Literature DB >> 25991716

A new alternative to expandable pedicle screws: Expandable poly-ether-ether-ketone shell.

Teyfik Demir1.   

Abstract

Screw pullout is a very common problem in the fixation of sacrum with pedicle screws. The principal cause of this problem is that the cyclic micro motions in the fixation of sacrum are higher than the other regions of the vertebrae that limit the osteo-integration between bone and screw. In addition to that, the bone quality is very poor at sacrum region. This study investigated a possible solution to the pullout problem without the expandable screws' handicaps. Newly designed poly-ether-ether-ketone expandable shell and classical pedicle screws were biomechanically compared. Torsion test, pullout tests, fatigue tests, flexion/extension moment test, axial gripping capacity tests and torsional gripping capacity tests were conducted in accordance with ASTM F543, F1798 and F1717. Standard polyurethane foam and calf vertebrae were used as embedding medium for pullout tests. Classical pedicle screw pullout load on polyurethane foam was 564.8 N compared to the failure load for calf vertebrae's 1264 N. Under the same test conditions, expandable poly-ether-ether-ketone shell system's pullout loads from polyurethane foam and calf vertebrae were 1196.3 and 1890 N, respectively. The pullout values for expandable poly-ether-ether-ketone shell were 33% and 53% higher than classical pedicle screw on polyurethane foam and calf vertebrae, respectively. The expandable poly-ether-ether-ketone shell exhibited endurance on its 90% of yield load. Contrary to poly-ether-ether-ketone shell, classical pedicle screw exhibited endurance on 70% of its yield load. Expandable poly-ether-ether-ketone shell exhibited much higher pullout performance than classical pedicle screw. Fatigue performance of expandable poly-ether-ether-ketone shell is also higher than classical pedicle screw due to damping the micro motion capacity of the poly-ether-ether-ketone. Expandable poly-ether-ether-ketone shell is a safe alternative to all other expandable pedicle screw systems on mechanical perspective. © IMechE 2015.

Entities:  

Keywords:  Pedicle screw; expandable poly-ether-ether-ketone shell and fatigue; pullout

Mesh:

Substances:

Year:  2015        PMID: 25991716     DOI: 10.1177/0954411915584430

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  4 in total

1.  Application value of expansive pedicle screw in the lumbar short-segment fixation and fusion for osteoporosis patients.

Authors:  Fengbiao Weng; Jiazi Wang; Liwen Yang; Jincai Zeng; Yawei Chu; Zhigang Tian
Journal:  Exp Ther Med       Date:  2018-06-01       Impact factor: 2.447

2.  How to improve the safety of bicortical pedicle screw insertion in the thoracolumbar vertebrae: analysis base on three-dimensional CT reconstruction of patients in the prone position.

Authors:  Chao Xu; Qingxian Hou; Yanchen Chu; Xiuling Huang; Wenjiu Yang; Jinglong Ma; Zhijie Wang
Journal:  BMC Musculoskelet Disord       Date:  2020-07-07       Impact factor: 2.362

3.  Pullout Strength Predictor: A Machine Learning Approach.

Authors:  Ravi Khatri; Vicky Varghese; Sunil Sharma; Gurunathan Saravana Kumar; Harvinder Singh Chhabra
Journal:  Asian Spine J       Date:  2019-06-03

4.  Effects of the Insertion Type and Depth on the Pedicle Screw Pullout Strength: A Finite Element Study.

Authors:  K Jendoubi; Y Khadri; M Bendjaballah; N Slimane
Journal:  Appl Bionics Biomech       Date:  2018-07-26       Impact factor: 1.781