Firefighter Incident Rehabilitation: Interpreting Heart Rate Responses.

Denise L Smith, Jeannie M Haller, Ron Benedict, Lori Moore-Merrell.   

Abstract

UNLABELLED: The primary objective of this observational study was to document the heart rate (HR) responses of firefighters during incident rehabilitation following firefighting activity in a high-rise building with a simulated fire on the 10th floor. Additionally, the study investigated potential factors, including firefighting workload, ambient temperature, firefighter movement, and individual characteristics, that may have affected HR during recovery. Firefighters (n = 198) were assigned to perform a simulation of fire suppression, search and rescue, or material support during one of six firefighting trials that involved different crew sizes and ascent modes, and were performed in different environmental conditions. After completing the simulated firefighting activity, firefighters reported to a rehabilitation area on the 8th floor. The rehabilitation area was staffed by firefighter/paramedics. HR was monitored continuously during simulated firefighting activity and a 15-minute rehabilitation period. Average HR during rehabilitation (HRmean) was calculated and compared across trials. Simulated firefighting activity was performed in the summer in Virginia, USA, and ambient conditions varied among trials (mean ± SD: 31 ± 4°C; 46 ± 15% relative humidity; 32 ± 4°C heat index). Duration of simulated firefighting activity ranged from 12.0 to 20.3 minutes among trials (mean: 15.4 ± 5.2 minutes). Over all trials, mean peak HR during simulations was 173 ± 18 beats·min(-1). Mean HR over all trials at entry into rehabilitation was 149 ± 24 beats·min(-1). Following 15 minutes of recovery, mean HR over all trials was 126 ± 23 beats·min(-1). Exploratory analyses revealed that higher workload during firefighting (stair trials), higher ambient temperature (≥30°C), greater movement during rehabilitation (≥0.1 g-force), higher age (≥45 years), and higher BMI (≥30.0 kg·m(-2)) were associated with higher HR responses during rehabilitation. During complex emergency operations, emergency medical service personnel will likely encounter considerable variability in HR responses upon initial evaluation and throughout rehabilitation. Following one bout of firefighting activity during a simulated fire scenario, HR decreased but remained elevated well above resting values following 15 minutes of rehabilitation. Based on current fire service recommendations, the majority of firefighters (88%) would not have been released from rehabilitation and eligible for reassignment after a 15-minute rehabilitation period following a brief bout of simulated firefighting activity. KEY WORDS: medical monitoring, cardiac strain, firefighting.

Entities:  

Mesh:

Year:  2015        PMID: 25978308     DOI: 10.3109/10903127.2015.1037477

Source DB:  PubMed          Journal:  Prehosp Emerg Care        ISSN: 1090-3127            Impact factor:   3.077


  3 in total

1.  Functional Performance of Firefighters After Exposure to Environmental Conditions and Exercise.

Authors:  Kenneth E Games; Zachary K Winkelmann; Kaitlin D McGinnis; Jeremy S McAdam; David D Pascoe; JoEllen M Sefton
Journal:  J Athl Train       Date:  2019-12-26       Impact factor: 2.860

2.  Effects of cardiovascular health, musculoskeletal health and physical fitness on occupational performance of firefighters: protocol for a systematic review and meta-analysis.

Authors:  Jaron Ras; Andre Pascal Kengne; Denise Smith; Elpidoforos Soterakis Soteriades; Lloyd Leach
Journal:  BMJ Open       Date:  2022-07-21       Impact factor: 3.006

Review 3.  Effects of Cardiovascular Disease Risk Factors, Musculoskeletal Health, and Physical Fitness on Occupational Performance in Firefighters-A Systematic Review and Meta-Analysis.

Authors:  Jaron Ras; Andre P Kengne; Denise L Smith; Elpidoforos S Soteriades; Rucia V November; Lloyd Leach
Journal:  Int J Environ Res Public Health       Date:  2022-09-21       Impact factor: 4.614

  3 in total