| Literature DB >> 25955584 |
Alberto Gomez, Adelaide de Vecchi, Martin Jantsch, Wenzhe Shi, Kuberan Pushparajah, John M Simpson, Nicolas P Smith, Daniel Rueckert, Tobias Schaeffter, Graeme P Penney.
Abstract
We demonstrate a new method to recover 4D blood flow over the entire ventricle from partial blood velocity measurements using multiple 3D+t colour Doppler images and ventricular wall motion estimated using 3D+t BMode images. We apply our approach to realistic simulated data to ascertain the ability of the method to deal with incomplete data, as typically happens in clinical practice. Experiments using synthetic data show that the use of wall motion improves velocity reconstruction, shows more accurate flow patterns and improves mean accuracy particularly when coverage of the ventricle is poor. The method was applied to patient data from 6 congenital cases, producing results consistent with the simulations. The use of wall motion produced more plausible flow patterns and reduced the reconstruction error in all patients.Entities:
Mesh:
Year: 2015 PMID: 25955584 PMCID: PMC7115944 DOI: 10.1109/TMI.2015.2428932
Source DB: PubMed Journal: IEEE Trans Med Imaging ISSN: 0278-0062 Impact factor: 10.048