Multi-line transmission combined with minimum variance beamforming in medical ultrasound imaging.

Adi Rabinovich, Arie Feuer, Zvi Friedman.   

Abstract

Increasing medical ultrasound imaging frame rate is important in several applications such as cardiac diagnostic imaging, where it is desirable to be able to examine the temporal behavior of fast phases in the cardiac cycle. This is particularly true in 3-D imaging, where current frame rate is still much slower than standard 2-D, B-mode imaging. Recently, a method that increases frame rate, labeled multi-line transmission (MLT), was reintroduced and analyzed. In MLT scanning, the transmission is simultaneously focused at several directions. This scan mode introduces artifacts that stem from the overlaps of the receive main lobe with the transmit side lobes of additional transmit directions besides the one of interest. Similar overlaps occur between the transmit main lobe with receive side lobes. These artifacts are known in the signal processing community as cross-talk. Previous studies have concentrated on proper transmit and receive apodization, as well as transmit directions arrangement in the transmit event, to reduce the cross-talk artifacts. This study examines the possibility of using adaptive beamforming, specifically, minimum variance (MV) and linearly constrained minimum variance (LCMV) beamforming, to reduce the cross-talk artifacts, and maintain or even improve image quality characteristics. Simulation results, as well as experimental phantom and in vivo cardiac data, demonstrate the feasibility of reducing cross-talk artifacts with MV beamforming. The MV and LCMV results achieve superior spatial resolution, not only over other MLT methods with data-independent apodization, but even over that of single-line transmission (SLT) without receive apodization. The MV beamformer is shown to be less sensitive to wider transmit profiles required to reduce the transmit crosstalk artifacts. MV beamforming, combined with the wider transmit profiles, can provide a good approach for MLT scanning with reduced cross-talk artifacts, without compromising spatial resolution, and even improving it. We also demonstrate that the MV and LCMV beamformers lead to almost identical results. This is because of their very similar beampatterns, except for the sharp nullifying properties that the LCMV beamformer has around interfering beams.

Entities:  

Mesh:

Year:  2015        PMID: 25965676     DOI: 10.1109/TUFFC.2014.006754

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  1 in total

1.  Image improvement in linear-array photoacoustic imaging using high resolution coherence factor weighting technique.

Authors:  Moein Mozaffarzadeh; Bahador Makkiabadi; Maryam Basij; Mohammad Mehrmohammadi
Journal:  BMC Biomed Eng       Date:  2019-04-05
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.