Literature DB >> 25940379

Functional and structural comparisons of the arthroscopic knotless double-row suture bridge and single-row repair for anterosuperior rotator cuff tears.

Junji Ide1, Tatsuki Karasugi2, Nobukazu Okamoto2, Takuya Taniwaki2, Kiyoshi Oka2, Hiroshi Mizuta2.   

Abstract

BACKGROUND: We compared the outcomes of knotless double-row suture bridge and single-row repairs in patients undergoing arthroscopic repair for anterosuperior rotator cuff tears.
METHODS: We included 61 full-thickness anterosuperior rotator cuff tears treated by arthroscopic repair, namely, single-row repair (group 1: 25 shoulders; mean patient age, 64 years) and the knotless double-row suture bridge repair (group 2: 36 shoulders; mean patient age, 62 years). Preoperative and postoperative magnetic resonance imaging was performed for all shoulders. Clinical outcomes were evaluated for mean follow-up periods of 81 months (range, 72-96 months) in group 1 and 34 months (range, 24-42 months) in group 2, using the University of California, Los Angeles and Japanese Orthopaedic Association assessments.
RESULTS: At the final follow-up, both groups showed improvement in the average University of California, Los Angeles and Japanese Orthopaedic Association scores and range of motion, although no intergroup differences were observed. Both groups showed improved abduction strength, and the average score was higher in group 2 (P = .0112). The lift-off and belly-press test results were improved in both groups. Postoperatively, the incidence of positive lift-off tests tended to be lower (P = .075) and that of positive belly-press tests was lower in group 2, P = .049). The repair failure rate tended to be lower in group 2 (14% [5 of 36]) than in group 1 (32% [8 of 25]; P = .0839).
CONCLUSIONS: Arthroscopic knotless double-row suture bridge repair of anterosuperior rotator cuff tears yielded functional outcomes equivalent to those of single-row repair and may be useful for improving subscapularis function, abduction strength, and tendon healing.
Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Knotless double-row suture bridge repair; anterosuperior rotator cuff tear; single-row repair

Mesh:

Year:  2015        PMID: 25940379     DOI: 10.1016/j.jse.2015.03.015

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  19 in total

1.  Medialization of medial row anchor via the Nevasier portal yield enhanced footprint and outcomes in medium-to-large rotator cuff tears.

Authors:  Seung-Bae Oh; Jae-Jung Jeong; Jong-Hun Ji; Kaushal Patel; Won-Ha Hwang; Joon-Hyung Cho
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-08-02       Impact factor: 4.342

2.  [Arthroscopic double-row reconstruction of high-grade subscapularis tendon tears].

Authors:  F Plachel; S Pauly; P Moroder; M Scheibel
Journal:  Oper Orthop Traumatol       Date:  2018-03-22       Impact factor: 1.154

3.  Postoperative residual pain is associated with a high magnetic resonance imaging (MRI)-based signal intensity of the repaired supraspinatus tendon.

Authors:  Hong Li; Yuzhou Chen; Shiyi Chen
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-08-26       Impact factor: 4.342

Review 4.  Current concepts review in the management of subscapularis tears.

Authors:  Girinivasan Chellamuthu; Shyam Sundar; David V Rajan
Journal:  J Clin Orthop Trauma       Date:  2022-04-12

5.  Biomechanical Comparison of Modified Suture Bridge Using Rip-Stop versus Traditional Suture Bridge for Rotator Cuff Repair.

Authors:  ZiYing Wu; Chong Zhang; Peng Zhang; TianWu Chen; ShiYi Chen; JiWu Chen
Journal:  Biomed Res Int       Date:  2016-11-15       Impact factor: 3.411

6.  Clinical outcomes and repair integrity of arthroscopic rotator cuff repair using suture-bridge technique with or without medial tying: prospective comparative study.

Authors:  Kyung Cheon Kim; Hyun Dae Shin; Woo-Yong Lee; Kyu-Woong Yeon; Sun-Cheol Han
Journal:  J Orthop Surg Res       Date:  2018-08-28       Impact factor: 2.359

7.  Prognostic factors affecting clinical outcomes after arthroscopic rotator cuff repair: importance of functional recovery by 3 months after surgery.

Authors:  Yosuke Nakamura; Masafumi Gotoh; Yasuhiro Mitsui; Hidehiro Nakamura; Hiroki Ohzono; Takahiro Okawa; Naoto Shiba
Journal:  J Orthop Surg Res       Date:  2018-12-05       Impact factor: 2.359

8.  Subscapularis tendon tears: Management and arthroscopic repair.

Authors:  Brett A Lenart; Jonathan B Ticker
Journal:  EFORT Open Rev       Date:  2017-12-15

9.  All-Extra-articular Repair of Anterosuperior Rotator Cuff Tears.

Authors:  Malte Holschen; Kai-Axel Witt; Jörn Steinbeck
Journal:  Arthrosc Tech       Date:  2018-01-01

10.  Clinical outcomes of arthroscopic rotator cuff repair: a retrospective comparison of double-layer, double-row and suture bridge methods.

Authors:  Hironori Kakoi; Toshihiko Izumi; Yasunari Fujii; Satoshi Nagano; Takao Setoguchi; Yasuhiro Ishidou; Setsuro Komiya
Journal:  BMC Musculoskelet Disord       Date:  2018-09-11       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.