Literature DB >> 25968739

Double-clad fiber coupler for partially coherent detection.

Etienne De Montigny, Wendy-Julie Madore, Olivier Ouellette, Gabriel Bernard, Mikael Leduc, Mathias Strupler, Caroline Boudoux, Nicolas Godbout.   

Abstract

Double-clad fibers (DCF) have many advantages in fibered confocal microscopes as they allow for coherent illumination through their core and partially coherent detection through their inner cladding. We report a double-clad fiber coupler (DCFC) made from small inner cladding DCF that preserves optical sectioning in confocal microscopy while increasing collection efficiency and reducing coherent effects. Due to the small inner cladding, previously demonstrated fabrication methods could not be translated to this coupler's fabrication. To make such a coupler possible, we introduce in this article three new design concepts. The resulting DCFC fabricated using two custom fibers and a modified fusion-tapering technique achieves high multimodal extraction (≥70 %) and high single mode transmission (≥80 %). Its application to reflectance confocal microscopy showed a 30-fold increase in detected signal intensity, a 4-fold speckle contrast reduction with a penalty in axial resolution of a factor 2. This coupler paves the way towards more efficient confocal microscopes for clinical applications.

Entities:  

Year:  2015        PMID: 25968739     DOI: 10.1364/OE.23.009040

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  7 in total

1.  Laser tissue coagulation and concurrent optical coherence tomography through a double-clad fiber coupler.

Authors:  Kathy Beaudette; Hyoung Won Baac; Wendy-Julie Madore; Martin Villiger; Nicolas Godbout; Brett E Bouma; Caroline Boudoux
Journal:  Biomed Opt Express       Date:  2015-03-16       Impact factor: 3.732

2.  Simultaneous multimodal ophthalmic imaging using swept-source spectrally encoded scanning laser ophthalmoscopy and optical coherence tomography.

Authors:  Joseph D Malone; Mohamed T El-Haddad; Ivan Bozic; Logan A Tye; Lucas Majeau; Nicolas Godbout; Andrew M Rollins; Caroline Boudoux; Karen M Joos; Shriji N Patel; Yuankai K Tao
Journal:  Biomed Opt Express       Date:  2016-12-12       Impact factor: 3.732

3.  Spectrally encoded coherence tomography and reflectometry: Simultaneous en face and cross-sectional imaging at 2 gigapixels per second.

Authors:  Mohamed T El-Haddad; Ivan Bozic; Yuankai K Tao
Journal:  J Biophotonics       Date:  2017-12-27       Impact factor: 3.207

4.  Tri-modal microscope for head and neck tissue identification.

Authors:  Etienne De Montigny; Nadir Goulamhoussen; Wendy-Julie Madore; Mathias Strupler; Olguta Ecaterina Gologan; Tareck Ayad; Caroline Boudoux
Journal:  Biomed Opt Express       Date:  2016-02-02       Impact factor: 3.732

5.  Handheld tunable focus confocal microscope utilizing a double-clad fiber coupler for in vivo imaging of oral epithelium.

Authors:  Cory Olsovsky; Taylor Hinsdale; Rodrigo Cuenca; Yi-Shing Lisa Cheng; John M Wright; Terry D Rees; Javier A Jo; Kristen C Maitland
Journal:  J Biomed Opt       Date:  2017-05-01       Impact factor: 3.170

6.  In vivo subdiffuse scanning laser oximetry of the human retina.

Authors:  Mathi Damodaran; Arjen Amelink; Fabio Feroldi; Benjamin Lochocki; Valentina Davidoiu; Johannes F de Boer
Journal:  J Biomed Opt       Date:  2019-09       Impact factor: 3.170

Review 7.  Double-Clad Fiber-Based Multifunctional Biosensors and Multimodal Bioimaging Systems: Technology and Applications.

Authors:  Kathy Beaudette; Jiawen Li; Joseph Lamarre; Lucas Majeau; Caroline Boudoux
Journal:  Biosensors (Basel)       Date:  2022-02-01
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.