Literature DB >> 25939966

Can Intraoperative Transesophageal Echocardiography Predict Postoperative Aortic Insufficiency in Patients Receiving Implantable Left Ventricular Assist Devices?

Suzanne E Kellman1, Andrew J Feider2, Valluvan Jeevanandam3, Mark A Chaney4.   

Abstract

OBJECTIVE: Aortic insufficiency (AI) develops in 25% of patients after left ventricular assist device (LVAD) insertion. The objective of this study was to evaluate the occurrence of new-onset AI upon initiation of cardiopulmonary bypass (CPB) required for LVAD insertion and the potential ability of this new-onset AI to predict development of post-LVAD insertion AI.
DESIGN: Forty-one patients undergoing LVAD insertion were studied. Intraoperative transesophageal echocardiography (TEE) evaluation was performed at baseline (post-induction, pre-sternotomy), 5 minutes after CPB initiation, and post-chest closure. Patients were followed up postoperatively for development of AI.
SETTING: Single university hospital. PARTICIPANTS: Patients undergoing elective LVAD insertion.
INTERVENTIONS: None.
MEASUREMENTS AND MAIN RESULTS: At baseline, 35 patients exhibited none-trace AI, 4 exhibited mild AI, 2 exhibited moderate AI, and none exhibited severe AI. After initiation of CPB, 34 patients exhibited no change in degree of AI yet 7 exhibited an increase in AI severity. However, all 7 patients exhibited no change in degree of AI at chest closure and one exhibited a decrease in AI severity. Four patients developed at least moderate AI during the postoperative period (range 3-8 months). However, only one of these patients exhibited an increase in AI severity after initiation of CPB for LVAD insertion. No significant changes in aortic root measurements were observed during the entire intraoperative period (within patients nor between patients with/without development of at least moderate postoperative AI).
CONCLUSIONS: One in 5 patients undergoing LVAD insertion will demonstrate an increase in AI severity at CPB initiation without changes in aortic root measurements. None of the information obtained from intraoperative TEE seemed to predict development of at least moderate postoperative AI.
Copyright © 2015. Published by Elsevier Inc.

Entities:  

Keywords:  aortic insufficiency; left ventricular assist device

Mesh:

Year:  2015        PMID: 25939966     DOI: 10.1053/j.jvca.2015.01.004

Source DB:  PubMed          Journal:  J Cardiothorac Vasc Anesth        ISSN: 1053-0770            Impact factor:   2.628


  2 in total

Review 1.  [Intensive care treatment of patients with left ventricular assist devices].

Authors:  B Steinlechner; Daniel Zimpfer; Arno Schiferer; Nikolaus Heinrich; Thomas Schlöglhofer; Angela Rajek; Martin Dworschak; Michael Hiesmayr
Journal:  Med Klin Intensivmed Notfmed       Date:  2015-08-28       Impact factor: 0.840

Review 2.  Role of Echocardiography in the Evaluation of Left Ventricular Assist Devices: the Importance of Emerging Technologies.

Authors:  Luca Longobardo; Christopher Kramer; Scipione Carerj; Concetta Zito; Renuka Jain; Valentin Suma; Vinay Thohan; Nasir Sulemanjee; Frank X Downey; Bijoy K Khandheria
Journal:  Curr Cardiol Rep       Date:  2016-07       Impact factor: 2.931

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.