Literature DB >> 25966464

A polyaniline based ultrasensitive potentiometric immunosensor for cardiac troponin complex detection.

Qi Zhang1, Alok Prabhu2, Avdar San2, Jafar F Al-Sharab3, Kalle Levon2.   

Abstract

An ultrasensitive immunosensor based on potentiometric ELISA for the detection of a cardiac biomarker, troponin I-T-C (Tn I-T-C) complex, was developed. The sensor fabrication involves typical sandwich ELISA procedures, while the final signal readout was achieved using open circuit potentiometry (OCP). Glassy carbon (GC) working electrodes were first coated with emulsion-polymerized polyaniline/dinonylnaphthalenesulfonic acid (PANI/DNNSA) and the coated surface was utilized as a transducer layer on which sandwich ELISA incubation steps were performed. An enzymatic reaction between o-phenylenediamine (OPD) and hydrogen peroxide (H2O2) was catalyzed by horseradish peroxidase (HRP) labeled on the secondary antibodies. The polymer transducer charged state was mediated through electron (e(-)) and charge transfers between the transducer and charged species generated by the same enzymatic reaction. Such a change in the polymer transducer led to potential variations against an Ag/AgCl reference electrode as a function of Tn I-T-C complex concentration during incubations. The sequence of OPD and H2O2 additions, electrochemical properties of the PANI/DNNSA layer and non-specific binding prevention were all crucial factors for the assay performance. Under optimized conditions, the assay has a low limit of detection (LOD) (< 5 pg/mL or 56 fM), a wide dynamic range (> 6 orders of magnitude), high repeatability (coefficient of variance < 8% for all concentrations higher than 5 pg/mL) and a short detection time (< 10 min).
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  ELISA; Polyaniline; Potentiometry; Troponin I–T–C; Ultrasensitive immunosensor

Mesh:

Substances:

Year:  2015        PMID: 25966464     DOI: 10.1016/j.bios.2015.04.084

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  5 in total

Review 1.  Dynamic Immune/Inflammation Precision Medicine: The Good and the Bad Inflammation in Infection and Cancer.

Authors:  Jean-François Rossi; Zhao Yang Lu; Cesare Massart; Kalle Levon
Journal:  Front Immunol       Date:  2021-02-23       Impact factor: 7.561

2.  Synthesis and application of aminophenyl-s-triazine derivatives as potential flame retardants in the modification of epoxy resins.

Authors:  Haiyang Wu; Rong Hu; Birong Zeng; Li Yang; Ting Chen; Wei Zheng; Xinyu Liu; Weiang Luo; Lizong Dai
Journal:  RSC Adv       Date:  2018-11-08       Impact factor: 3.361

3.  Rapid fluorescence immunoassay of benzo[a]pyrene in mainstream cigarette smoke based on a dual-functional antibody-DNA conjugate.

Authors:  Ziyan Fan; Zhonghao Li; Shanshan Liu; Fei Yang; Zhaoyang Bian; Ying Wang; Gangling Tang; Qinxiao Zhao; Huimin Deng; Shili Liu
Journal:  RSC Adv       Date:  2018-08-21       Impact factor: 3.361

4.  Microfabricated passive resonator biochip for sensitive radiofrequency detection and characterization of glucose.

Authors:  Gyan Raj Koirala; Eun-Seong Kim; Rajendra Dhakal; Zorigt Chuluunbaatar; Yong Hwa Jo; Sung-Soo Kim; Nam-Young Kim
Journal:  RSC Adv       Date:  2018-09-24       Impact factor: 4.036

5.  EMI shielding of ABS composites filled with different temperature-treated equal-quantity charcoals.

Authors:  Krishna Kamal Halder; V K Sachdev; Monika Tomar; Vinay Gupta
Journal:  RSC Adv       Date:  2019-07-30       Impact factor: 3.361

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.