Literature DB >> 25974956

Admission Control Over Internet of Vehicles Attached With Medical Sensors for Ubiquitous Healthcare Applications.

Di Lin, Fabrice Labeau, Yuanzhe Yao, Athanasios V Vasilakos, Yu Tang.   

Abstract

Wireless technologies and vehicle-mounted or wearable medical sensors are pervasive to support ubiquitous healthcare applications. However, a critical issue of using wireless communications under a healthcare scenario rests at the electromagnetic interference (EMI) caused by radio frequency transmission. A high level of EMI may lead to a critical malfunction of medical sensors, and in such a scenario, a few users who are not transmitting emergency data could be required to reduce their transmit power or even temporarily disconnect from the network in order to guarantee the normal operation of medical sensors as well as the transmission of emergency data. In this paper, we propose a joint power and admission control algorithm to schedule the users' transmission of medical data. The objective of this algorithm is to minimize the number of users who are forced to disconnect from the network while keeping the EMI on medical sensors at an acceptable level. We show that a fixed point of proposed algorithm always exists, and at the fixed point, our proposed algorithm can minimize the number of low-priority users who are required to disconnect from the network. Numerical results illustrate that the proposed algorithm can achieve robust performance against the variations of mobile hospital environments.

Mesh:

Year:  2015        PMID: 25974956     DOI: 10.1109/JBHI.2015.2431744

Source DB:  PubMed          Journal:  IEEE J Biomed Health Inform        ISSN: 2168-2194            Impact factor:   5.772


  4 in total

Review 1.  Real-Time Remote-Health Monitoring Systems: a Review on Patients Prioritisation for Multiple-Chronic Diseases, Taxonomy Analysis, Concerns and Solution Procedure.

Authors:  K I Mohammed; A A Zaidan; B B Zaidan; O S Albahri; M A Alsalem; A S Albahri; Ali Hadi; M Hashim
Journal:  J Med Syst       Date:  2019-06-11       Impact factor: 4.460

Review 2.  Systematic Review of Real-time Remote Health Monitoring System in Triage and Priority-Based Sensor Technology: Taxonomy, Open Challenges, Motivation and Recommendations.

Authors:  O S Albahri; A S Albahri; K I Mohammed; A A Zaidan; B B Zaidan; M Hashim; Omar H Salman
Journal:  J Med Syst       Date:  2018-03-22       Impact factor: 4.460

Review 3.  Real-Time Remote Health-Monitoring Systems in a Medical Centre: A Review of the Provision of Healthcare Services-Based Body Sensor Information, Open Challenges and Methodological Aspects.

Authors:  O S Albahri; A A Zaidan; B B Zaidan; M Hashim; A S Albahri; M A Alsalem
Journal:  J Med Syst       Date:  2018-07-25       Impact factor: 4.460

Review 4.  Real-Time Fault-Tolerant mHealth System: Comprehensive Review of Healthcare Services, Opens Issues, Challenges and Methodological Aspects.

Authors:  A S Albahri; A A Zaidan; O S Albahri; B B Zaidan; M A Alsalem
Journal:  J Med Syst       Date:  2018-06-23       Impact factor: 4.460