Literature DB >> 25966419

A peroxidase biomimetic system based on Fe3O4 nanoparticles in non-enzymatic sensors.

Juan A Ramos Guivar1, Edson G R Fernandes2, Valtencir Zucolotto2.   

Abstract

Magnetic nanoparticles have been applied in many areas of nanomedicine. Sensing platforms based on this type of nanoparticles have received attention due to the relative low cost and biocompatibility. Biosensor is the most widely investigated type of analytical device. This type of sensor combines the physicochemical transduction with the incorporation of biological sensing components. Among the biological components, enzymes are the most commonly used as sensitive elements. However, natural enzymes may exhibit serious disadvantages such as lack of stability and loss of catalytic activity after immobilization. The study of enzymatic biomimetic systems are of great interest. This study reports the development of a new sensor composed of Fe3O4@CTAB and poly(sodium 4-styrenesulfonate) (PSS) films assembled via Layer-by-Layer (LbL) technique and used as peroxidase mimetic systems. Magnetic nanoparticles (MNps) were synthesized using thermal decomposition method and further dispersed to aqueous medium by ligand modification reaction using cetyltrimethylammonium bromide (CTAB). The amperometric detection limit of H2O2 was found to be ca. 103 µmol L(-1). By chronoamperometry, the peroxidase biomimetic sensor exhibited a linear response for H2O2 in the range from 100 µmol L(-1) to 1.8 mmol L(-1) (R(2) = 0.994) with sensitivity of 16 nA mol(-1) L. The apparent Michaelis-Menten constant was 5.3 mmol L(-1), comparable with some biosensors based on peroxidase enzyme. Moreover, the sensor presented a reproducibility of ca. 7.7% (n = 4) and their response (response time: 90 s) is not significantly affected in the presence of some interferents including K(+), Na(+), Cl(-), Mg(2+), Ca(2+), and Uric Acid.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Biomimetic sensor; Hydrogen peroxide; Layer-by-Layer films; Magnetic nanoparticles

Mesh:

Substances:

Year:  2015        PMID: 25966419     DOI: 10.1016/j.talanta.2015.03.017

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  Treatment of simulated electroplating wastewater containing Ni(II)-EDTA by Fenton oxidation combined with recycled ferrite process under ambient temperature.

Authors:  Lei Wang; Zhijun Luo; Jing Wei; Xiangtong Zhou; Xiaoying Zhang; Huicheng Ni; Jing Wang; Youye Song; Zhiren Wu
Journal:  Environ Sci Pollut Res Int       Date:  2019-08-12       Impact factor: 4.223

2.  Synthesizing Electrodes Into Electrochemical Sensor Systems.

Authors:  Yulia G Mourzina; Yuri E Ermolenko; Andreas Offenhäusser
Journal:  Front Chem       Date:  2021-03-31       Impact factor: 5.221

Review 3.  Iron Oxide Nanozyme: A Multifunctional Enzyme Mimetic for Biomedical Applications.

Authors:  Lizeng Gao; Kelong Fan; Xiyun Yan
Journal:  Theranostics       Date:  2017-07-22       Impact factor: 11.556

Review 4.  Sensors Based on Bio and Biomimetic Receptors in Medical Diagnostic, Environment, and Food Analysis.

Authors:  Alisa N Kozitsina; Tatiana S Svalova; Natalia N Malysheva; Andrei V Okhokhonin; Marina B Vidrevich; Khiena Z Brainina
Journal:  Biosensors (Basel)       Date:  2018-04-01
  4 in total