Literature DB >> 25945603

A retrospective study of palindrome symmetrical-tip catheters for chronic hemodialysis access in China.

Chaoyang Ye1, Zhiguo Mao1, Pan Zhang1, Yuqiang Zhang1, Shu Rong1, Jing Chen1, Changlin Mei1.   

Abstract

Hemodialysis catheters remain necessary for long-term vascular access in patients for whom arteriovenous access may be problematic or impossible. Developments in catheter design have improved long-term catheter functionality, and reduced the rate of infection and complications associated with their use. This retrospective study of 284 cases of chronic catheterization in 271 patients treated between 2009 and 2011 using Tal Palindrome™ symmetrical-tip (N = 118) or Quinton™ Permcath™ step-tip (N = 166) hemodialysis catheters evaluates the efficacy and the safety of symmetrical-tip dialysis catheters for chronic hemodialysis, compared with a step-tip catheter. Measurements of catheter performance included mean catheter dwell time, incidence of low blood flow, and rates of infection and catheter-related blood stream infection (CRBSI). The symmetrical-tip catheter had a significantly longer mean dwell time compared with the step-tip catheter; 329.4 ± 38.1 versus 273.1 ± 25.4 d (p < 0.05). In addition, the rate of occurrence of low blood flow per 1000 catheter days was lower for the symmetrical-tip compared with the step-tip catheter; 1.13 versus 6.86 (p < 0.01). The symmetrical-tip catheter was also associated with a lower incidence of complications; the rates of infection (0.28 vs. 0.78; p < 0.01) and CRBSI (0.15 vs. 0.44; p < 0.01) were lower compared with those for step-tip catheters, and catheter removal occurred less often for the symmetrical-tip catheter (8% vs. 16%; p < 0.05). The symmetrical-tip hemodialysis catheter was associated with a longer mean dwell time, lower incidence of low blood flow, and lower infection rate compared with the step-tip catheter.

Entities:  

Keywords:  Catheters; catheter-related infections; renal dialysis; retrospective studies; vascular access devices

Mesh:

Year:  2015        PMID: 25945603     DOI: 10.3109/0886022X.2015.1040338

Source DB:  PubMed          Journal:  Ren Fail        ISSN: 0886-022X            Impact factor:   2.606


  1 in total

1.  Initial Clinical Experience with a Symmetric Tip Tunneled Hemodialysis Catheter Without Side Holes.

Authors:  Michael G Tal; Alexander S Yevzlin
Journal:  ASAIO J       Date:  2021-11-01       Impact factor: 2.872

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.