Literature DB >> 25963896

Magnetic beads-based electrochemical immunosensor for monitoring allergenic food proteins.

Michaela Čadková1, Radovan Metelka2, Lucie Holubová1, Daniel Horák3, Veronika Dvořáková1, Zuzana Bílková1, Lucie Korecká4.   

Abstract

Screen-printed platinum electrodes as transducer and magnetic beads as solid phase were combined to develop a particle-based electrochemical immunosensor for monitoring the serious food allergen ovalbumin. The standard arrangement of enzyme-linked immunosorbent assay became the basis for designing the immunosensor. A sandwich-type immunocomplex was formed between magnetic particles functionalized with specific anti-ovalbumin immunoglobulin G and captured ovalbumin molecules, and secondary anti-ovalbumin antibodies conjugated with the enzyme horseradish peroxidase were subsequently added as label tag. The electrochemical signal proportional to the enzymatic reaction of horseradish peroxidase during the reduction of hydrogen peroxide with thionine as electron mediator was measured by linear sweep voltammetry. The newly established method of ovalbumin detection exhibits high sensitivity suitable for quantification in the range of 11 to 222nM and a detection limit of 5nM. Magnetic beads-based assay format using external magnets for rapid and simple separation has been proven to be an excellent basis for electrochemical detection and quantification of food allergens in highly complex sample matrices.
Copyright © 2015 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Electrochemical immunosensor; Magnetic particles; Ovalbumin

Mesh:

Substances:

Year:  2015        PMID: 25963896     DOI: 10.1016/j.ab.2015.04.037

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  3 in total

Review 1.  Electrochemical Affinity Biosensors Based on Disposable Screen-Printed Electrodes for Detection of Food Allergens.

Authors:  Alina Vasilescu; Gilvanda Nunes; Akhtar Hayat; Usman Latif; Jean-Louis Marty
Journal:  Sensors (Basel)       Date:  2016-11-05       Impact factor: 3.576

2.  Amperometric immunosensor developed for sensitive detection of SARS-CoV-2 spike S1 protein in combined with portable device.

Authors:  Arzum Erdem; Huseyin Senturk; Esma Yildiz; Meltem Maral
Journal:  Talanta       Date:  2022-03-29       Impact factor: 6.556

Review 3.  Magnetic Particles Coupled to Disposable Screen Printed Transducers for Electrochemical Biosensing.

Authors:  Paloma Yáñez-Sedeño; Susana Campuzano; José M Pingarrón
Journal:  Sensors (Basel)       Date:  2016-09-25       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.