Literature DB >> 25965636

Clinical evaluation of zirconia-based restorations on implants: a retrospective cohort study from the AIOP clinical research group.

Carlo Monaco, Mauro Caldari, Roberto Scotti.   

Abstract

PURPOSE: The aim of this retrospective cohort study was to evaluate the clinical performance of zirconia-based implant-supported single crowns and fixed dental prostheses (FDPs) made by 15 members of the Italian Academy of Prosthetic Dentistry (AIOP) over a time period of up to 5 years.
MATERIALS AND METHODS: One hundred thirty-one patients were treated with a total of 210 zirconia-based single crowns and FDPs on implants in anterior and posterior regions. A cohort group with parafunctional habits was compared with patients without parafunctional habits according to the esthetic, functional, and biologic United States Public Health Service criteria modified by the FDI World Dental Federation.
RESULTS: The estimated cumulative survival (ECS) and standard error (SE) of all restorations on implants was 91.95% ± 1.39%, and the estimated cumulative success (ECSs) and SE was 88.37% ± 1.72%. The ECS of single crowns and FDPs was 91.25% ± 3.69% and 95.23% ± 2.28%, respectively, and the estimated cumulative success rates were 88.84% ± 2.05% and 87.96% ± 3.16%, respectively. Mechanical failures, including four zirconia core fractures, three hairline cracks, four chippings, and five delaminations of the ceramic veneering material, were recorded during a 1- to 5-year observation period. The odds ratio of 3.39 (95% confidence interval: 1.18 to 9.73) showed a moderate association between parafunction and failure.
CONCLUSIONS: Zirconiabased implant-supported restorations showed encouraging clinical results over a period of up to 5 years, but more clinical data are needed before these restorations can be considered a viable treatment alternative. Mechanical failures were primarily observed in patients with parafunctions.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25965636     DOI: 10.11607/ijp.4038

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  4 in total

1.  Shear bond strength of indirect composite material to monolithic zirconia.

Authors:  Fatih Sari; Asli Secilmis; Irfan Simsek; Semih Ozsevik
Journal:  J Adv Prosthodont       Date:  2016-08-18       Impact factor: 1.904

Review 2.  A systematic review and meta-analysis evaluating the survival, the failure, and the complication rates of veneered and monolithic all-ceramic implant-supported single crowns.

Authors:  Bjarni Elvar Pjetursson; Irena Sailer; Andrey Latyshev; Kerstin Rabel; Ralf-Joachim Kohal; Duygu Karasan
Journal:  Clin Oral Implants Res       Date:  2021-10       Impact factor: 5.021

3.  Technical and Biological Complications of Screw-Retained (CAD/CAM) Monolithic and Partial Veneer Zirconia for Fixed Dental Prostheses on Posterior Implants Using a Digital Workflow: A 3-Year Cross-Sectional Retrospective Study.

Authors:  Paolo De Angelis; Giulio Gasparini; Francesca Camodeca; Silvio De Angelis; Margherita Giorgia Liguori; Edoardo Rella; Francesca Cannata; Antonio D'Addona; Paolo Francesco Manicone
Journal:  Biomed Res Int       Date:  2021-07-06       Impact factor: 3.411

4.  Patient Satisfaction with Implant-Supported Monolithic and Partially Veneered Zirconia Restorations.

Authors:  Paolo De Angelis; Giulio Gasparini; Edoardo Rella; Silvio De Angelis; Cristina Grippaudo; Antonio D'Addona; Paolo Francesco Manicone
Journal:  Biomed Res Int       Date:  2021-02-06       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.