| Literature DB >> 25984475 |
Parvin Mirzakoucheki1, Ricardo Walter2, Navid Khalighinejad3, Maryam Zare Jahromi4, Sanaz Mirsattari1, Navid Akbarzadeh5.
Abstract
OBJECTIVES: The aim of this study was to evaluate the effects of tri-antibiotic paste (TAP) on microtensile bond strengths (MTBS) of dental adhesives to dentin.Entities:
Keywords: Dentin; Etch-and-rinse adhesive; Microtensile bond strength; Self-etch adhesive
Year: 2015 PMID: 25984475 PMCID: PMC4432256 DOI: 10.5395/rde.2015.40.2.136
Source DB: PubMed Journal: Restor Dent Endod ISSN: 2234-7658
Figure 1Flow chart of the experimental groups and procedures.
Materials used in the study
| Material | Category | Product | Composition |
|---|---|---|---|
| Composite resin | Silorane composite resin | Filtek P90 (3M ESPE) | Silorane resin, fine quartz and radiopaque yttrium fluoride |
| Methacrylate composite resin | Filtek Z350 (3M ESPE) | BisGMA, TEGDMA, UDMA, silica nanofillers | |
| Bonding system | Self-etch adhesive | Filtek P90 adhesive (3M ESPE) | Primer: Phosphorylated methacrylate, Vitrebond copolymer, bisGMA, HEMA, water, ethanol, silane-treated silica filler, initiator |
| Bondind resin: Hydrophobic dimethacrylate, phosphorylated methacrylates, TEGDMA, silane-treated silica filler, initiators, stabilizers | |||
| Etch-and-rinse adhesive | Adper Single Bond Plus (3M ESPE) | Etchant: 35% phosphoric acid gel | |
| Adhesive: Dimethacrylates, HEMA, polyalkenoid acid copolymer, 5 nm silane treated colloidal silica, ethanol, water, photoinitiator |
BisGMA, Bisphenol A-glycidyl methacrylate; TEGDMA, Triethyleneglycol-dimethacrylate; UDMA, Urethane dimethacrylate; HEMA, Hydroxylethyl methacrylate.
Figure 2Schematic diagram of the specimen preparation for the microtensile bond strength test. (a) Tooth decoronation below the cementoenamel junction; (b) Preparation of a flat dentin surface for bonding; (c) Dentin treatment; (d) Adhesive application; (e) Incremental resin composite buildup; (f) Cutting slab from the center of a bonded specimen after 24 h water storage; (g) A single slab containing the resin-dentin interface; (H) Beams for testing from the center slab; (i) attachment of a beam for bond strength evaluation. TAP, tri-antibiotic paste.
Mean microtensile bond strength values and standard deviations expressed in MPa of different adhesive systems for experimental and control groups (n = 30)
| Adhesive system | Control group | TAP-treated group |
|---|---|---|
| Adper Single Bond Plus + Filtek Z350 | 37.5 ± 4.2a | 35.8 ± 4.5a |
| Filtek P90 system | 27.0 ± 5.6b | 21.1 ± 4.6c |
TAP, tri-antibiotic paste.
Mode of failure of adhesive systems bonded to saline- (control) and TAP-treated dentin (n = 30)
| Failure mode | Adper Single Bond Plus | Filtek P90 adhesive | ||
|---|---|---|---|---|
| Control group | TAP-treated group | Control group | TAP-treated group | |
| Adhesive | 3 | 3 | 6 | 14 |
| Cohesive | 17 | 16 | 12 | 9 |
| Mixed | 10 | 11 | 12 | 7 |
Adhesive, adhesive (interface) failure between adhesive and dentin; Cohesive, cohesive failure in composite resin or dentin; Mixed, mixed failure of adhesive and cohesive failures.
TAP, tri-antibiotic paste.