Literature DB >> 25978443

Silicon/SU8 multi-electrode micro-needle for in vivo neurochemical monitoring.

Natalia Vasylieva1, Stéphane Marinesco2, Daniel Barbier3, Andrei Sabac4.   

Abstract

Simultaneous monitoring of glucose and lactate is an important challenge for understanding brain energetics in physiological or pathological states. We demonstrate here a versatile method based on a minimally invasive single implantation in the rat brain. A silicon/SU8-polymer multi-sensing needle-shaped biosensor, was fabricated and tested. The multi-electrode array design comprises three platinum planar microelectrodes with a surface area of 40 × 200 µm(2) and a spacing of 200 µm, which were micromachined on a single 3mm long micro-needle having a 100 × 50 µm(2) cross-section for reduced tissue damage during implantation. Platinum micro-electrodes were aligned at the bottom of micro-wells obtained by photolithography on a SU8 photoresist layer. After clean room processing, each micro-electrode was functionalized inside the micro-wells by means of a micro-dispensing device, either with glucose oxidase or with lactate oxidase, which were cross-linked on the platinum electrodes. The third electrode covered with Bovine Serum Albumin (BSA) was used for the control of non-specific currents. The thick SU8 photoresist layer has revealed excellent electrical insulation of the micro-electrodes and between interconnection lines, and ensured a precise localization and packaging of the sensing enzymes on platinum micro-electrodes. During in vitro calibration with concentrations of analytes in the mM range, the micro-wells patterned in the SU8 photoresist proved to be highly effective in eliminating cross-talk signals, caused by H2O2 diffusion from closely spaced micro-electrodes. Moreover, our biosensor was successfully assayed in the rat cortex for simultaneous monitoring of both glucose and lactate during insulin and glucose administration.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Enzymatic biosensor; Glucose; Lactate; Microfabrication; Rat brain; bioMEMS

Mesh:

Substances:

Year:  2015        PMID: 25978443     DOI: 10.1016/j.bios.2015.05.004

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  12 in total

1.  An implantable multimodal sensor for oxygen, neurotransmitters, and electrophysiology during spreading depolarization in the deep brain.

Authors:  Caddy N Hobbs; Justin A Johnson; Matthew D Verber; R Mark Wightman
Journal:  Analyst       Date:  2017-08-07       Impact factor: 4.616

2.  Direct in Vivo Electrochemical Detection of Resting Dopamine Using Poly(3,4-ethylenedioxythiophene)/Carbon Nanotube Functionalized Microelectrodes.

Authors:  Ian Mitchell Taylor; Nikita Anurag Patel; Noah Chaim Freedman; Elisa Castagnola; Xinyan Tracy Cui
Journal:  Anal Chem       Date:  2019-09-26       Impact factor: 6.986

Review 3.  Non-transdermal microneedles for advanced drug delivery.

Authors:  KangJu Lee; Marcus J Goudie; Peyton Tebon; Wujin Sun; Zhimin Luo; Junmin Lee; Shiming Zhang; Kirsten Fetah; Han-Jun Kim; Yumeng Xue; Mohammad Ali Darabi; Samad Ahadian; Einollah Sarikhani; WonHyoung Ryu; Zhen Gu; Paul S Weiss; Mehmet R Dokmeci; Nureddin Ashammakhi; Ali Khademhosseini
Journal:  Adv Drug Deliv Rev       Date:  2019-12-16       Impact factor: 15.470

4.  Rapid Makerspace Microfabrication and Characterization of 3D Microelectrode Arrays (3D MEAs) for Organ-on-a-Chip Models.

Authors:  Charles M Didier; Avra Kundu; Swaminathan Rajaraman
Journal:  J Microelectromech Syst       Date:  2021-09-15       Impact factor: 2.829

5.  Neurometabolic and electrophysiological changes during cortical spreading depolarization: multimodal approach based on a lactate-glucose dual microbiosensor arrays.

Authors:  Cátia F Lourenço; Ana Ledo; Greg A Gerhardt; João Laranjinha; Rui M Barbosa
Journal:  Sci Rep       Date:  2017-07-28       Impact factor: 4.379

6.  Coordinated Acetylcholine Release in Prefrontal Cortex and Hippocampus Is Associated with Arousal and Reward on Distinct Timescales.

Authors:  Leonor M Teles-Grilo Ruivo; Keeley L Baker; Michael W Conway; Peter J Kinsley; Gary Gilmour; Keith G Phillips; John T R Isaac; John P Lowry; Jack R Mellor
Journal:  Cell Rep       Date:  2017-01-24       Impact factor: 9.423

Review 7.  Functionalized microneedles for continuous glucose monitoring.

Authors:  Kai Takeuchi; Beomjoon Kim
Journal:  Nano Converg       Date:  2018-10-24

8.  On-Glass Integrated SU-8 Waveguide and Amorphous Silicon Photosensor for On-Chip Detection of Biomolecules: Feasibility Study on Hemoglobin Sensing.

Authors:  Alessio Buzzin; Rita Asquini; Domenico Caputo; Giampiero de Cesare
Journal:  Sensors (Basel)       Date:  2021-01-08       Impact factor: 3.576

Review 9.  Microfabricated, amperometric, enzyme-based biosensors for in vivo applications.

Authors:  Andreas Weltin; Jochen Kieninger; Gerald A Urban
Journal:  Anal Bioanal Chem       Date:  2016-03-02       Impact factor: 4.142

10.  Fiber-Based Electrochemical Biosensors for Monitoring pH and Transient Neurometabolic Lactate.

Authors:  Marsilea A Booth; Sally A N Gowers; Melinda Hersey; Isabelle C Samper; Seongjun Park; Polina Anikeeva; Parastoo Hashemi; Molly M Stevens; Martyn G Boutelle
Journal:  Anal Chem       Date:  2021-04-02       Impact factor: 6.986

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.