Literature DB >> 2597516

Comparative in vitro encrustation studies of biomaterials in human urine.

M J Gleeson1, J A Glueck, L Feldman, D P Griffith, G P Noon.   

Abstract

A new dynamic in vitro human urine model was developed to compare biomaterial encrustation. The model incorporates a capacity to study seven biomaterials, a daily urine inflow of 500 ml, a reservoir capacity of 700 ml, and a turnover rate of four days. Encrustation studies performed for 2 weeks in sterile and infected (Proteus Vulgaris) urine on segmented polyether polyurethane, polyester polyurethane, silicone (Mitsui), silicone (Dow Corning), biothane, biolor 1 and biolor 11 demonstrated that biolor 11 (silicone-carbon composite) caused the least encrustation. Encrustation analysis showed brushite in the sterile model and struvite and ammonium acid urate in the infected mode I. Biolor II should have beneficial applications in catheters, stents and prosthetics which come in contact with urine.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2597516     DOI: 10.1097/00002480-198907000-00104

Source DB:  PubMed          Journal:  ASAIO Trans        ISSN: 0889-7190


  5 in total

1.  Surface-Treated Pellethanes: Comparative Quantification of Encrustation in Artificial Urine Solution.

Authors:  Courtney M Cottone; Sherry Lu; Yi Xi Wu; Kevin Guan; Renai Yoon; Luke Limfueco; Tuyen Hoang; Winston Ciridon; Buddy D Ratner; Kathleen R Johnson; Roshan M Patel; Jaime Landman; Ralph V Clayman
Journal:  J Endourol       Date:  2020-06-16       Impact factor: 2.942

2.  Imaging and Chemical Analysis of External and Internal Ureteral Stent Encrustation.

Authors:  Tal Amitay-Rosen; Ishai Dror; Yaniv Shilo; Brian Berkowitz
Journal:  Res Rep Urol       Date:  2022-04-23

Review 3.  Urinary Stent Development and Evaluation Models: In Vitro, Ex Vivo and In Vivo-A European Network of Multidisciplinary Research to Improve Urinary Stents (ENIUS) Initiative.

Authors:  Noor Buchholz; Alberto Budia; Julia de la Cruz; Wolfgang Kram; Owen Humphreys; Meital Reches; Raquel Valero Boix; Federico Soria
Journal:  Polymers (Basel)       Date:  2022-04-19       Impact factor: 4.967

4.  Urethral beading: A unique radiographic finding following laser lithotripsy for ureteric stent encrustation.

Authors:  Amber Fern Irene Matkowski
Journal:  Radiol Case Rep       Date:  2021-12-28

5.  Does potassium citrate administration change the type and composition of encrusted material on Double-J stent compared to primary stone?

Authors:  Abdolreza Mohammadi; Mohammad Mehdi Rakebi; Maryam Gholamnezhad; Mahin Ahmadi Pishkuhi; Seyed Mohammad Kazem Aghamir
Journal:  Int Urol Nephrol       Date:  2021-05-29       Impact factor: 2.370

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.