Literature DB >> 25979053

Treatment planning for radiotherapy with very high-energy electron beams and comparison of VHEE and VMAT plans.

Magdalena Bazalova-Carter1, Bradley Qu1, Bianey Palma1, Björn Hårdemark2, Elin Hynning2, Christopher Jensen1, Peter G Maxim1, Billy W Loo1.   

Abstract

PURPOSE: The aim of this work was to develop a treatment planning workflow for rapid radiotherapy delivered with very high-energy electron (VHEE) scanning pencil beams of 60-120 MeV and to study VHEE plans as a function of VHEE treatment parameters. Additionally, VHEE plans were compared to clinical state-of-the-art volumetric modulated arc therapy (VMAT) photon plans for three cases.
METHODS: VHEE radiotherapy treatment planning was performed by linking EGSnrc Monte Carlo (MC) dose calculations with inverse treatment planning in a research version of RayStation. In order to study the effect of VHEE treatment parameters on VHEE dose distributions, a matlab graphical user interface (GUI) for calculation of VHEE MC pencil beam doses was developed. Through the GUI, pediatric case MC simulations were run for a number of beam energies (60, 80, 100, and 120 MeV), number of beams (13, 17, and 36), pencil beam spot (0.1, 1.0, and 3.0 mm) and grid (2.0, 2.5, and 3.5 mm) sizes, and source-to-axis distance, SAD (40 and 50 cm). VHEE plans for the pediatric case calculated with the different treatment parameters were optimized and compared. Furthermore, 100 MeV VHEE plans for the pediatric case, a lung, and a prostate case were calculated and compared to the clinically delivered VMAT plans. All plans were normalized such that the 100% isodose line covered 95% of the target volume.
RESULTS: VHEE beam energy had the largest effect on the quality of dose distributions of the pediatric case. For the same target dose, the mean doses to organs at risk (OARs) decreased by 5%-16% when planned with 100 MeV compared to 60 MeV, but there was no further improvement in the 120 MeV plan. VHEE plans calculated with 36 beams outperformed plans calculated with 13 and 17 beams, but to a more modest degree (<8%). While pencil beam spacing and SAD had a small effect on VHEE dose distributions, 0.1-3 mm pencil beam sizes resulted in identical dose distributions. For the 100 MeV VHEE pediatric plan, OAR doses were up to 70% lower and the integral dose was 33% lower for VHEE compared to 6 MV VMAT. Additionally, VHEE conformity indices (CI100 = 1.09 and CI50 = 4.07) were better than VMAT conformity indices (CI100 = 1.30 and CI50 = 6.81). The 100 MeV VHEE lung plan resulted in mean dose decrease to all OARs by up to 27% for the same target coverage compared to the clinical 6 MV flattening filter-free (FFF) VMAT plan. The 100 MeV prostate plan resulted in 3% mean dose increase to the penile bulb and the urethra, but all other OAR mean doses were lower compared to the 15 MV VMAT plan. The lung case CI100 and CI50 conformity indices were 3% and 8% lower, respectively, in the VHEE plan compared to the VMAT plan. The prostate case CI100 and CI50 conformity indices were 1% higher and 8% lower, respectively, in the VHEE plan compared to the VMAT plan.
CONCLUSIONS: The authors have developed a treatment planning workflow for MC dose calculation of pencil beams and optimization for treatment planning of VHEE radiotherapy. The authors have demonstrated that VHEE plans resulted in similar or superior dose distributions for pediatric, lung, and prostate cases compared to clinical VMAT plans.

Entities:  

Mesh:

Year:  2015        PMID: 25979053     DOI: 10.1118/1.4918923

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  11 in total

1.  Optimization of an on-board imaging system for extremely rapid radiation therapy.

Authors:  Erica M Cherry Kemmerling; Meng Wu; He Yang; Peter G Maxim; Billy W Loo; Rebecca Fahrig
Journal:  Med Phys       Date:  2015-11       Impact factor: 4.071

Review 2.  Ultra-high dose rate electron beams and the FLASH effect: From preclinical evidence to a new radiotherapy paradigm.

Authors:  Emil Schüler; Munjal Acharya; Pierre Montay-Gruel; Billy W Loo; Marie-Catherine Vozenin; Peter G Maxim
Journal:  Med Phys       Date:  2022-01-19       Impact factor: 4.506

3.  Initial Steps Towards a Clinical FLASH Radiotherapy System: Pediatric Whole Brain Irradiation with 40 MeV Electrons at FLASH Dose Rates.

Authors:  Dylan Yamabe Breitkreutz; Muhammad Shumail; Karl K Bush; Sami G Tantawi; Peter G Maxime; Billy W Loo
Journal:  Radiat Res       Date:  2020-12-01       Impact factor: 2.841

4.  The challenge of ionisation chamber dosimetry in ultra-short pulsed high dose-rate Very High Energy Electron beams.

Authors:  M McManus; F Romano; N D Lee; W Farabolini; A Gilardi; G Royle; H Palmans; A Subiel
Journal:  Sci Rep       Date:  2020-06-03       Impact factor: 4.379

5.  Focused very high-energy electron beams as a novel radiotherapy modality for producing high-dose volumetric elements.

Authors:  K Kokurewicz; E Brunetti; G H Welsh; S M Wiggins; M Boyd; A Sorensen; A J Chalmers; G Schettino; A Subiel; C DesRosiers; D A Jaroszynski
Journal:  Sci Rep       Date:  2019-07-25       Impact factor: 4.379

6.  Evaluating very high energy electron RBE from nanodosimetric pBR322 plasmid DNA damage.

Authors:  K L Small; N T Henthorn; D Angal-Kalinin; A L Chadwick; E Santina; A Aitkenhead; K J Kirkby; R J Smith; M Surman; J Jones; W Farabolini; R Corsini; D Gamba; A Gilardi; M J Merchant; R M Jones
Journal:  Sci Rep       Date:  2021-02-08       Impact factor: 4.379

7.  A focused very high energy electron beam for fractionated stereotactic radiotherapy.

Authors:  Kristoffer Svendsen; Diego Guénot; Jonas Björklund Svensson; Kristoffer Petersson; Anders Persson; Olle Lundh
Journal:  Sci Rep       Date:  2021-03-12       Impact factor: 4.379

8.  Focused VHEE (very high energy electron) beams and dose delivery for radiotherapy applications.

Authors:  L Whitmore; R I Mackay; M van Herk; J K Jones; R M Jones
Journal:  Sci Rep       Date:  2021-07-07       Impact factor: 4.379

9.  Toward an effective use of laser-driven very high energy electrons for radiotherapy: Feasibility assessment of multi-field and intensity modulation irradiation schemes.

Authors:  Luca Labate; Daniele Palla; Daniele Panetta; Federico Avella; Federica Baffigi; Fernando Brandi; Fabio Di Martino; Lorenzo Fulgentini; Antonio Giulietti; Petra Köster; Davide Terzani; Paolo Tomassini; Claudio Traino; Leonida A Gizzi
Journal:  Sci Rep       Date:  2020-10-14       Impact factor: 4.379

10.  First theoretical determination of relative biological effectiveness of very high energy electrons.

Authors:  Rachel Delorme; Thongchai A M Masilela; Camille Etoh; François Smekens; Yolanda Prezado
Journal:  Sci Rep       Date:  2021-05-27       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.