Literature DB >> 25952912

High early migration of the revised acetabular component is a predictor of late cup loosening: 312 cup revisions followed with radiostereometric analysis for 2-20 years.

Tina Klerken1, Maziar Mohaddes1, Szilard Nemes2, Johan Kärrholm1.   

Abstract

INTRODUCTION: Radiostereometric analysis (RSA) is an accurate and precise measurement tool of migration and rotation of implants. We investigated if early migration measured with RSA can be used to predict the risk of later aseptic loosening in acetabular revision surgery. PATIENTS AND METHODS: A total of 312 patients who underwent acetabular revision surgery were followed by RSA measurements for 2 to 20 years. The endpoint was either re-revision due to aseptic loosening or loosening on last available radiographic examination. Cox regression model was used to evaluate the predictive value of early migration.
RESULTS: A total of 16 acetabular cups were re-revised due to aseptic loosening and 7 unrevised cups were radiographically loose. Every mm of proximal migration 2 years postoperatively increased the risk of aseptic loosening by 37% (hazard ratio (HR) 1.37, 95% confidence interval (CI) 1.18-1.58). Adjusting for differences in base line demographics, bone defects and surgical techniques in a Cox regression model, risk of aseptic loosening with every mm of proximal migration was even higher (HR 1.94, 95% CI 1.34-2.82, p<0.001).
CONCLUSIONS: We found a strong relationship between early migration measured by RSA and risk of late aseptic loosening in acetabular revision surgery. Monitoring proximal migration with RSA should be considered as an essential step in quality assessment when new implants and novel techniques are introduced in acetabular revision surgery.

Entities:  

Mesh:

Year:  2015        PMID: 25952912     DOI: 10.5301/hipint.5000246

Source DB:  PubMed          Journal:  Hip Int        ISSN: 1120-7000            Impact factor:   2.135


  14 in total

1.  Early Subsidence Predicts Failure of a Cemented Femoral Stem With Minor Design Changes.

Authors:  Per-Erik Johanson; Martin Antonsson; Bita Shareghi; Johan Kärrholm
Journal:  Clin Orthop Relat Res       Date:  2016-10       Impact factor: 4.176

Review 2.  Experimental and Numerical Models of Complex Clinical Scenarios; Strategies to Improve Relevance and Reproducibility of Joint Replacement Research.

Authors:  Joan E Bechtold; Pascal Swider; Curtis Goreham-Voss; Kjeld Soballe
Journal:  J Biomech Eng       Date:  2016-02       Impact factor: 2.097

3.  Does a titanium-coated polyethylene press-fit cup give reliable midterm results?

Authors:  Nikki Hooper; Harry Sargeant; Chris Frampton; Gary Hooper
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

4.  Do Bone Graft and Cracking of the Sclerotic Cavity Improve Fixation of Titanium and Hydroxyapatite-coated Revision Implants in an Animal Model?

Authors:  Brian Elmengaard; Joergen Baas; Thomas Jakobsen; Soren Kold; Thomas B Jensen; Joan E Bechtold; Kjeld Soballe
Journal:  Clin Orthop Relat Res       Date:  2017-02       Impact factor: 4.176

5.  Does cup-cage reconstruction with oversized cups provide initial stability in THA for osteoporotic acetabular fractures?

Authors:  Lucian B Solomon; Patrick Studer; John M Abrahams; Stuart A Callary; Caroline R Moran; Roumen B Stamenkov; Donald W Howie
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

Review 6.  Hip prosthetic loosening and periprosthetic osteolysis: A commentary.

Authors:  Bengt Mjöberg
Journal:  World J Orthop       Date:  2022-06-18

7.  Early Migration Predicts Aseptic Loosening of Cementless Femoral Stems: A Long-term Study.

Authors:  Marcus R Streit; Daniel Haeussler; Thomas Bruckner; Tanja Proctor; Moritz M Innmann; Christian Merle; Tobias Gotterbarm; Stefan Weiss
Journal:  Clin Orthop Relat Res       Date:  2016-04-29       Impact factor: 4.176

8.  Does particle disease really exist?

Authors:  Bengt Mjöberg
Journal:  Acta Orthop       Date:  2017-09-15       Impact factor: 3.717

9.  The Use of Porous Titanium Coating and the Largest Possible Head Do Not Affect Early Cup Fixation: A 2-Year Report from a Randomized Controlled Trial.

Authors:  Georgios Tsikandylakis; Kristian R L Mortensen; Kirill Gromov; Anders Troelsen; Henrik Malchau; Maziar Mohaddes
Journal:  JB JS Open Access       Date:  2020-12-15

10.  Model-based roentgen stereophotogrammetric analysis using elementary geometrical shape models: 10 years results of an uncemented acetabular cup component.

Authors:  Anne Jacobsen; Frank Seehaus; Yutong Hong; Han Cao; Alexander Schuh; Raimund Forst; Stefan Sesselmann
Journal:  BMC Musculoskelet Disord       Date:  2018-09-18       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.