| Literature DB >> 25978522 |
Dong-Uk Park1, Ye-Yong Choi2, Jong-Ju Ahn2, Heung-Kyu Lim2, Sun-Kyung Kim2, Hyun-Suk Roh3, Hae-Kwan Cheong4, Jong-Han Leem5, Dong-Hee Koh6, Hye-Jung Jung1, Kyoung-Mu Lee1, Jong-Hyeon Lee7, Yong-Hwa Kim8, Sin-Ye Lim9, Do-Myung Paek10, Chae-Man Lim11, Soo-Jong Hong12.
Abstract
BACKGROUND: In South Korea, a cluster of acute lung disease patients included lung injury disease suspected of being caused by the use of humidifier disinfectants. We examined the relationship between humidifier disinfectant exposure and clinically diagnosed humidifier disinfectant-associated lung injury (HDLI) in a family-based study.Entities:
Mesh:
Substances:
Year: 2015 PMID: 25978522 PMCID: PMC4433275 DOI: 10.1371/journal.pone.0124610
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Associations with HDLI for confounding factors.
| Classification | Cases(n = 169) | Controls(n = 303) | |||||
|---|---|---|---|---|---|---|---|
| n | % | n | % | Adj. OR | 95% CI | ||
| Gender | |||||||
| Male | 72 | 42.6 | 153 | 50.5 | 1.0 | Ref | |
| Female | 97 | 57.4 | 150 | 49.5 | 1.4 | 0.9 | 2 |
| Smoking status | |||||||
| Never | 159 | 94.1 | 220 | 72.6 | 1.0 | Ref | |
| Ever | 6 | 3.6 | 27 | 8.9 | 0.3 | 0.1 | 0.8 |
| Current | 0 | 0.0 | 51 | 16.8 | N.A. | ||
| No. of household products containing chemical used a | |||||||
| Q1(<3) | 31 | 18.3 | 55 | 18.2 | 1.0 | Ref | |
| Q2(3) | 46 | 27.2 | 89 | 29.4 | 0.8 | 0.4 | 1.6 |
| Q3(5) | 29 | 17.2 | 51 | 16.8 | 1.0 | 0.5 | 2.0 |
| Q4(6) | 63 | 37.3 | 108 | 35.6 | 1.0 | 0.5 | 1.8 |
| Presence of factory within 1 km of residence a | |||||||
| No | 163 | 96.4 | 286.0 | 94.4 | 1.0 | Ref | |
| Yes | 6 | 3.6 | 17.0 | 5.6 | 0.5 | 0.2 | 1.4 |
| Age group | |||||||
| >18 years old | 36 | 21.3 | 226 | 74.6 | 1.0 | Ref | |
| 7 through 18 years old | 4 | 2.4 | 12 | 4.0 | 3.3 | 0.7 | 15.3 |
| ≤ 6 years old | 103 | 60.9 | 56 | 18.5 | 19.4 | 5.4 | 70.1 |
| Pregnant women | 26 | 15.4 | 9 | 3.0 | 14.6 | 6.0 | 35.8 |
Note: N.A: Not Applicable
b ORs and CIs were estimated by unconditional logistic regression, adjusted for sex, no. of household products containing chemicals, and presence of a factory within 1 km of residence.
Humidifier disinfectant use characteristics by HDLI case and control and age group.
| Classification | ≤6 years old | 7–18 years old | Pregnant women | >8 years old | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Cases (n = 103) | % | Controls (n = 56) | % | Cases (n = 4) | % | Controls (n = 12) | % | Cases (n = 26) | % | Controls (n = 9) | % | Cases (n = 36) | % | Controls (n = 226) | % | |
| Total years of use, years | ||||||||||||||||
| Q1(≤0.42) | 24 | 23.3 | 13 | 23.2 | 0 | 0.0 | 3 | 25.0 | 4 | 15.4 | 2 | 22.2 | 7 | 19.4 | 47 | 20.8 |
| Q2(0.43–2.25) | 28 | 27.2 | 15 | 26.8 | 0 | 0.0 | 1 | 8.3 | 8 | 30.8 | 3 | 33.3 | 7 | 19.4 | 53 | 23.5 |
