Literature DB >> 2597530

Evaluation of right ventricular function during clinical left ventricular assistance.

R L Kormos1, T Gasior, J Antaki, J M Armitage, Y Miyamoto, H S Borovetz, R L Hardesty, B P Griffith.   

Abstract

Hemodynamic and mechanical parameters of right ventricular (RV) performance were measured in eight patients undergoing left ventricular (LV) assistance as a bridge to cardiac transplantation. All patients, even those with impaired RV performance, survived support and transplantation. The reduction of LV afterload produced by the left ventricular assist system (LVAS) results in RV afterload reduction, which permits even the marginal RV to function adequately during LVAS support.

Entities:  

Mesh:

Year:  1989        PMID: 2597530     DOI: 10.1097/00002480-198907000-00121

Source DB:  PubMed          Journal:  ASAIO Trans        ISSN: 0889-7190


  1 in total

1.  Evolving experience with mechanical circulatory support.

Authors:  R L Kormos; H S Borovetz; J M Armitage; R L Hardesty; G C Marrone; B P Griffith
Journal:  Ann Surg       Date:  1991-10       Impact factor: 12.969