Optimization of insulin pump therapy based on high order run-to-run control scheme.

Jianyong Tuo1, Huiling Sun1, Dong Shen1, Hui Wang1, Youqing Wang2.   

Abstract

BACKGROUND AND OBJECTIVES: Continuous subcutaneous insulin infusion (CSII) pump is widely considered a convenience and promising way for type 1 diabetes mellitus (T1DM) subjects, who need exogenous insulin infusion. In the standard insulin pump therapy, there are two modes for insulin infusion: basal and bolus insulin. The basal-bolus therapy should be individualized and optimized in order to keep one subject's blood glucose (BG) level within the normal range; however, the optimization procedure is troublesome and it perturb the patients a lot. Therefore, an automatic adjustment method is needed to reduce the burden of the patients, and run-to-run (R2R) control algorithm can be used to handle this significant task.
METHODS: In this study, two kinds of high order R2R control methods are presented to adjust the basal and bolus insulin simultaneously. For clarity, a second order R2R control algorithm is first derived and studied. Furthermore, considering the differences between weekdays and weekends, a seventh order R2R control algorithm is also proposed and tested.
RESULTS: In order to simulate real situation, the proposed method has been tested with uncertainties on measurement noise, drifts, meal size, meal time and snack. The proposed method can converge even when there are ±60 min random variations in meal timing or ±50% random variations in meal size.
CONCLUSIONS: According to the robustness analysis, one can see that the proposed high order R2R has excellent robustness and could be a promising candidate to optimize insulin pump therapy.
Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Glucose regulation; High order run-to-run control; Type 1 diabetes mellitus

Mesh:

Substances:

Year:  2015        PMID: 25981797     DOI: 10.1016/j.cmpb.2015.04.010

Source DB:  PubMed          Journal:  Comput Methods Programs Biomed        ISSN: 0169-2607            Impact factor:   5.428


  5 in total

Review 1.  Bolus Advisors: Sources of Error, Targets for Improvement.

Authors:  John Walsh; Ruth Roberts; Timothy S Bailey; Lutz Heinemann
Journal:  J Diabetes Sci Technol       Date:  2017-07-25

2.  Continuous Glucose Monitoring and Insulin Informed Advisory System with Automated Titration and Dosing of Insulin Reduces Glucose Variability in Type 1 Diabetes Mellitus.

Authors:  Marc D Breton; Stephen D Patek; Dayu Lv; Elaine Schertz; Jessica Robic; Jennifer Pinnata; Laura Kollar; Charlotte Barnett; Christian Wakeman; Mary Oliveri; Chiara Fabris; Daniel Chernavvsky; Boris P Kovatchev; Stacey M Anderson
Journal:  Diabetes Technol Ther       Date:  2018-07-06       Impact factor: 6.118

3.  Automatic Adaptation of Basal Insulin Using Sensor-Augmented Pump Therapy.

Authors:  Pau Herrero; Jorge Bondia; Marga Giménez; Nick Oliver; Pantelis Georgiou
Journal:  J Diabetes Sci Technol       Date:  2018-03

4.  Enhancing automatic closed-loop glucose control in type 1 diabetes with an adaptive meal bolus calculator - in silico evaluation under intra-day variability.

Authors:  Pau Herrero; Jorge Bondia; Oloruntoba Adewuyi; Peter Pesl; Mohamed El-Sharkawy; Monika Reddy; Chris Toumazou; Nick Oliver; Pantelis Georgiou
Journal:  Comput Methods Programs Biomed       Date:  2017-06-01       Impact factor: 5.428

5.  Continuous Glucose Monitors and Activity Trackers to Inform Insulin Dosing in Type 1 Diabetes: The University of Virginia Contribution.

Authors:  Chiara Fabris; Basak Ozaslan; Marc D Breton
Journal:  Sensors (Basel)       Date:  2019-12-06       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.