Literature DB >> 25935337

Evaluation of uveal and capsule biocompatibility of a single-piece hydrophobic acrylic intraocular lens with ultraviolet-ozone treatment on the posterior surface.

M Aabid Farukhi1, Liliana Werner2, Justin C Kohl1, Gareth L Gardiner1, Joshua R Ford1, Scott C Cole1, Shail A Vasavada1, Rozina Noristani1, Nick Mamalis1.   

Abstract

PURPOSE: To evaluate a single-piece hydrophobic acrylic intraocular lens (IOL) with ultraviolet-ozone (UV-O3) treatment on the posterior surface and compare it with an identical untreated IOL in a rabbit model.
SETTING: John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA.
DESIGN: Experimental study.
METHODS: Study IOLs were implanted in the right eyes and control IOLs in the left eyes of 10 New Zealand rabbits. Slitlamp examinations were performed 1 to 6 weeks postoperatively. Neodymium:YAG (Nd:YAG) posterior capsulotomy was performed in both eyes of 5 rabbits after the 4-week slitlamp examination. At 6 weeks, the rabbits were killed humanely and their globes were enucleated. Capsular bag opacification was scored from the posterior aspect (Miyake-Apple view), and the eyes were processed for histopathology.
RESULTS: At 4 weeks, the mean posterior capsule opacification (PCO) scores were 0.88 ± 0.33 (SD) in the study eyes and 2.55 ± 1.13 in the control eyes (P=.003, 2-tailed paired t test). Performance of Nd:YAG posterior capsulotomy was similar in both groups. Gross postmortem examination also showed statistically less peripheral PCO in eyes with the study IOLs than in control eyes. There was no difference in histopathologic findings between study eyes and control eyes and no signs of untoward inflammation or toxicity in any eye evaluated.
CONCLUSIONS: Treatment of the posterior surface of a single-piece hydrophobic acrylic IOL with UV-O3 appears to prevent PCO, likely by increasing adhesion between the posterior capsule and the IOL while retaining uveal biocompatibility. Performance of Nd:YAG posterior capsulotomy was similar between treated IOLs and untreated IOLs.
Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25935337     DOI: 10.1016/j.jcrs.2014.11.043

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  3 in total

Review 1.  A Critical Appraisal of New Developments in Intraocular Lens Modifications and Drug Delivery Systems for the Prevention of Cataract Surgery Complications.

Authors:  Ioanna Mylona; Ioannis Tsinopoulos
Journal:  Pharmaceuticals (Basel)       Date:  2020-12-08

Review 2.  Research Progress Concerning a Novel Intraocular Lens for the Prevention of Posterior Capsular Opacification.

Authors:  Yidong Zhang; Chengshou Zhang; Silong Chen; Jianghua Hu; Lifang Shen; Yibo Yu
Journal:  Pharmaceutics       Date:  2022-06-25       Impact factor: 6.525

3.  Accuracy of the Barrett Universal II formula integrated into a commercially available optical biometer when using a preloaded single-piece intraocular lens.

Authors:  Hiroki Mieno; Osamu Hieda; Toshihide Ikeda; Shino Hayashi; Masatsugu Hashida; Kimiaki Urabe; Chie Sotozono
Journal:  Indian J Ophthalmol       Date:  2021-09       Impact factor: 1.848

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.