| Literature DB >> 25987523 |
Salvatore Gueli Alletti1, Cristiano Rossitto2, Francesco Fanfani2, Anna Fagotti3, Barbara Costantini2, Stefano Gidaro4, Giorgia Monterossi2, Luigi Selvaggi2, Giovanni Scambia2.
Abstract
This prospective single-institutional clinical trial sought to assess the safety and feasibility of laparoscopic benign ovarian cyst enucleation with a novel robotic-assisted laparoscopic system. Here we report a series of 10 patients treated using the Telelap ALF-X system in the first clinical application on patients at the Division of Gynecologic Oncology, Catholic University of the Sacred Heart of Rome. The primary inclusion criterion was the presence of monolateral ovarian cyst without a preoperative assessment suspicious for malignancy. Intraoperative data, including docking time, operative time, estimated blood loss, intraoperative and perioperative complications, and conversion to either standard laparoscopy or laparotomy, were collected. The cysts were removed with an ovary-sparing technique with respect to conservative surgical principles. The median operative time was 46.3 minutes, and patients without postoperative complications were discharged at 1 or 2 days after the procedure. Telelap ALF-X laparoscopic enucleation of benign ovarian cysts with an ovary-sparing technique is feasible, safe, and effective; however, more clinical data are needed to determine whether this approach can offer any other benefits over other minimally invasive surgical techniques.Entities:
Keywords: Ovarian cyst; Robotic surgery; Telelap ALF-X
Mesh:
Year: 2015 PMID: 25987523 DOI: 10.1016/j.jmig.2015.05.007
Source DB: PubMed Journal: J Minim Invasive Gynecol ISSN: 1553-4650 Impact factor: 4.137