Influence of F0 and Sequence Length of Audio and Electroglottographic Signals on Perturbation Measures for Voice Assessment.

Julian Hohm1, Michael Döllinger1, Christopher Bohr1, Stefan Kniesburges1, Anke Ziethe2.   

Abstract

OBJECTIVE: Within the functional assessment of voice disorders, an objective analysis of measured parameters from audio, electroglottographic (EGG), or visual signals is desired. In a typical clinical situation, reliable objective analysis is not always possible due to missing standardization and unknown stability of the clinical parameters. The aim of this study was to investigate the robustness/stability of measured clinical parameters of the audio and EGG signals in a typical clinical setting to ensure a reliable objective analysis. In particular, the influence of F0 and of the sequence length on several definitions of jitter and shimmer will be analyzed. PATIENTS AND METHODS: Seventy-four young healthy women produced a sustained vowel /a/ and an upward triad with abrupt changeovers. Different sequence lengths (100, 150, 500, and 1000 ms) of sustained phonation and triads (100 and 150 ms) were extracted from the audio and EGG signals. In total, six variations of jitter and four variations of shimmer parameters were analyzed.
RESULTS: Jitter%, Jitter11p, and JitterPPQ of the audio signal as well as Jittermean, Shimmer, and Shimmer11p of the EGG signal are unaffected by both sequence length and F0.
CONCLUSIONS: Influence of F0 and sequence length on several perturbation measures of the audio and EGG signals was identified. For an objective clinical voice assessment, unaffected definitions of jitter and shimmer should be preferred and applied to enable comparability between different recordings, examinations, and studies.
Copyright © 2015 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Acoustic analysis; EGG; Perturbation measures; Voice assessment

Mesh:

Year:  2015        PMID: 25944290     DOI: 10.1016/j.jvoice.2014.10.001

Source DB:  PubMed          Journal:  J Voice        ISSN: 0892-1997            Impact factor:   2.009


  3 in total

1.  Laryngeal High-Speed Videoendoscopy: Sensitivity of Objective Parameters towards Recording Frame Rate.

Authors:  Anne Schützenberger; Melda Kunduk; Michael Döllinger; Christoph Alexiou; Denis Dubrovskiy; Marion Semmler; Anja Seger; Christopher Bohr
Journal:  Biomed Res Int       Date:  2016-11-21       Impact factor: 3.411

2.  Influence of spatial camera resolution in high-speed videoendoscopy on laryngeal parameters.

Authors:  Patrick Schlegel; Melda Kunduk; Michael Stingl; Marion Semmler; Michael Döllinger; Christopher Bohr; Anne Schützenberger
Journal:  PLoS One       Date:  2019-04-22       Impact factor: 3.240

3.  Interdependencies between acoustic and high-speed videoendoscopy parameters.

Authors:  Patrick Schlegel; Andreas M Kist; Melda Kunduk; Stephan Dürr; Michael Döllinger; Anne Schützenberger
Journal:  PLoS One       Date:  2021-02-02       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.