Literature DB >> 25973661

A user's guide to intra-abdominal pressure measurement.

Michael Sugrue, Jan J De Waele, Bart L De Keulenaer, Derek J Roberts, Manu L N G Malbrain1.   

Abstract

The intra-abdominal pressure (IAP) measurement is a key to diagnosing and managing critically ill medical and surgical patients. There are an increasing number of techniques that allow us to measure the IAP at the bedside. This paper reviews these techniques. IAP should be measured at end-expiration, with the patient in the supine position and ensuring that there is no abdominal muscle activity. The intravesicular IAP measurement is convenient and considered the gold standard. The level where the mid-axillary line crosses the iliac crest is the recommended zero reference for the transvesicular IAP measurement; moreover, marking this level on the patient increases reproducibility. Protocols for IAP measurement should be developed for each ICU based on the locally available tools and equipment. IAP measurement techniques are safe, reproducible and accurate and do not increase the risk of urinary tract infection. Continuous IAP measurement may offer benefits in specific situations in the future. In conclusion, the IAP measurement is a reliable and essential adjunct to the management of patients at risk of intra-abdominal hypertension.

Entities:  

Mesh:

Year:  2015        PMID: 25973661     DOI: 10.5603/AIT.a2015.0025

Source DB:  PubMed          Journal:  Anaesthesiol Intensive Ther        ISSN: 1642-5758


  10 in total

1.  Incidence, Outcomes, and Factors Associated with Intra-Abdominal Hypertension and Primary Abdominal Compartment Syndrome in Abdominopelvic Injury Patients.

Authors:  Amonpon Kanlerd; Krissada Nakornchai; Karikarn Auksornchart; Warapan Watkwaw
Journal:  Anesthesiol Res Pract       Date:  2020-08-17

2.  Bench Validation of a Handcrafted Prototype Catheter for Intra-gastric Pressure Monitoring.

Authors:  Alberto Federico García; Julián Chica Yantén; Álvaro Ignacio Sánchez; Jose Luis Aldana; Jorge Humberto Mejía; Daniela Burbano; Camilo Salazar
Journal:  World J Surg       Date:  2020-06       Impact factor: 3.352

3.  Intra-abdominal pressure may be elevated in patients with open abdomen after emergent laparotomy.

Authors:  Ohad Guetta; Evgeni Brotfain; Gad Shaked; Gilbert Sebbag; Moti Klein; David Czeiger
Journal:  Langenbecks Arch Surg       Date:  2020-01-18       Impact factor: 3.445

Review 4.  The significance of intra-abdominal pressure in neurosurgery and neurological diseases: a narrative review and a conceptual proposal.

Authors:  Paul R A M Depauw; Rob J M Groen; Johannes Van Loon; Wilco C Peul; Manu L N G Malbrain; Jan J De Waele
Journal:  Acta Neurochir (Wien)       Date:  2019-03-25       Impact factor: 2.216

Review 5.  Abdominal compartment syndrome due to extremely elongated sigmoid colon and rectum plus fecal impaction caused by disuse syndrome and diabetic neuropathy: a case report and review of the literature.

Authors:  Daisuke Usuda; Kohei Takanaga; Ryusho Sangen; Toshihiro Higashikawa; Shinichi Kinami; Hitoshi Saito; Yuji Kasamaki
Journal:  J Med Case Rep       Date:  2020-11-13

6.  Ultrasonography in the diagnosis and monitoring of intra-abdominal hypertension and abdominal compartment syndrome: Ultrasonografia a nadciśnienie wewnątrzbrzuszne i zespół przedziału brzusznego.

Authors:  Andrzej Smereczyński; Katarzyna Kołaczyk; Elżbieta Bernatowicz
Journal:  J Ultrason       Date:  2020-09-28

7.  Novel technique for continuous pressure monitoring of esophageal balloon in balloon tamponade device for acute variceal bleed.

Authors:  Brian H Torres-Gonzalez; Thomas L Powell; Jennifer Yee; Katherine M Hunold
Journal:  J Am Coll Emerg Physicians Open       Date:  2022-04-29

8.  Continuous Monitoring of Intra-abdominal Pressure in Severe Acute Pancreatitis Leads to Early Detection of Abdominal Compartment Syndrome: A Case Report.

Authors:  Olutola Akiode; Vanessa Moll; Gregory Schears
Journal:  Cureus       Date:  2022-04-29

9.  Continuous intra-abdominal pressure: is it ready for prime time?

Authors:  Manu L N G Malbrain; Bart L De Keulenaer; Ashish K Khanna
Journal:  Intensive Care Med       Date:  2022-08-04       Impact factor: 41.787

10.  Stretchable Capacitive Pressure Sensing Sleeve Deployable onto Catheter Balloons towards Continuous Intra-Abdominal Pressure Monitoring.

Authors:  Kirthika Senthil Kumar; Zongyuan Xu; Manivannan Sivaperuman Kalairaj; Godwin Ponraj; Hui Huang; Chi-Fai Ng; Qing Hui Wu; Hongliang Ren
Journal:  Biosensors (Basel)       Date:  2021-05-14
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.