Literature DB >> 25983598

Heart Rate Unreliability during Interval Training Recovery in Middle Distance Runners.

Filippo Tocco1, Irene Sanna1, Gabriele Mulliri1, Sara Magnani1, Francesco Todde1, Roberto Mura1, Giovanna Ghiani1, Alberto Concu2, Franco Melis1, Antonio Crisafulli1.   

Abstract

Heart rate (HR) was tested as a reliable index for recovery management during interval training (IT), considering its relationship with the several factors involved in respiratory, metabolic and cardiovascular homeostasis. Thirteen runners underwent two different IT sessions: at 80% and 120% of the second ventilatory threshold (VT2). Throughout both sessions HR, oxygen uptake (VO2), carbon dioxide production (VCO2) and pulmonary ventilation (VE), were measured by means of a portable gas analyzer. Carbon dioxide production excess (CO2excess), respiratory exchange ratio (RER), oxygen pulse (OP) and oxygen debt (O2debt) were also estimated. A significant increase in HR values (144 versus 150 beats·min(-1) between the first recovery and the last, p < 0.001) was observed at 80% of the VT2 speed. At the over-threshold intensity, HR rose from 159 to 168 beats·min(-1) from the first recovery to the last (p < 0.001). OP showed a declining trend from the first to the last recovery at 80% at the VT2 speed (18.3 versus 16.4 mL·beats(-1), p < 0.05) and between the first and the last recovery in tests performed at 120% of the VT2 speed (17.8 versus 16.3 mL·beats(-1), p < 0.05). No change occurred in CO2excess, VO2, RER, VE and O2debt. On the basis of our research, the use of fixed HR as a reliable index of the established recovery is inaccurate and unfit for training. The phenomenon of cardiac drift to set the restart timing after the repetitions, i.e. by progressively increasing HR values, should be taken into account by coaches. Key pointsDuring an IT session, if recovery time after repetitions is fixed, HR supplies a different indication compared to all the respiratory parameters: HR indicates an incomplete recovery while the other parameters do not.The use of fixed HR values as a reliable index of the established recovery during IT is inaccurate and it may be the cause of under-training.To set the restart timing after repetitions the phenomenon of cardiac drift should be taken into account by coaches.HR drift during recoveries did not appear linked to the CO2excess.

Entities:  

Keywords:  Carbon dioxide excess; oxygen debt; oxygen pulse

Year:  2015        PMID: 25983598      PMCID: PMC4424478     

Source DB:  PubMed          Journal:  J Sports Sci Med        ISSN: 1303-2968            Impact factor:   2.988


  27 in total

1.  Increase characteristics of the cumulated excess-CO2 and the lactate concentration during exercise.

Authors:  K Roecker; F Mayer; H Striegel; H H Dickhuth
Journal:  Int J Sports Med       Date:  2000-08       Impact factor: 3.118

Review 2.  Using recovery modalities between training sessions in elite athletes: does it help?

Authors:  Anthony Barnett
Journal:  Sports Med       Date:  2006       Impact factor: 11.136

3.  Aerobic high-intensity intervals improve VO2max more than moderate training.

Authors:  Jan Helgerud; Kjetill Høydal; Eivind Wang; Trine Karlsen; Pålr Berg; Marius Bjerkaas; Thomas Simonsen; Cecilies Helgesen; Ninal Hjorth; Ragnhild Bach; Jan Hoff
Journal:  Med Sci Sports Exerc       Date:  2007-04       Impact factor: 5.411

4.  Postexercise heart rate recovery accelerates in strength-trained athletes.

Authors:  Takeshi Otsuki; Seiji Maeda; Motoyuki Iemitsu; Yoko Saito; Yuko Tanimura; Jun Sugawara; Ryuichi Ajisaka; Takashi Miyauchi
Journal:  Med Sci Sports Exerc       Date:  2007-02       Impact factor: 5.411

5.  Dehydration markedly impairs cardiovascular function in hyperthermic endurance athletes during exercise.

Authors:  J González-Alonso; R Mora-Rodríguez; P R Below; E F Coyle
Journal:  J Appl Physiol (1985)       Date:  1997-04

Review 6.  Human cardiovascular adjustments to exercise and thermal stress.

Authors:  L B Rowell
Journal:  Physiol Rev       Date:  1974-01       Impact factor: 37.312

7.  Circulatory and respiratory adaptation during prolonged exercise.

Authors:  L G Ekelund
Journal:  Acta Physiol Scand Suppl       Date:  1967

8.  A theoretical approach to excessive CO2 expiration due to lactate production in exercise.

Authors:  T Yano
Journal:  Jpn J Physiol       Date:  1987

9.  Poor reliability of heart rate monitoring to assess oxygen uptake during field training.

Authors:  A Crisafulli; G Pittau; L Lorrai; A M Carcassi; M Cominu; F Tocco; F Melis; A Concu
Journal:  Int J Sports Med       Date:  2006-01       Impact factor: 3.118

10.  Bicarbonate buffering of lactic acid generated during exercise.

Authors:  W L Beaver; K Wasserman; B J Whipp
Journal:  J Appl Physiol (1985)       Date:  1986-02
View more
  3 in total

1.  Cardio-metabolic responses during horse riding at three different speeds.

Authors:  Gianmarco Sainas; Salvatore Melis; Francesco Corona; Andrea Loi; Giovanna Ghiani; Raffaele Milia; Filippo Tocco; Elisabetta Marongiu; Antonio Crisafulli
Journal:  Eur J Appl Physiol       Date:  2016-08-02       Impact factor: 3.078

2.  Physical Capacity and Energy Expenditure of Cavers.

Authors:  Virginia Pinna; Sara Magnani; Gianmarco Sainas; Giovanna Ghiani; Samuele Vanni; Sergio Olla; Elisabetta Marini; Nicoletta Curreli; Stefano Cabras; Paulo Farinatti; Giorgia Antoni; Filippo Tocco; Andrea C Rinaldi; Antonio Crisafulli
Journal:  Front Physiol       Date:  2017-12-15       Impact factor: 4.566

3.  Validity and Reliability of the Apple Watch for Measuring Heart Rate During Exercise.

Authors:  Alaa Khushhal; Simon Nichols; Will Evans; Damien O Gleadall-Siddall; Richard Page; Alasdair F O'Doherty; Sean Carroll; Lee Ingle; Grant Abt
Journal:  Sports Med Int Open       Date:  2017-10-18
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.