| Literature DB >> 25994801 |
Jin Soo Kang1, Min-Ah Park2, Jae-Yup Kim3, Sun Ha Park4, Dong Young Chung1, Seung-Ho Yu1, Jin Kim1, Jongwoo Park3, Jung-Woo Choi1, Kyung Jae Lee1, Juwon Jeong1, Min Jae Ko5, Kwang-Soon Ahn6, Yung-Eun Sung1.
Abstract
Nickel nitride electrodes were prepared by reactive sputtering ofEntities:
Year: 2015 PMID: 25994801 PMCID: PMC5386249 DOI: 10.1038/srep10450
Source DB: PubMed Journal: Sci Rep ISSN: 2045-2322 Impact factor: 4.379
Figure 1(a,b) The XRD spectra of Pt (blue lines), Ni (green lines), and nickel nitride films (red lines) on FTO glasses (black lines), with (b) showing a close-up region within (a).
Figure 2(a,b) TEM images at different magnifications and the (c) SAED pattern of a nickel nitride film. (d,e) SEM image of the (d) Pt and (e) nickel nitride film on the FTO glasses. The insets of (d) and (e) are high-magnification images.
Figure 3(a) XPS spectra of the nickel (black lines) and nickel nitride (red lines) films across a wide scan range for (b) the Ni 2p core level peak, and (c) the N 1s core level peak. (d) The Ni K-edge XANES spectra of nickel and nickel nitride. (e,f) The k3-weighted Fourier transform of the EXAFS spectra at the Ni K-edge for (e) nickel and (f) nickel nitride.
Figure 4Cyclic voltammograms (CVs) of (a) Pt and (b) nickel nitride electrodes for the iodide redox couple. CVs of (c) Pt and (d) nickel nitride electrodes for the polysulfide redox couple.
Figure 5TEM images and elemental EF-TEM maps of the nickel nitride electrodes (a) before and (b,c) after 10 CV cycles in the iodide and polysulfide redox electrolytes.
Figure 6Tafel polarization curves of symmetric dummy cells with Pt (blue lines/squares) or nickel nitride (red lines/circles) electrodes for (a) iodide and (b) polysulfide electrolytes. Impedance spectra of the symmetric dummy cells for (c) iodide and (d) polysulfide electrolytes, with the insets showing the enlarged spectra.
Parameters determined by fitting the impedance spectra of symmetric dummy cells with Pt and nickel nitride electrodes.
| Pt | Iodide | 3.37 | 64.2 |
| Nickel nitride | Iodide | 1719.50 | 73.6 |
| Pt | Polysulfide | 51.80 | 266.8 |
| Nickel nitride | Polysulfide | 2.49 | 3192.0 |
Figure 7(a) Photocurrent density-voltage (J-V) characteristics under illumination (light intensity: 100 mW cm−2, AM 1.5G filter) and (b) IPCE spectra of the DSCs with Pt (blue lines) or nickel nitride (red lines) CEs. (c) Photocurrent density-voltage (J-V) characteristics under illumination (light intensity: 100 mW cm−2, AM 1.5G filter) and (d) IPCE spectra of the QDSCs with each type of CE. The DSCs and QDSCs utilized the iodide and polysulfide redox electrolyte, respectively.
Summary of J-V characteristics for DSCs and QDSCs employing Pt and nickel nitride CEs.
| DSCs with Pt CEs | 0.812(0.812 ± 0.003) | 13.8(13.7 ± 0.4) | 68.0(66.9 ± 1.6) | 7.62(7.41 ± 0.19) |
| DSCs with nickel nitride CEs | 0.738(0.738 ± 0.011) | 12.8(12.5 ± 0.4) | 39.7(38.8 ± 1.1) | 3.75(3.58 ± 0.14) |
| QDSCs with Pt CEs | 0.529(0.507 ± 0.019) | 9.6(8.8 ± 0.8) | 39.4(38.4 ± 0.9) | 2.01(1.75 ± 0.23) |
| QDSCs with nickel nitride CEs | 0.525(0.518 ± 0.006) | 11.8(11.6 ± 0.2) | 45.2(44.7 ± 0.5) | 2.80(2.76 ± 0.04) |
The statistical data (average ± standard deviation) of three samples are presented in parentheses.