Literature DB >> 25991392

Dynamic four-dimensional computed tomography (4D CT) imaging for re-entry risk assessment in re-do sternotomy - first experience.

Harish Narayanan1, Fabiano F Viana2, Julian A Smith2, Nicholas K Roumeliotis3, Christopher J Troupis4, Marcus P Crossett5, John M Troupis6.   

Abstract

BACKGROUND: Repeat cardiac surgeries are well known to have higher rates of complications, one of the important reasons being injuries associated with re-do sternotomy. Routine imaging with CT can help to minimise this risk by pre-operatively assessing the anatomical relation between the sternum and the underlying cardiovascular structures, but is limited by its inability to determine the presence and severity of functional tethering and adhesions between these structures. However, with the evolution of wide area detector MD CT scanners, it is possible to assess the presence of tethering using the dynamic four-dimensional CT (4D CT) imaging technique.
METHODS: Nineteen patients undergoing re-do cardiac surgery were pre-operatively imaged using dynamic 4D CT during regulated respiration. The datasets were assessed in cine mode for presence of differential motion between sternum and underlying cardiovascular structures which indicates lack of significant tethering.
RESULTS: Overall, there was excellent correlation between preoperative imaging and intraoperative findings. The technique enabled our surgeons to meticulously plan the procedures and to avoid re-entry related injuries.
CONCLUSIONS: Our initial experience shows that dynamic 4D CT is useful in risk stratification prior to re-do sternotomy by determining the presence or absence of tethering between sternum and underlying structures based on assessment of differential motion. Furthermore we determined the technique to be superior to non-dynamic assessment of retrocardiac tethering.
Copyright © 2015 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Differential motion; Dynamic CT; Four-dimensional CT; Re-do sternotomy; Wide area detector CT

Mesh:

Year:  2015        PMID: 25991392     DOI: 10.1016/j.hlc.2015.02.027

Source DB:  PubMed          Journal:  Heart Lung Circ        ISSN: 1443-9506            Impact factor:   2.975


  1 in total

1.  Feasibility of real-time cine cardiac magnetic resonance imaging to predict the presence of significant retrosternal adhesions prior to redo-sternotomy.

Authors:  Riad Abou Zahr; Vasu Gooty; Animesh Tandon; Gerald Greil; Timothy Pirolli; Ryan Davies; Robert Jaquiss; Claudio Ramaciotti; Tarique Hussain
Journal:  J Cardiovasc Magn Reson       Date:  2019-10-31       Impact factor: 5.364

  1 in total