Literature DB >> 25966415

Detection of 17β-estradiol in water samples by a novel double-layer molecularly imprinted film-based biosensor.

Yuan Tan1, Tianxin Wei2.   

Abstract

This study reports a novel double-layer molecularly imprinted film (MIF)-based biosensor for rapid, sensitive and highly selective detection of small molecule 17β-estradiol (E2) that is frequently detected in environmental water samples. In this system, the modification of gold surface of SPR chip was performed by 1-dodecanethiol. Then double-layer MIF was generated on the 1-dodecanethiol modified gold surface. The non-modified and imprinted surfaces were characterized by atomic force microscopy (AFM), scanning electron microscope (SEM) and contact angle measurements. Analysis of surface plasmon resonance (SPR) spectroscopy showed that the imprinted sensing film displayed good selectivity for E2 compared to other analog molecules and NIF. A good linear relationship was obtained between the SPR angle and E2 concentrations over a range of 2.50×10(-13)-2.50×10(-)(9)mol/L (R(2)=0.993) with the lowest measurable concentration of 2.50×10(-13)mol/L. The sensor can be regenerated with the mixture of acetic acid and PBS buffer (v/v=1:9) as a desorption agent over tens of times without significant deterioration of the sensor performance. Potential interference of real environmental sample matrix was assessed by spiked samples in several waste seawater effluents. This portable sensor system can be successfully applied for on-site real-time inexpensive and easy-to-use monitoring of E2 or other small molecule pollutants in environmental samples such as effluents or water bodies.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  17β-Estradiol; Double-layer MIF; Surface plasmon resonance (SPR)

Mesh:

Substances:

Year:  2015        PMID: 25966415     DOI: 10.1016/j.talanta.2015.04.019

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  β-Estradiol and ethinyl-estradiol contamination in the rivers of the Carpathian Basin.

Authors:  Péter Avar; Zita Zrínyi; Gábor Maász; Anikó Takátsy; Sándor Lovas; László G-Tóth; Zsolt Pirger
Journal:  Environ Sci Pollut Res Int       Date:  2016-03-02       Impact factor: 4.223

Review 2.  Recent advances in the potential applications of luminescence-based, SPR-based, and carbon-based biosensors.

Authors:  Uttpal Anand; Arvind K Singh Chandel; Patrik Oleksak; Amarnath Mishra; Ondrej Krejcar; Ishan H Raval; Abhijit Dey; Kamil Kuca
Journal:  Appl Microbiol Biotechnol       Date:  2022-04-06       Impact factor: 5.560

Review 3.  Practical Application of Aptamer-Based Biosensors in Detection of Low Molecular Weight Pollutants in Water Sources.

Authors:  Wei Zhang; Qing Xiu Liu; Zhi Hou Guo; Jun Sheng Lin
Journal:  Molecules       Date:  2018-02-07       Impact factor: 4.411

  3 in total