Literature DB >> 25964710

Context-specific method for detection of soft-tissue lesions in non-cathartic low-dose dual-energy CT colonography.

Janne J Näppi1, Daniele Regge2, Hiroyuki Yoshida1.   

Abstract

In computed tomographic colonography (CTC), orally administered fecal-tagging agents can be used to indicate residual feces and fluid that could otherwise hide or imitate lesions on CTC images of the colon. Although the use of fecal tagging improves the detection accuracy of CTC, it can introduce image artifacts that may cause lesions that are covered by fecal tagging to have a different visual appearance than those not covered by fecal tagging. This can distort the values of image-based computational features, thereby reducing the accuracy of computer-aided detection (CADe). We developed a context-specific method that performs the detection of lesions separately on lumen regions covered by air and on those covered by fecal tagging, thereby facilitating the optimization of detection parameters separately for these regions and their detected lesion candidates to improve the detection accuracy of CADe. For pilot evaluation, the method was integrated into a dual-energy CADe (DE-CADe) scheme and evaluated by use of leave-one-patient-out evaluation on 66 clinical non-cathartic low-dose dual-energy CTC (DE-CTC) cases that were acquired at a low effective radiation dose and reconstructed by use of iterative image reconstruction. There were 22 colonoscopy-confirmed lesions ≥6 mm in size in 21 patients. The DE-CADe scheme detected 96% of the lesions at a median of 6 FP detections per patient. These preliminary results indicate that the use of context-specific detection can yield high detection accuracy of CADe in non-cathartic low-dose DE-CTC examinations.

Entities:  

Keywords:  Computer-aided detection; dual-energy CT; false-positive reduction; noncathartic preparation; polyp detection; virtual colonoscopy

Year:  2015        PMID: 25964710      PMCID: PMC4425267          DOI: 10.1117/12.2081284

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  13 in total

1.  Three-dimensional computer-aided diagnosis scheme for detection of colonic polyps.

Authors:  H Yoshida; J Näppi
Journal:  IEEE Trans Med Imaging       Date:  2001-12       Impact factor: 10.048

2.  Radiation dose reduction with Sinogram Affirmed Iterative Reconstruction technique for abdominal computed tomography.

Authors:  Mannudeep K Kalra; Mischa Woisetschläger; Nils Dahlström; Sarabjeet Singh; Maria Lindblom; Garry Choy; Petter Quick; Bernhard Schmidt; Martin Sedlmair; Michael A Blake; Anders Persson
Journal:  J Comput Assist Tomogr       Date:  2012 May-Jun       Impact factor: 1.826

Review 3.  Dual-energy CT-based monochromatic imaging.

Authors:  Lifeng Yu; Shuai Leng; Cynthia H McCollough
Journal:  AJR Am J Roentgenol       Date:  2012-11       Impact factor: 3.959

4.  Extraction of information from CT scans at different energies.

Authors:  M R Millner; W D McDavid; R G Waggener; M J Dennis; W H Payne; V J Sank
Journal:  Med Phys       Date:  1979 Jan-Feb       Impact factor: 4.071

5.  Dose reduction methods for CT colonography.

Authors:  Kevin J Chang; Judy Yee
Journal:  Abdom Imaging       Date:  2013-04

Review 6.  Screening and surveillance for the early detection of colorectal cancer and adenomatous polyps, 2008: a joint guideline from the American Cancer Society, the US Multi-Society Task Force on Colorectal Cancer, and the American College of Radiology.

Authors:  Bernard Levin; David A Lieberman; Beth McFarland; Kimberly S Andrews; Durado Brooks; John Bond; Chiranjeev Dash; Francis M Giardiello; Seth Glick; David Johnson; C Daniel Johnson; Theodore R Levin; Perry J Pickhardt; Douglas K Rex; Robert A Smith; Alan Thorson; Sidney J Winawer
Journal:  Gastroenterology       Date:  2008-02-08       Impact factor: 22.682

7.  Information-Preserving Pseudo-Enhancement Correction for Non-Cathartic Low-Dose Dual-Energy CT Colonography.

Authors:  Janne J Näppi; Rie Tachibana; Daniele Regge; Hiroyuki Yoshida
Journal:  Abdom Imaging (2014)       Date:  2014-09

8.  Volumetric detection of colorectal lesions for noncathartic dual-energy computed tomographic colonography.

Authors:  Janne J Näppi; Se Hyung Kim; Hiroyuki Yoshida
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2012

9.  Virtual tagging for laxative-free CT colonography: pilot evaluation.

Authors:  Janne Näppi; Hiroyuki Yoshida
Journal:  Med Phys       Date:  2009-05       Impact factor: 4.071

10.  Diagnostic accuracy of laxative-free computed tomographic colonography for detection of adenomatous polyps in asymptomatic adults: a prospective evaluation.

Authors:  Michael E Zalis; Michael A Blake; Wenli Cai; Peter F Hahn; Elkan F Halpern; Imrana G Kazam; Myles Keroack; Cordula Magee; Janne J Näppi; Rocio Perez-Johnston; John R Saltzman; Abhinav Vij; Judy Yee; Hiroyuki Yoshida
Journal:  Ann Intern Med       Date:  2012-05-15       Impact factor: 25.391

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.