Literature DB >> 25970692

Glycoform Separation and Characterization of Cetuximab Variants by Middle-up Off-Line Capillary Zone Electrophoresis-UV/Electrospray Ionization-MS.

Michael Biacchi1, Rabah Gahoual1, Nassur Said1, Alain Beck2, Emmanuelle Leize-Wagner1, Yannis-Nicolas François1.   

Abstract

Monoclonal antibodies (mAbs) are highly complex glycoproteins that present a wide range of microheterogeneities that requires multiple analytical methods for full structure assessment and quality control. Capillary zone electrophoresis-mass spectrometry (CZE-MS) couplings, especially by electrospray ionization (ESI), appear to be really attractive methods for the characterization of biological samples. However, due to the presence of non- or medium volatile salts in the background electrolyte (BGE), online CZE-ESI-MS coupling is difficult to implement for mAbs isoforms separation. Here, we report an original strategy to perform off-line CZE-ESI-MS using CZE-UV/fraction collection technology to perform CZE separation, followed by ESI-MS infusion of the different fractions using the capillary electrophoresis-electrospray ionization (CESI) interface as the nanoESI infusion platform. As the aim is to conserve electrophoretic resolution and complete compatibility with ESI-MS without sample treatment, hydroxypropylcellulose (HPC) coated capillary was used to prevent analyte adsorption and asymmetric CZE conditions involving different BGE at both ends of the capillary have been developed. The efficiency of our strategy was validated with the separation of Cetuximab charge variant by the middle-up approach. Molecular weights were measured for six charge variants detected in the CZE separation of Cetuximab subunits. The first three peaks correspond to Fc/2 variants with electrophoretic resolution up to 2.10, and the last three peaks correspond to F(ab')2 variants with average electrophoretic resolution of 1.05. Two Fc/2 C-terminal lysine variants were identified and separated. Moreover, separation of Fc/2 fragments allowed the glycoprofiling of the variants with the characterization of 7 different glycoforms. Regarding the F(ab')2 domain, 8 glycoforms were detected and separated in three different peaks following the presence of N-glycolyl neuraminic acid residues in some glycan structures. This work highlights the potential of CZE technology to perform separation of mAbs especially when they carry sialic acid carbohydrates.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25970692     DOI: 10.1021/acs.analchem.5b00928

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  9 in total

1.  Site-selective chemoenzymatic glycoengineering of Fab and Fc glycans of a therapeutic antibody.

Authors:  John P Giddens; Joseph V Lomino; David J DiLillo; Jeffrey V Ravetch; Lai-Xi Wang
Journal:  Proc Natl Acad Sci U S A       Date:  2018-11-05       Impact factor: 11.205

2.  Comparison of originator and biosimilar therapeutic monoclonal antibodies using comprehensive two-dimensional liquid chromatography coupled with time-of-flight mass spectrometry.

Authors:  Matthew Sorensen; David C Harmes; Dwight R Stoll; Gregory O Staples; Szabolcs Fekete; Davy Guillarme; Alain Beck
Journal:  MAbs       Date:  2016-06-30       Impact factor: 5.857

Review 3.  Middle-down approach: a choice to sequence and characterize proteins/proteomes by mass spectrometry.

Authors:  P Boomathi Pandeswari; Varatharajan Sabareesh
Journal:  RSC Adv       Date:  2019-01-02       Impact factor: 4.036

4.  Subunit mass analysis for monitoring antibody oxidation.

Authors:  Izabela Sokolowska; Jingjie Mo; Jia Dong; Michael J Lewis; Ping Hu
Journal:  MAbs       Date:  2017-01-20       Impact factor: 5.857

Review 5.  Capillary Electrophoresis Separations of Glycans.

Authors:  Grace Lu; Cassandra L Crihfield; Srikanth Gattu; Lindsay M Veltri; Lisa A Holland
Journal:  Chem Rev       Date:  2018-03-12       Impact factor: 60.622

6.  Proteoform-Resolved FcɤRIIIa Binding Assay for Fab Glycosylated Monoclonal Antibodies Achieved by Affinity Chromatography Mass Spectrometry of Fc Moieties.

Authors:  Steffen Lippold; Simone Nicolardi; Manfred Wuhrer; David Falck
Journal:  Front Chem       Date:  2019-10-24       Impact factor: 5.221

Review 7.  Analytical Similarity Assessment of Biosimilars: Global Regulatory Landscape, Recent Studies and Major Advancements in Orthogonal Platforms.

Authors:  Neh Nupur; Srishti Joshi; Davy Gulliarme; Anurag S Rathore
Journal:  Front Bioeng Biotechnol       Date:  2022-02-09

8.  [Analysis of glycan ratio of Chinese hamster ovary cell-cetuximab antigen-binding segment via rapid enzyme digestion with endo-β-N-acetylglucosaminidase F].

Authors:  Qian Cheng; Daihui Jia; Bohui Zhang; Junyan Xu; Zhe Shao; Yingfeng Huang; Xun Zou
Journal:  Se Pu       Date:  2022-02-08

9.  Monitoring antigenic protein integrity during glycoconjugate vaccine synthesis using capillary electrophoresis-mass spectrometry.

Authors:  Sara Tengattini; Elena Domínguez-Vega; Caterina Temporini; Marco Terreni; Govert W Somsen
Journal:  Anal Bioanal Chem       Date:  2016-07-02       Impact factor: 4.142

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.