Literature DB >> 25948142

Performance of dental impression materials: Benchmarking of materials and techniques by three-dimensional analysis.

Heike Rudolph1, Michael R S Graf, Katharina Kuhn, Stephanie Rupf-Köhler, Alfred Eirich, Cornelia Edelmann, Sebastian Quaas, Ralph G Luthardt.   

Abstract

Among other factors, the precision of dental impressions is an important and determining factor for the fit of dental restorations. The aim of this study was to examine the three-dimensional (3D) precision of gypsum dies made using a range of impression techniques and materials. Ten impressions of a steel canine were fabricated for each of the 24 material-method-combinations and poured with type 4 die stone. The dies were optically digitized, aligned to the CAD model of the steel canine, and 3D differences were calculated. The results were statistically analyzed using one-way analysis of variance. Depending on material and impression technique, the mean values had a range between +10.9/-10.0 µm (SD 2.8/2.3) and +16.5/-23.5 µm (SD 11.8/18.8). Qualitative analysis using colorcoded graphs showed a characteristic location of deviations for different impression techniques. Three-dimensional analysis provided a comprehensive picture of the achievable precision. Processing aspects and impression technique were of significant influence.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25948142     DOI: 10.4012/dmj.2014-197

Source DB:  PubMed          Journal:  Dent Mater J        ISSN: 0287-4547            Impact factor:   2.102


  4 in total

1.  In vivo precision of conventional and digital methods for obtaining quadrant dental impressions.

Authors:  Andreas Ender; Moritz Zimmermann; Thomas Attin; Albert Mehl
Journal:  Clin Oral Investig       Date:  2015-11-07       Impact factor: 3.573

2.  Accuracy of triangular meshes of stone models created from DICOM cone beam CT data.

Authors:  Dimitrios Apostolakis; Georgios Michelinakis; Georgios Kourakis; Emmanuel Pavlakis
Journal:  Int J Implant Dent       Date:  2019-05-08

3.  Accuracy of intraoral and extraoral digital data acquisition for dental restorations.

Authors:  Heike Rudolph; Harald Salmen; Matthias Moldan; Katharina Kuhn; Viktor Sichwardt; Bernd Wöstmann; Ralph Gunnar Luthardt
Journal:  J Appl Oral Sci       Date:  2016 Jan-Feb       Impact factor: 2.698

4.  Reliability of light microscopy and a computer-assisted replica measurement technique for evaluating the fit of dental copings.

Authors:  Heike Rudolph; Silke Ostertag; Michael Ostertag; Michael H Walter; Ralph Gunnar Luthardt; Katharina Kuhn
Journal:  J Appl Oral Sci       Date:  2018-02-01       Impact factor: 2.698

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.