| Q3(2.26–3.25) | 28 | 27.2 | 13 | 23.2 | 3 | 75.0 | 3 | 25.0 | 4 | 15.4 | 1 | 11.1 | 4 | 11.1 | 57 | 25.2 |
| Q4(3.26–4) | 20 | 19.4 | 14 | 25.0 | 1 | 25.0 | 5 | 41.7 | 10 | 38.5 | 3 | 33.3 | 18 | 50.0 | 68 | 30.1 |
| P-value | 0.126 | 0.371 | 0.297 | 0.146 | ||||||||||||
| Average total months of use per year, months | ||||||||||||||||
| Q1(≤3) | 5 | 4.9 | 2 | 3.6 | 0.0 | 0.0 | 0 | 0.0 | 1 | 11.1 | 0 | 0.0 | 14 | 6.2 | ||
| Q2(4–6) | 48 | 46.6 | 20 | 35.7 | 2 | 50.0 | 3 | 25.0 | 13 | 50.0 | 3 | 33.3 | 15 | 41.7 | 88 | 38.9 |
| Q3(7–9) | 19 | 18.4 | 13 | 23.2 | 2 | 50.0 | 1 | 8.3 | 9 | 34.6 | 3 | 33.3 | 7 | 19.4 | 44 | 19.5 |
| Q4(10–12) | 31 | 30.1 | 21 | 37.5 | 0 | 0.0 | 8 | 66.7 | 4 | 15.4 | 2 | 22.2 | 14 | 38.9 | 80 | 35.4 |
| P-value | 0.13 | 0.218 | 0.126 | |||||||||||||
| Average total use hours per day, hours | ||||||||||||||||
| Q1(≤10) | 11 | 10.7 | 10 | 17.9 | 1 | 25.0 | 2 | 16.7 | 5 | 19.2 | 3 | 33.3 | 5 | 13.9 | 51 | 22.6 |
| Q2(11–12) | 26 | 25.2 | 15 | 26.8 | 3 | 75.0 | 4 | 33.3 | 9 | 34.6 | 2 | 22.2 | 8 | 22.2 | 56 | 24.8 |
| Q3(13–14) | 37 | 35.9 | 15 | 26.8 | 0 | 0.0 | 3 | 25.0 | 4 | 15.4 | 3 | 33.3 | 8 | 22.2 | 59 | 26.1 |
| Q4(15–24) | 27 | 26.2 | 16 | 28.6 | 0 | 0.0 | 3 | 25.0 | 8 | 30.8 | 1 | 11.1 | 15 | 41.7 | 60 | 26.5 |
| P-value | 0.129 | 0.26 | 0.266 | 0.0 | 0.133 | |||||||||||
| Average hours sleeping in a room with an operating humidifier treated with disinfectant per day, hrs | ||||||||||||||||
| Q1(≤10) | 16 | 15.5 | 14 | 25.0 | 1 | 25.0 | 3 | 25.0 | 7 | 26.9 | 3 | 33.3 | 5 | 13.9 | 65 | 28.8 |
| Q2(10.1–11) | 21 | 20.4 | 12 | 21.4 | 3 | 75.0 | 5 | 41.7 | 4 | 15.4 | 2 | 22.2 | 7 | 19.4 | 48 | 21.2 |
| Q3(11.1–12) | 64 | 62.1 | 30 | 53.6 | 0 | 0.0 | 4 | 33.3 | 15 | 57.7 | 4 | 44.4 | 24 | 66.7 | 113 | 50.0 |
| P-value | 0.143 | 0.36 | 0.312 | 0.118 | ||||||||||||
| Type of disinfectant | ||||||||||||||||
| Non-Guanidine | 2 | 1.9 | 3 | 5.4 | 2 | 50.0 | 0 | 0.0 | 0 | 0.0 | 1 | 11.1 | 1 | 2.8 | 27 | 11.9 |
| Guanidine | 99 | 96.1 | 51 | 91.1 | 2 | 50.0 | 11 | 91.7 | 26 | 100.0 | 8 | 88.9 | 34 | 94.4 | 194 | 85.8 |
| P-value | 0.354 | 0.012 | 0.085 | 0.298 | ||||||||||||
| No of disinfectant products used | ||||||||||||||||
| 1 | 59 | 57.3 | 33 | 58.9 | 0 | 0.0 | 5 | 41.7 | 16 | 61.5 | 5 | 55.6 | 20 | 55.6 | 136 | 60.2 |
| 2 | 33 | 32.0 | 17 | 30.4 | 3 | 75.0 | 3 | 25.0 | 8 | 30.8 | 3 | 33.3 | 9 | 25.0 | 67 | 29.6 |
| ≥ 3 | 9 | 8.7 | 4 | 7.1 | 1 | 25.0 | 3 | 25.0 | 2 | 7.7 | 1 | 11.1 | 6 | 16.7 | 17 | 7.5 |
| P-value | 0.158 | 0.326 | 0.352 | 0.168 | ||||||||||||
| Average distance of the bed apart from humidifier | ||||||||||||||||
| > 1 m | 65 | 63.1 | 52 | 92.9 | 1 | 25.0 | 10 | 83.3 | 19 | 73.1 | 8 | 88.9 | 29 | 80.6 | 186 | 82.3 |
| 0.5–1 m | 31 | 30.1 | 4 | 7.1 | 3 | 75.0 | 1 | 8.3 | 5 | 19.2 | 0 | 0.0 | 3 | 8.3 | 37 | 16.4 |
