | 81.8 (13)∏§ | 52.6 (12)∏ | 66.3 (15)§¶ | 47.5 (13)¶ |
| Stance limb slope Fx* | 318.2 (63)∏ | 208.2 (53)∏ | 313.1 (87)¶ | 192.5 (54)¶ |
Values represent mean ± standard deviation (SD). Fx: anteroposterior ground reaction force; %BW: percent body weight; %BW/s: percent body weight per second. *Significant main effect of target (p<0.01 or p<0.05). #Significant interaction (p<0.05). ∏¶§Significant difference between conditions (p<0.01 or p<0.05).