Literature DB >> 25994317

Through the years with on-a-chip gas chromatography: a review.

F Haghighi1, Z Talebpour, A Sanati-Nezhad.   

Abstract

In recent years, the need for measurement and detection of samples in situ or with very small volume and low concentration (low and sub-parts per billion) is a cause for miniaturizing systems via microelectromechanical system (MEMS) technology. Gas chromatography (GC) is a common technique that is widely used for separating and measuring semi-volatile and volatile compounds. Conventional GCs are bulky and cannot be used for in situ analysis, hence in the past decades many studies have been reported with the aim of designing and developing chip-based GC. The focus of this review is to follow and investigate the development and the achievements in the field of chip-based GC and its components from the beginning up to the present.

Mesh:

Year:  2015        PMID: 25994317     DOI: 10.1039/c5lc00283d

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  6 in total

1.  Fabrication of anti-protein-fouling poly(ethylene glycol) microfluidic chip electrophoresis by sandwich photolithography.

Authors:  Hailin Cong; Xiaodan Xu; Bing Yu; Huwei Liu; Hua Yuan
Journal:  Biomicrofluidics       Date:  2016-07-19       Impact factor: 2.800

2.  Fabrication of universal serial bus flash disk type microfluidic chip electrophoresis and application for protein analysis under ultra low voltage.

Authors:  Hailin Cong; Xiaodan Xu; Bing Yu; Huwei Liu; Hua Yuan
Journal:  Biomicrofluidics       Date:  2016-03-15       Impact factor: 2.800

3.  Diagnosis of pulmonary tuberculosis and assessment of treatment response through analyses of volatile compound patterns in exhaled breath samples.

Authors:  Nicola M Zetola; Chawangwa Modongo; Ogopotse Matsiri; Tsaone Tamuhla; Bontle Mbongwe; Keikantse Matlhagela; Enoch Sepako; Alexandro Catini; Giorgio Sirugo; Eugenio Martinelli; Roberto Paolesse; Corrado Di Natale
Journal:  J Infect       Date:  2016-12-22       Impact factor: 6.072

4.  Evaluation of a portable gas chromatograph with photoionization detector under variations of VOC concentration, temperature, and relative humidity.

Authors:  Jhy-Charm Soo; Eun Gyung Lee; Ryan F LeBouf; Michael L Kashon; William Chisholm; Martin Harper
Journal:  J Occup Environ Hyg       Date:  2018-04       Impact factor: 2.155

5.  Aero-Thermo-Dynamic Mass Analysis.

Authors:  Kota Shiba; Genki Yoshikawa
Journal:  Sci Rep       Date:  2016-07-14       Impact factor: 4.379

Review 6.  Fiber Optic Gas Sensors Based on Lossy Mode Resonances and Sensing Materials Used Therefor: A Comprehensive Review.

Authors:  Ignacio Vitoria; Carlos Ruiz Zamarreño; Aritz Ozcariz; Ignacio R Matias
Journal:  Sensors (Basel)       Date:  2021-01-22       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.