Literature DB >> 25966463

Fluorescent detection of Hg2+ and Pb2+ using GeneFinder™ and an integrated functional nucleic acid.

Shenshan Zhan1, Hanchu Xu1, Dongwei Zhang2, Bing Xia2, Xuejia Zhan1, Lumei Wang1, Jing Lv1, Pei Zhou3.   

Abstract

This paper reports a simple fluorescent assay for the determination of Hg(2+) and Pb(2+) by using a DNA intercalator GeneFinder™ (GF) and an integrated functional nucleic acid (FNA). In the absence of Hg(2+) and Pb(2+), GF intercalated with the FNA and released moderate strong fluorescence. While in the presence of Hg(2+) or Pb(2+), the FNA would be induced to form T-Hg(2+)-T or G-quadruplex structure, interacted with which the GF would exhibit extremely strong or very weak fluorescence. By monitoring the fluorescence changes upon addition of these two ions, the Hg(2+) and Pb(2+) could be selectively detected as low as 3.23 ppb and 2.62 ppb. As the main advantage of this assay is simplicity and the feasibility was demonstrated by detecting Hg(2+) and Pb(2+) in spiked water samples, this assay holds great potential for the development of a cost effective and useful tool for environmental monitoring.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Fluorescent assay; Functional nucleic acid; G-quadruplex; Hg(2+) detection; Pb(2+) detection; T–Hg(2+)–T

Mesh:

Substances:

Year:  2015        PMID: 25966463     DOI: 10.1016/j.bios.2015.04.021

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

1.  An electrochemical aptasensor based on gold@polypyrrole composites for detection of lead ions.

Authors:  Jina Ding; Yang Liu; Dongwei Zhang; Minglei Yu; Xuejia Zhan; Dan Zhang; Pei Zhou
Journal:  Mikrochim Acta       Date:  2018-11-13       Impact factor: 5.833

Review 2.  Organic Material Based Fluorescent Sensor for Hg2+: a Brief Review on Recent Development.

Authors:  Muhammad Saleem; Muhammad Rafiq; Muhammad Hanif
Journal:  J Fluoresc       Date:  2016-09-19       Impact factor: 2.217

3.  An Electrochemical Aptasensor for Pb2+ Detection Based on Metal-Organic-Framework-Derived Hybrid Carbon.

Authors:  Jina Ding; Dongwei Zhang; Yang Liu; Xuejia Zhan; Yitong Lu; Pei Zhou; Dan Zhang
Journal:  Biosensors (Basel)       Date:  2020-12-22

Review 4.  Practical Application of Aptamer-Based Biosensors in Detection of Low Molecular Weight Pollutants in Water Sources.

Authors:  Wei Zhang; Qing Xiu Liu; Zhi Hou Guo; Jun Sheng Lin
Journal:  Molecules       Date:  2018-02-07       Impact factor: 4.411

  4 in total