| < 0.5 | 4 | 3.9 | 0 | 0.0 | 0 | 0.0 | 1 | 8.3 | 2 | 7.7 | 1 | 11.1 | 4 | 11.1 | 2 | 0.9 |
| P-value | <0.0001 | 0.028 | 0.361 | <0.0001 | ||||||||||||
| Cumulative use hours, hours | ||||||||||||||||
| Q1(<1260) | 22 | 21.4 | 16 | 28.6 | 1 | 25.0 | 3 | 25.0 | 5 | 19.2 | 3 | 33.3 | 4 | 11.1 | 62 | 27.4 |
| Q2(1261–2352) | 33 | 32.0 | 10 | 17.9 | 2 | 50.0 | 2 | 16.7 | 5 | 19.2 | 2 | 22.2 | 6 | 16.7 | 56 | 24.8 |
| Q3(2353–5040) | 23 | 22.3 | 16 | 28.6 | 1 | 25.0 | 2 | 16.7 | 8 | 30.8 | 2 | 22.2 | 11 | 30.6 | 52 | 23.0 |
| Q4(5041–39116) | 22 | 21.4 | 14 | 25.0 | 0 | 0.0 | 5 | 41.7 | 8 | 30.8 | 2 | 22.2 | 15 | 41.7 | 54 | 23.9 |
| P-value | 0.24 | 0.375 | 0.28 | 0.036 | ||||||||||||
| Airborne disinfectant intensity, | ||||||||||||||||
| Q1(<317.1) | 18 | 17.5 | 12 | 21.4 | 2 | 50.0 | 2 | 16.7 | 9 | 34.6 | 4 | 44.4 | 6 | 16.7 | 55 | 24.3 |
| Q2(317.2–508.5) | 25 | 24.3 | 15 | 26.8 | 1 | 25.0 | 1 | 8.3 | 6 | 23.1 | 2 | 22.2 | 5 | 13.9 | 61 | 27.0 |
| Q3(508.6–942.5) | 28 | 27.2 | 16 | 28.6 | 0 | 0.0 | 6 | 50.0 | 5 | 19.2 | 3 | 33.3 | 11 | 30.6 | 43 | 19.0 |
| Q4(942.6–4946.9) | 30 | 29.1 | 10 | 17.9 | 1 | 25.0 | 2 | 16.7 | 6 | 23.1 | 0 | 0.0 | 13 | 36.1 | 51 | 22.6 |
| P-value | 0.526 | 0.27 | 0.418 | 0.074 | ||||||||||||
Note: HDLI: Humidifier disinfectant-associated lung injury.
a Cumulative disinfectant use hours were calculated by multiplying together the total years, months per year, weeks per month, days per week, and hours per day.
b Airborne disinfectant intensity was calculated by multiplying together the bulk level of humidifier disinfectant identified in the specified disinfectant brand (μg/mℓ), the average volume (mℓ) added to humidifier, and the room volume (area x height, m3).
Association between humidifier disinfectant exposure-related characteristics and HDLI risk.
| Classification | Cases (n = 169) | Controls (n = 303) | ||||||
|---|---|---|---|---|---|---|---|---|
| n | % | n | % | Adj. OR | 95% CI | P-trend | ||
| Total years of use, years | ||||||||
| Q1(<0.42) | 35 | 20.7 | 65 | 21.5 | 1.0 | Ref | ||
| Q2(0.43–2.25) | 43 | 25.4 | 72 | 23.8 | 1.0 | 0.5 | 2.1 | |
| Q3(2.26–3.25) | 39 | 23.1 | 74 | 24.4 | 0.9 | 0.5 | 1.9 | |
| Q4(3.26–4) | 49 | 29.0 | 90 | 29.7 | 1.1 | 0.6 | 2.2 | 0.64 |
| N.I. | 3 | 1.8 | 2 | 0.7 | ||||
| Average total months of use per year, months | ||||||||
| Q1(<3) | 5 | 3.0 | 17 | 5.6 | 1.0 | Ref | ||
| Q2(4–6) | 78 | 46.2 | 114 | 37.6 | 3.0 | 0.9 | 10.4 | |
| Q3(7–9) | 37 | 21.9 | 61 | 20.1 | 2.3 | 0.6 | 8.3 | |
| Q4(10–12) | 49 | 29.0 | 111 | 36.6 | 1.7 | 0.5 | 6.0 | 0.25 |
| Average total use hours per day, hours | ||||||||
| Q1(<10) | 22 | 13.0 | 66 | 21.8 | 1.0 | Ref | ||
| Q2(11–12) | 46 | 27.2 | 77 | 25.4 | 1.6 | 0.7 | 3.4 | |
| Q3(13–14) | 49 | 29.0 | 80 | 26.4 | 1.6 | 0.8 | 3.5 | |
