Literature DB >> 25952554

Biomechanical comparison of a transiliac internal fixator and two iliosacral screws in transforaminal sacral fractures: a finite element analysis.

Martin Salášek1,2, Magdalena Jansová2, Jiří Křen2, Tomáš Pavelka1, Drahomíra Weisová1,2.   

Abstract

PURPOSE: Vertically unstable sacral transforaminal fractures can be stabilized with a transiliac internal fixator (TIFI) or two iliosacral screws (IS). This study was designed to compare stiffness between TIFI and IS.
METHODS: Using CT images finite element model of the pelvis was developed. Denis II type fracture was simulated and fixed either with TIFI or two IS. The sacral base was loaded vertically (250-500 N), displacement magnitudes on medial and lateral fracture surface and the maximum bone stress were calculated. The intact pelvis was used as a reference. Stiffness was determined by linear regression of load and displacement, computed stiffness ratio %. The von Mises stress was expressed as % ratio, evaluation of colour mapping was made.
RESULTS: The mean stiffness ratio medially in TIFI was 75.22%, in IS 46.54% (p = 0.00005), laterally in TIFI 57.88%, in IS 44.74% ( p = 0.03996). The von Mises stress ratio of TIFI was 139.27%, of IS 565.35% ( p < 0.00001).
CONCLUSIONS: Significantly higher stiffness and lower stress were found in TIFI model. TIFI provides a lower risk of over-compression of the fracture line in comparison with IS. TIFI thus exhibits superiority for fixation of trans- foraminal fractures, particularly with comminutive zone.

Entities:  

Mesh:

Year:  2015        PMID: 25952554

Source DB:  PubMed          Journal:  Acta Bioeng Biomech        ISSN: 1509-409X            Impact factor:   1.073


  4 in total

1.  Comparison of Biomechanical Performance of Five Different Treatment Approaches for Fixing Posterior Pelvic Ring Injury.

Authors:  Yongtao Lu; Yiqian He; Weiteng Li; Zhuoyue Yang; Ruifei Peng; Li Yu
Journal:  J Healthc Eng       Date:  2020-01-22       Impact factor: 2.682

2.  Clinical and Patient-Related Outcome After Stabilization of Dorsal Pelvic Ring Fractures: A Retrospective Study Comparing Transiliac Fixator (TIFI) and Spinopelvic Fixation (SPF).

Authors:  Ricarda Johanna Seemann; Erik Hempel; Gabriele Rußow; Serafeim Tsitsilonis; Ulrich Stöckle; Sven Märdian
Journal:  Front Surg       Date:  2021-11-29

3.  Different Lengths of Percutaneous Transverse Iliosacral Screw in Geometric Osseous Fixation Pathway: A Finite-Element Analysis.

Authors:  Qiong Wu; Yuanzhi Zhang; Shaobai Wang; Rui Liu; Gang Liu
Journal:  Indian J Orthop       Date:  2022-06-01       Impact factor: 1.033

4.  Biomechanical study of anterior and posterior pelvic rings using pedicle screw fixation for Tile C1 pelvic fractures: Finite element analysis.

Authors:  Yuanzheng Song; Changsheng Shao; Ximing Yang; Feng Lin
Journal:  PLoS One       Date:  2022-08-25       Impact factor: 3.752

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.