Literature DB >> 25947278

COmplex coronary Bifurcation lesions: RAndomized comparison of a strategy using a dedicated self-expanding biolimus-eluting stent versus a culotte strategy using everolimus-eluting stents: primary results of the COBRA trial.

Christophe Dubois1, Johan Bennett, Joseph Dens, Dries De Cock, Walter Desmet, Ann Belmans, Giovanni J Ughi, Peter Sinnaeve, Mathias Vrolix, Jan D'hooge, Tom Adriaenssens.   

Abstract

AIMS: We aimed to compare healing responses with optical coherence tomography, and clinical and angiographic outcome after treatment of coronary bifurcation lesions with a dedicated stent versus a conventional culotte technique. METHODS AND
RESULTS: Forty patients with true and complex coronary bifurcation lesions were randomly assigned to treatment with the Axxess™ bifurcation stent in the proximal main vessel (MV) and additional BioMatrix™ stents in the branches (Biosensors Europe SA, Morges, Switzerland), versus a culotte technique using XIENCE™ stents (Abbott Vascular, Santa Clara, CA, USA). The primary endpoint of percentage of uncovered struts at nine months was similar with the dedicated strategy vs. culotte in the proximal MV (median 17.8 [IQR 3.3-24.7] vs. 6.8 [2.0-20.5]; p=0.19), bifurcation core (9.5 [5.7-19.5] vs. 4.0 [0.7-17.6]; p=0.17), distal MV (2.6 [2.3-18] vs. 2.2 [0.5-6.0]; p=0.09) and side branch (5.7 [1.5-11.5] vs. 1.9 [0-5.8]; p=0.14). As compared with culotte, a strategy using Axxess resulted in a significantly larger lumen in the proximal MV both acutely (minimum lumen diameter 3.03±0.51 vs. 2.71±0.44 mm, p=0.04) and at follow-up (mean lumen area 10.0±2.1 vs. 7.1±1.8 mm2, p<0.001), and in a lower angiographic late lumen loss (p=0.05). Both strategies resulted in good clinical outcomes at one year, and no stent thromboses.
CONCLUSIONS: As compared with a culotte strategy with XIENCE stents, complex bifurcation stenting using a dedicated strategy combining Axxess and BioMatrix stents results in similar stent strut coverage at nine-month follow-up, and a significantly larger lumen and lower angiographic late lumen loss in the proximal MV.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 25947278     DOI: 10.4244/EIJY15M05_02

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  4 in total

1.  Coronary bifurcation lesions: is less more?

Authors:  Johan Bennett; Christophe Dubois
Journal:  J Thorac Dis       Date:  2016-10       Impact factor: 2.895

Review 2.  Percutaneous Coronary Intervention for Bifurcation: How Can We Outperform the Provisional Strategy?

Authors:  Andrew Kei-Yan Ng; Man-Hong Jim
Journal:  Clin Cardiol       Date:  2016-08-24       Impact factor: 2.882

3.  AXXESS™ Stent: Delivery Indications and Outcomes.

Authors:  John Rawlins; Jehangir Din; Suneel Talwar; Peter O'Kane
Journal:  Interv Cardiol       Date:  2015-05

4.  The Need For Dedicated Bifurcation Stents: A Critical Analysis.

Authors:  Maciej Lesiak
Journal:  Interv Cardiol       Date:  2016-10
  4 in total