| Q4(15–24) | 50 | 29.6 | 80 | 26.4 | 2.1 | 1.0 | 4.5 | 0.067 |
| N.I. | 2 | 1.2 | ||||||
| Average hours sleeping in a room with an operating humidifier treated with disinfectant per day, hours | ||||||||
| Q1(<10) | 29 | 17.2 | 79 | 26.1 | 1.0 | Ref | ||
| Q2(10.1–11) | 35 | 20.7 | 63 | 20.8 | 1.7 | 0.8 | 3.5 | |
| Q3(11.1–12) | 103 | 60.9 | 144 | 47.5 | 2.0 | 1.1 | 3.7 | 0.043 |
| N.I. | 2 | 1.2 | 17 | 5.6 | ||||
| Type of disinfectant | ||||||||
| Non-Guanidine | 5 | 3.0 | 31 | 10.2 | 1.0 | Ref | ||
| Guanidine | 161 | 95.3 | 264 | 87.1 | 2.6 | 0.9 | 8.0 | NS |
| N.I. | 3 | 1.8 | 8 | 2.6 | ||||
| No of disinfectant products used | ||||||||
| 1 | 95 | 56.2 | 179.0 | 59.1 | 1.0 | Ref | ||
| 2 | 53 | 31.4 | 90.0 | 29.7 | 1.2 | 0.7 | 2.1 | |
| 3 | 18 | 10.7 | 25.0 | 8.3 | 2.2 | 0.9 | 5.2 | 0.086 |
| N.I. | 3 | 1.8 | 7 | 2.3 | ||||
| Average distance of the bed apart from humidifier, meter | ||||||||
| > 1m | 114 | 67.5 | 256 | 84.5 | 1.0 | Ref | ||
| 0.5–1 m | 42 | 24.9 | 42 | 13.9 | 2.7 | 1.5 | 5.1 | |
| < 0.5 m | 10 | 5.9 | 4 | 1.3 | 13.2 | 2.4 | 73.0 | <0.0001 |
| N.I. | 3 | 1.8 | 1 | 0.3 | ||||
| Cumulative use hours, hours | ||||||||
| Q1(<1260) | 32 | 18.9 | 84 | 27.7 | 1.0 | Ref | ||
| Q2(1261–2352) | 46 | 27.2 | 70 | 23.1 | 1.4 | 0.7 | 2.8 | |
| Q3(2353–5040) | 43 | 25.4 | 72 | 23.8 | 1.6 | 0.8 | 3.2 | |
| Q4(5041–39116) | 45 | 26.6 | 75 | 24.8 | 1.5 | 0.7 | 2.9 | 0.27 |
| N.I. | 3 | 1.8 | 2 | 0.7 | ||||
| Airborne disinfectant intensity, | ||||||||
| Q1(<317.1) | 35 | 20.7 | 77 | 25.4 | 1.0 | Ref | ||
| Q2(317.2–508.5) | 36 | 21.3 | 76 | 25.1 | 1.0 | 0.5 | 1.9 | |
| Q3(508.6–942.5) | 44 | 26.0 | 67 | 22.1 | 1.2 | 0.6 | 2.4 | |
| Q4(942.6–4946.9) | 50 | 29.6 | 63 | 20.8 | 2.6 | 1.2 | 5.3 | 0.009 |
| N.I. | 4 | 2.4 | 10 | 3.3 | ||||
| Cumulative exposure level, unit-less, | ||||||||
| Q1(<512000) | 33 | 19.5 | 76 | 25.1 | 1.0 | Ref | ||
| Q2(512001–1464515) | 45 | 26.6 | 69 | 22.8 | 1.1 | 0.6 | 2.3 | |
| Q3(1464516–3928750) | 36 | 21.3 | 75 | 24.8 | 0.9 | 0.5 | 1.9 | |
| Q4(3928751-1x108) | 51 | 30.2 | 61 | 20.1 | 2.0 | 1.0 | 4.1 | 0.071 |
| N.I. | 4 | 2.4 | 22 | 7.3 | ||||
Note: HDLI: Humidifier disinfectant-associated lung injury. N.I: No information
a Cumulative disinfectant use hours were calculated by multiplying together the total years, months per year, weeks per month, days per week, and hours per day.
b Airborne disinfectant intensity was calculated by multiplying together the bulk level of humidifier disinfectant identified in the specified disinfectant brand (μg/mℓ), the average volume (mℓ) added to humidifier, and the room volume (area x height, m3).
c Cumulative exposure level = a*b.
ORs and CIs were estimated by unconditional regression, adjusted for stratification variables, age, sex, no of chemical used in house, presence of factory around house and age group.