An in vitro test model to study the performance and thrombogenicity of cardiovascular devices.

P Swier1, W J Bos, S F Mohammad, D B Olsen, W J Kolff.   

Abstract

During the development of cardiovascular devices, it is necessary to evaluate their performance in vitro under experimental conditions that closely resemble their use in vivo. Therefore, an in vitro test model was developed to evaluate the performance of cardiovascular devices with blood. The in vitro test model consists of a pneumatically driven 50 cc polyurethane ventricle with either mechanical or experimental polyurethane tricuspid semilunar valves, connected to a horseshoe-shaped blood reservoir. A sampling port permits frequent removal of blood for hematologic evaluation. All the couplings are of the quick connect type to facilitate assembly and exchange of parts. The total volume of blood in the test model is approximately 1.4 L, and experiments are conducted in the absence of an air-blood interface. Except for mechanical valves and the chosen test interface, the entire blood contacting surface consists of polyurethane. Fresh bovine heparinized blood is used for the experiments. After filling the reservoir and the ventricle with blood, the concentration of heparin is adjusted with protamine to an APTT level of three times normal (80-100 sec). Once this level of anticoagulation is achieved, the blood is circulated for the next 2-3 hr at the desired test parameters (beats/min, cardiac output, etc.). A number of hematologic parameters are monitored during the test, including APTT, PT, plasma free hemoglobin and ADP-induced platelet aggregation. With the help of this model a number of devices, including experimental polyurethane tricuspid semilunar valves, Silastic tube valves, valves with heparin coated leaflets, and small (50 cc) experimental ventricles have been studied.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1989        PMID: 2597563     DOI: 10.1097/00002480-198907000-00167

Source DB:  PubMed          Journal:  ASAIO Trans        ISSN: 0889-7190


  2 in total

1.  In vitro benchtop mock circulatory loop for heart failure with preserved ejection fraction emulation.

Authors:  Andrew Malone; Sean Gallagher; Jemil Saidi; Gina Rizq; Enda O'Dowd; Derek Vallence; Aamir Hameed
Journal:  Front Cardiovasc Med       Date:  2022-07-22

Review 2.  New Insights in the Diagnosis and Treatment of Heart Failure.

Authors:  Giulio Agnetti; Massimo F Piepoli; Giuseppe Siniscalchi; Francesco Nicolini
Journal:  Biomed Res Int       Date:  2015-10-26       Impact factor: 3.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.