Literature DB >> 25957763

An extraocular non-invasive transscleral LED-endoilluminator for eye speculum integration.

Philipp Simon Kölbl1, Christoph Lindner, Christian Lingenfelder, Svenja Deuchler, Pankaj Singh, Frank Koch, Martin Hessling.   

Abstract

PURPOSE: Conventional chandelier-endoilluminators used for pars-plana vitrectomy consist of a light-emitting tip attached to an optical fibre. The tip requires introduction into the ocular space through an incision. To achieve complete illumination of the intraocular space, the introduction of more than just one tip is sometimes necessary. An extraocular vitreoretinal LED-endoilluminator discussed in this paper represents a new approach to illuminate the intraocular space. The light source is integrated into a speculum and firmly apposed to the sclera. This approach offers the advantage of effectively illuminating the interior of the eye even though the procedure is non-invasive. Furthermore, this approach significantly reduces the risk of damage to the retina by phototoxic effects.
METHODS: A round white LED was used as a light source. By integrating the light source into a speculum, the LED was firmly held against the sclera. Thus, the ocular space was illuminated transsclerally. As a result, indirect uniform illumination of the complete intraocular space was achieved. The prototype was developed considering the relevant international standards. Porcine eyes were used because their properties are similar to those of human eyes.
RESULTS: Porcine eyes could be acceptably illuminated with the selected LED. The LED-endoilluminator conforms with international standards for endoillumination. Thus, possible photochemical and thermal risks are considered and reduced to a minimum.
CONCLUSIONS: A novel LED-endoilluminator which can be attached to a speculum was developed. The system does not need any connection to an external light source and, consequently, also avoids usage of an optical fibre. Regular and uniform illumination of the intraocular space was achieved by transmitted and scattered visible irradiation, avoiding an incision. The duration of potential light exposure, compared to existing illumination systems, can be significantly increased. This is also true when the illuminator is not directly placed over the pars-plana and the distance to the retina is reduced. Only a part of the light reaches the retina and the fraction of short wavelength becomes very small. Increased safety of the system results from now being able to increase the exposure time and reduce phototoxic stress to the retina.

Entities:  

Mesh:

Year:  2015        PMID: 25957763     DOI: 10.1007/s00417-015-3036-9

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  25 in total

Review 1.  [Cause and prevention of oxidative damage to the eye. Current knowledge].

Authors:  A J Augustin; H B Dick; A Winkgen; U Schmidt-Erfurth
Journal:  Ophthalmologe       Date:  2001-08       Impact factor: 1.059

2.  Twin lights: a new chandelier illumination for bimanual surgery.

Authors:  Claus Eckardt
Journal:  Retina       Date:  2003-12       Impact factor: 4.256

3.  Self-retaining 27-gauge transconjunctival chandelier endoillumination for panoramic viewing during vitreous surgery.

Authors:  Yusuke Oshima; Carl C Awh; Yasuo Tano
Journal:  Am J Ophthalmol       Date:  2006-08-28       Impact factor: 5.258

4.  Optical properties of human sclera, and their consequences for transscleral laser applications.

Authors:  A Vogel; C Dlugos; R Nuffer; R Birngruber
Journal:  Lasers Surg Med       Date:  1991       Impact factor: 4.025

Review 5.  [Exposure to light during vitreoretinal surgery. II: Characteristics of endoilluminators].

Authors:  T Ach; A E Höh; R Amberger; S Dithmar
Journal:  Ophthalmologe       Date:  2008-10       Impact factor: 1.059

6.  A 29/30-gauge dual-chandelier illumination system for panoramic viewing during microincision vitrectomy surgery.

Authors:  Hirokazu Sakaguchi; Yusuke Oshima; Kohji Nishida; Carl C Awh
Journal:  Retina       Date:  2011-06       Impact factor: 4.256

7.  Nitric oxide and lipid peroxidation are increased and associated with decreased antioxidant enzyme activities in patients with age-related macular degeneration.

Authors:  Cem Evereklioglu; Hamdi Er; Selim Doganay; Mustafa Cekmen; Yusuf Turkoz; Baris Otlu; Elif Ozerol
Journal:  Doc Ophthalmol       Date:  2003-03       Impact factor: 2.379

8.  Retinal sensitivity to damage from short wavelength light.

Authors:  W T Ham; H A Mueller; D H Sliney
Journal:  Nature       Date:  1976-03-11       Impact factor: 49.962

Review 9.  The role of oxidative stress in the pathogenesis of age-related macular degeneration.

Authors:  S Beatty; H Koh; M Phil; D Henson; M Boulton
Journal:  Surv Ophthalmol       Date:  2000 Sep-Oct       Impact factor: 6.048

10.  Guidelines on limits of exposure to broad-band incoherent optical radiation (0.38 to 3 microM). International Commission on Non-Ionizing Radiation Protection.

Authors: 
Journal:  Health Phys       Date:  1997-09       Impact factor: 1.316

View more
  3 in total

1.  Location and pressure dependent transmission of human and porcine sclera: an anterior to posterior examination.

Authors:  Philipp Simon Koelbl; Pia Klante; Frank Koch; Christian Lingenfelder; Jens Ulrich Werner; Christian Enders; Martin Hessling
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-08-05       Impact factor: 3.117

2.  [Ophthalmic diaphanoscopy].

Authors:  F H J Koch; S Deuchler; P Singh; M Heßling
Journal:  Ophthalmologe       Date:  2017-09       Impact factor: 1.059

3.  Trans-palpebral illumination: an approach for wide-angle fundus photography without the need for pupil dilation.

Authors:  Devrim Toslak; Damber Thapa; Yanjun Chen; Muhammet Kazim Erol; R V Paul Chan; Xincheng Yao
Journal:  Opt Lett       Date:  2016-06-15       Impact factor: 3.776

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.