Literature DB >> 25963318

Microsphere skimming in the porcine coronary arteries: Implications for flow quantification.

Matthew Sinclair1, Jack Lee1, Andreas Schuster2, Amedeo Chiribiri1, Jeroen van den Wijngaard3, Pepijn van Horssen3, Maria Siebes3, Jos A E Spaan3, Eike Nagel1, Nicolas P Smith4.   

Abstract

Particle skimming is a phenomenon where particles suspended in fluid flowing through vessels distribute disproportionately to bulk fluid volume at junctions. Microspheres are considered a gold standard of intra-organ perfusion measurements and are used widely in studies of flow distribution and quantification. It has previously been hypothesised that skimming at arterial junctions is responsible for a systematic over-estimation of myocardial perfusion from microspheres at the subendocardium. Our objective is to integrate coronary arterial structure and microsphere distribution, imaged at high resolution, to test the hypothesis of microsphere skimming in a porcine left coronary arterial (LCA) network. A detailed network was reconstructed from cryomicrotome imaging data and a Poiseuille flow model was used to simulate flow. A statistical approach using Clopper-Pearson confidence intervals was applied to determine the prevalence of skimming at bifurcations in the LCA. Results reveal that microsphere skimming is most prevalent at bifurcations in the larger coronary arteries, namely the epicardial and transmural arteries. Bifurcations at which skimming was identified have significantly more asymmetric branching parameters. This finding suggests that when using thin transmural segments to quantify flow from microspheres, a skimming-related deposition bias may result in underestimation of perfusion in the subepicardium, and overestimation in the subendocardium.
Copyright © 2015 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Coronary flow model; Microspheres; Perfusion quantification; Skimming

Mesh:

Substances:

Year:  2015        PMID: 25963318      PMCID: PMC7611146          DOI: 10.1016/j.mvr.2015.04.005

Source DB:  PubMed          Journal:  Microvasc Res        ISSN: 0026-2862            Impact factor:   3.514


  62 in total

1.  The flow of blood in narrow tubes. II. The axial stream and its formation, as determined by changes in optical density.

Authors:  M TAYLOR
Journal:  Aust J Exp Biol Med Sci       Date:  1955-02

2.  Plasma skimming in serial microvascular bifurcations.

Authors:  R T Carr; L L Wickham
Journal:  Microvasc Res       Date:  1990-09       Impact factor: 3.514

3.  Biophysical model of the spatial heterogeneity of myocardial flow.

Authors:  Yunlong Huo; Benjamin Kaimovitz; Yoram Lanir; Thomas Wischgoll; Julien I E Hoffman; Ghassan S Kassab
Journal:  Biophys J       Date:  2009-05-20       Impact factor: 4.033

4.  Perfusion territories subtended by penetrating coronary arteries increase in size and decrease in number toward the subendocardium.

Authors:  P van Horssen; J P H M van den Wijngaard; M J Brandt; I E Hoefer; J A E Spaan; M Siebes
Journal:  Am J Physiol Heart Circ Physiol       Date:  2013-12-20       Impact factor: 4.733

Review 5.  Noninvasive assessment of myocardial perfusion.

Authors:  Michael Salerno; George A Beller
Journal:  Circ Cardiovasc Imaging       Date:  2009-09       Impact factor: 7.792

Review 6.  Retrograde heart perfusion: the Langendorff technique of isolated heart perfusion.

Authors:  Robert M Bell; Mihaela M Mocanu; Derek M Yellon
Journal:  J Mol Cell Cardiol       Date:  2011-03-06       Impact factor: 5.000

7.  Relative flow of blood cells, platelets, and microspheres in outer and inner renal cortex.

Authors:  E S Ofjord; G Clausen
Journal:  Am J Physiol       Date:  1986-08

8.  Some sources of error in measuring regional blood flow with radioactive microspheres.

Authors:  G D Buckberg; J C Luck; D B Payne; J I Hoffman; J P Archie; D E Fixler
Journal:  J Appl Physiol       Date:  1971-10       Impact factor: 3.531

9.  Regional heterogeneity of myocardial perfusion in healthy human myocardium: assessment with magnetic resonance perfusion imaging.

Authors:  Olaf M Muehling; Michael Jerosch-Herold; Prasad Panse; Andrey Zenovich; Betsy V Wilson; Robert F Wilson; Norbert Wilke
Journal:  J Cardiovasc Magn Reson       Date:  2004       Impact factor: 5.364

10.  Estimation of absolute myocardial blood flow during first-pass MR perfusion imaging using a dual-bolus injection technique: comparison to single-bolus injection method.

Authors:  Timothy F Christian; Anthony H Aletras; Andrew E Arai
Journal:  J Magn Reson Imaging       Date:  2008-06       Impact factor: 4.813

View more
  3 in total

1.  Movement of a finite body in channel flow.

Authors:  Frank T Smith; Edward R Johnson
Journal:  Proc Math Phys Eng Sci       Date:  2016-07       Impact factor: 2.704

2.  Improved co-registration of ex-vivo and in-vivo cardiovascular magnetic resonance images using heart-specific flexible 3D printed acrylic scaffold combined with non-rigid registration.

Authors:  John Whitaker; Radhouene Neji; Nicholas Byrne; Esther Puyol-Antón; Rahul K Mukherjee; Steven E Williams; Henry Chubb; Louisa O'Neill; Orod Razeghi; Adam Connolly; Kawal Rhode; Steven Niederer; Andrew King; Cory Tschabrunn; Elad Anter; Reza Nezafat; Martin J Bishop; Mark O'Neill; Reza Razavi; Sébastien Roujol
Journal:  J Cardiovasc Magn Reson       Date:  2019-10-10       Impact factor: 5.364

3.  Pixel-wise assessment of cardiovascular magnetic resonance first-pass perfusion using a cardiac phantom mimicking transmural myocardial perfusion gradients.

Authors:  Xenios Milidonis; Muhummad Sohaib Nazir; Torben Schneider; Myles Capstick; Sita Drost; Gertjan Kok; Nikola Pelevic; Christian Poelma; Tobias Schaeffter; Amedeo Chiribiri
Journal:  Magn Reson Med       Date:  2020-05-19       Impact factor: 4.668

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.