Literature DB >> 25951620

Quantitative three-dimensional analysis of poly (lactic-co-glycolic acid) microsphere using hard X-ray nano-tomography revealed correlation between structural parameters and drug burst release.

Xiaozhou Huang1, Na Li2, Dajiang Wang3, Yuyan Luo1, Ziyu Wu4, Zhefei Guo1, Qixing Jin1, Zhuying Liu1, Yafei Huang1, Yongming Zhang5, Chuanbin Wu6.   

Abstract

The objective of this study was to investigate the use of transmission hard X-ray nano-computed-tomography (nano-CT) for characterization of the pore structure and drug distribution in poly (lactic-co-glycolic acid) (PLGA) microspheres encapsulating bovine serum albumin and to study the correlation between drug distribution and burst release. The PLGA microspheres were fabricated using a double-emulsion method. The results of pore structure analysis accessed with nano-CT were compared with those acquired by scanning electron microscopy (SEM) and confocal laser scanning microscopy (CLSM). Surface pore interconnectivity and surface protein interconnectivity were obtained using combined nano-CT and pixel analysis. The correlation between surface protein interconnectivity with the initial burst release across various tested formulations was also analyzed. The size, shape, and distribution of the pores and protein could be clearly observed in the whole microsphere using nano-CT, whereas only the sectional information was observed using SEM or CLSM. Interconnected pores and surface connected pores could be clearly distinguished in nano-CT, which enables the quantitative analysis of surface pore interconnectivity and surface protein interconnectivity. The surface protein interconnectivity in different formulations correlated well with the burst release at 5-10h. Nano-CT provided a nondestructive, high-resolution, and three-dimensional analysis method to characterize the porous microsphere.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  PLGA microspheres; Pore structure; Scanning electron microscopy (SEM); Surface protein interconnectivity; Transmission hard X-ray nano-tomography (nano-CT)

Mesh:

Substances:

Year:  2015        PMID: 25951620     DOI: 10.1016/j.jpba.2015.04.017

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  4 in total

1.  Toward a new insight of calcium oxalate stones in Drosophila by micro-computerized tomography.

Authors:  Wen-Chi Chen; Huey-Yi Chen; Po-Chi Liao; Shih-Jing Wang; Ming-Yen Tsai; Yung-Hsiang Chen; Wei-Yong Lin
Journal:  Urolithiasis       Date:  2017-03-04       Impact factor: 3.436

2.  The Use of Cellulose Membrane to Eliminate Burst Release from Intravaginal Rings.

Authors:  Ignacio M Helbling; Juan C D Ibarra; Julio A Luna
Journal:  AAPS J       Date:  2016-04-20       Impact factor: 4.009

3.  Three dimensional distribution of surfactant in microspheres revealed by synchrotron radiation X-ray microcomputed tomography.

Authors:  Li Wu; Manli Wang; Vikramjeet Singh; Haiyan Li; Zhen Guo; Shuangying Gui; Peter York; Tiqiao Xiao; Xianzhen Yin; Jiwen Zhang
Journal:  Asian J Pharm Sci       Date:  2017-02-15       Impact factor: 6.598

4.  Nano-CT as tool for characterization of dental resin composites.

Authors:  Håvard J Haugen; Saad B Qasim; Jukka P Matinlinna; Pekka Vallittu; Liebert Parreiras Nogueira
Journal:  Sci Rep       Date:  2020-09-23       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.