Literature DB >> 25979883

Reaerosolization of Spores from Flooring Surfaces To Assess the Risk of Dissemination and Transmission of Infections.

Susan Paton1, Katy-Anne Thompson2, Simon R Parks2, Allan M Bennett2.   

Abstract

The aim of this study was to quantify reaerosolization of microorganisms caused by walking on contaminated flooring to assess the risk to individuals accessing areas contaminated with pathogenic organisms, for example, spores of Bacillus anthracis. Industrial carpet and polyvinyl chloride (PVC) floor coverings were contaminated with aerosolized spores of Bacillus atrophaeus by using an artist airbrush to produce deposition of ∼10(3) to 10(4) CFU · cm(-2). Microbiological air samplers were used to quantify the particle size distribution of the aerosol generated when a person walked over the floorings in an environmental chamber. Results were expressed as reaerosolization factors (percent per square centimeter per liter), to represent the ratio of air concentration to surface concentration generated. Walking on carpet generated a statistically significantly higher reaerosolization factor value than did walking on PVC (t = 20.42; P < 0.001). Heavier walking produced a statistically significantly higher reaerosolization factor value than did lighter walking (t = 12.421; P < 0.001). Height also had a statistically significant effect on the reaerosolization factor, with higher rates of recovery of B. atrophaeus at lower levels, demonstrating a height-dependent gradient of particle reaerosolization. Particles in the respirable size range were recovered in all sampling scenarios (mass mean diameters ranged from 2.6 to 4.1 μm). The results of this study can be used to produce a risk assessment of the potential aerosol exposure of a person accessing areas with contaminated flooring in order to inform the choice of appropriate respiratory protective equipment and may aid in the selection of the most suitable flooring types for use in health care environments, to reduce aerosol transmission in the event of contamination.
Copyright © 2015, American Society for Microbiology. All Rights Reserved.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25979883      PMCID: PMC4495222          DOI: 10.1128/AEM.00412-15

Source DB:  PubMed          Journal:  Appl Environ Microbiol        ISSN: 0099-2240            Impact factor:   4.792


  14 in total

1.  Monitoring personal fine particle exposure with a particle counter.

Authors:  M Brauer; R D Hirtle; A C Hall; T R Yip
Journal:  J Expo Anal Environ Epidemiol       Date:  1999 May-Jun

2.  Characterization of indoor particle sources using continuous mass and size monitors.

Authors:  C M Long; H H Suh; P Koutrakis
Journal:  J Air Waste Manag Assoc       Date:  2000-07       Impact factor: 2.235

3.  Microbiological contamination of hospital air. I. Quantitative studies.

Authors:  V W GREENE; D VESLEY; R G BOND; G S MICHAELSEN
Journal:  Appl Microbiol       Date:  1962-11

4.  New sampler for the collection, sizing, and enumeration of viable airborne particles.

Authors:  A A ANDERSEN
Journal:  J Bacteriol       Date:  1958-11       Impact factor: 3.490

5.  Elevated personal exposure to particulate matter from human activities in a residence.

Authors:  Andrea R Ferro; Royal J Kopperud; Lynn M Hildemann
Journal:  J Expo Anal Environ Epidemiol       Date:  2004

Review 6.  Indoor particles: a review.

Authors:  L Wallace
Journal:  J Air Waste Manag Assoc       Date:  1996-02       Impact factor: 2.235

7.  An assessment of the Sartorius MD8 microbiological air sampler.

Authors:  S R Parks; A M Bennett; S E Speight; J E Benbough
Journal:  J Appl Bacteriol       Date:  1996-05

8.  Bacterial air counts obtained with a centrifugal (RCS) sampler and a slit sampler--the influence of aerosols.

Authors:  M W Casewell; P G Fermie; C Thomas; N A Simmons
Journal:  J Hosp Infect       Date:  1984-03       Impact factor: 3.926

9.  Biological evaluation of carpeting.

Authors:  R L Anderson
Journal:  Appl Microbiol       Date:  1969-08

Review 10.  How long do nosocomial pathogens persist on inanimate surfaces? A systematic review.

Authors:  Axel Kramer; Ingeborg Schwebke; Günter Kampf
Journal:  BMC Infect Dis       Date:  2006-08-16       Impact factor: 3.090

View more
  3 in total

Review 1.  Mechanisms for floor surfaces or environmental ground contamination to cause human infection: a systematic review.

Authors:  T Rashid; H Vonville; I Hasan; K W Garey
Journal:  Epidemiol Infect       Date:  2016-10-26       Impact factor: 4.434

Review 2.  Do Carpets Impair Indoor Air Quality and Cause Adverse Health Outcomes: A Review.

Authors:  Rune Becher; Johan Øvrevik; Per E Schwarze; Steinar Nilsen; Jan K Hongslo; Jan Vilhelm Bakke
Journal:  Int J Environ Res Public Health       Date:  2018-01-23       Impact factor: 3.390

3.  Ten questions concerning the implications of carpet on indoor chemistry and microbiology.

Authors:  Sarah R Haines; Rachel I Adams; Brandon E Boor; Thomas A Bruton; John Downey; Andrea R Ferro; Elliott Gall; Brett J Green; Bridget Hegarty; Elliott Horner; David E Jacobs; Paul Lemieux; Pawel K Misztal; Glenn Morrison; Matthew Perzanowski; Tiina Reponen; Rachael E Rush; Troy Virgo; Celine Alkhayri; Ashleigh Bope; Samuel Cochran; Jennie Cox; Allie Donohue; Andrew A May; Nicholas Nastasi; Marcia Nishioka; Nicole Renninger; Yilin Tian; Christina Uebel-Niemeier; David Wilkinson; Tianren Wu; Jordan Zambrana; Karen C Dannemiller
Journal:  Build Environ       Date:  2019-12-18       Impact factor: 6.456

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.