Literature DB >> 25935226

Atrial fibrillation ablation using remote magnetic navigation and the risk of atrial-esophageal fistula: international multicenter experience.

Asaf Danon1, Mohammed Shurrab, Krishnakumar Mohanan Nair, Decebal Gabriel Latcu, Mauricio S Arruda, Xu Chen, Tamas Szili-Torok, Ole Rossvol, Eric E Wissner, Ilan Lashevsky, Eugene Crystal.   

Abstract

PURPOSE: Remote magnetic navigation (RMN) has been used in various electrophysiological procedures, including atrial fibrillation (AF) ablation. Atrial-esophageal fistula (AEF) is one of most disastrous complications of AF ablation. We aimed to evaluate the incidence of AEF during AF ablation using RMN in comparison to manual ablation.
METHODS: We conducted the first international survey among RMN operators for assessment of the prevalence of AEF and procedural parameters affecting the risk. Data from parallel survey of AEF among Canadian interventional electrophysiologists (CIE) using only manual catheters served as control.
RESULTS: Fifteen RMN operators (who performed 3637 procedures) and 25 manual CIE operators (7016 procedures) responded to the survey. RMN operators were more experienced than CIE operators (16.3 ± 8.3 vs. 9.2 ± 5.4 practice years in electrophysiology, p = 0.007). The maximal energy output in the posterior wall was higher in the operator using RMN (33 ± 5 vs. 28.6 ± 4.9 W; p = 0.02). Other parameters including use of preprocedural images, irrigated catheter, pump flow rate, esophageal temperature monitoring, intracardiac echocardiography (ICE), and general anesthesia were similar. CIE operators administered proton-pump inhibitors postoperatively significantly more than RMN operators (76 vs. 35%, p = 0.01). AEF was reported in 5 of the 7016 patients in the control group (0.07%) but in none of the RMN group (p = 0.11).
CONCLUSIONS: AEF is a rare complication and its evaluation necessitates large-scale studies. Although no AEF case with RMN was reported in this large study or previously on the literature, the rarity of this complication prevents firm conclusion about the risk.

Entities:  

Mesh:

Year:  2015        PMID: 25935226     DOI: 10.1007/s10840-015-0003-7

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  20 in total

Review 1.  Management of atrial fibrillation in patients with structural heart disease.

Authors:  Andrew E Darby; John P Dimarco
Journal:  Circulation       Date:  2012-02-21       Impact factor: 29.690

Review 2.  Prophylactic proton pump inhibition after atrial fibrillation ablation: is there any evidence?

Authors:  Stephan Zellerhoff; Frank Lenze; Lars Eckardt
Journal:  Europace       Date:  2011-05-11       Impact factor: 5.214

3.  Worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation.

Authors:  Riccardo Cappato; Hugh Calkins; Shih-Ann Chen; Wyn Davies; Yoshito Iesaka; Jonathan Kalman; You-Ho Kim; George Klein; Douglas Packer; Allan Skanes
Journal:  Circulation       Date:  2005-02-21       Impact factor: 29.690

4.  The prevalence and risk factors for atrioesophageal fistula after percutaneous radiofrequency catheter ablation for atrial fibrillation: the Canadian experience.

Authors:  Krishna Kumar Mohanan Nair; Mohammed Shurrab; Allan Skanes; Asaf Danon; David Birnie; Carlos Morillo; Vijay Chauhan; Iqwal Mangat; Felix Ayala-Paredes; Jean Champagne; Isabelle Nault; Anthony Tang; Atul Verma; Ilan Lashevsky; Sheldon M Singh; Eugene Crystal
Journal:  J Interv Card Electrophysiol       Date:  2013-12-07       Impact factor: 1.900

5.  Robotic magnetic navigation for atrial fibrillation ablation.

Authors:  Carlo Pappone; Gabriele Vicedomini; Francesco Manguso; Filippo Gugliotta; Patrizio Mazzone; Simone Gulletta; Nicoleta Sora; Simone Sala; Alessandra Marzi; Giuseppe Augello; Laura Livolsi; Andreina Santagostino; Vincenzo Santinelli
Journal:  J Am Coll Cardiol       Date:  2006-03-15       Impact factor: 24.094

6.  Impact of remote magnetic catheter navigation on ablation fluoroscopy and procedure time.

Authors:  Albert M Kim; Mintu Turakhia; Jonathan Lu; Nitish Badhwar; Byron K Lee; Randall J Lee; Gregory M Marcus; Zian H Tseng; Melvin Scheinman; Jeffrey E Olgin
Journal:  Pacing Clin Electrophysiol       Date:  2008-11       Impact factor: 1.976

7.  Magnetic guidance system for cardiac electrophysiology: a prospective trial of safety and efficacy in humans.

Authors:  Mitchell N Faddis; Jane Chen; Judy Osborn; Michael Talcott; Michael E Cain; Bruce D Lindsay
Journal:  J Am Coll Cardiol       Date:  2003-12-03       Impact factor: 24.094

8.  Feasibility and safety of using an esophageal protective system to eliminate esophageal thermal injury: implications on atrial-esophageal fistula following AF ablation.

Authors:  Mauricio S Arruda; Luciana Armaganijan; Luigi Di Biase; Rassoll Rashidi; Andrea Natale
Journal:  J Cardiovasc Electrophysiol       Date:  2009-06-30

9.  Esophageal injury and temperature monitoring during atrial fibrillation ablation.

Authors:  Sheldon M Singh; Andre d'Avila; Shephal K Doshi; William R Brugge; Rudolph A Bedford; Theofanie Mela; Jeremy N Ruskin; Vivek Y Reddy
Journal:  Circ Arrhythm Electrophysiol       Date:  2008-08

10.  Mechanical displacement of the esophagus in patients undergoing left atrial ablation of atrial fibrillation.

Authors:  Aman Chugh; Joel Rubenstein; Eric Good; Matthew Ebinger; Krit Jongnarangsin; Jackie Fortino; Frank Bogun; Frank Pelosi; Hakan Oral; Timothy Nostrant; Fred Morady
Journal:  Heart Rhythm       Date:  2008-12-07       Impact factor: 6.343

View more
  4 in total

Review 1.  Atrial Fibrillation Ablation Using Magnetic Navigation Comparison With Conventional Approach During Long-Term Follow-Up.

Authors:  Tolga Aksu; Serdar Bozyel; Ebru Golcuk; Kývanc Yalin; Tumer Erdem Guler
Journal:  J Atr Fibrillation       Date:  2015-10-31

Review 2.  Impact of Contact Force Technology on Atrial Fibrillation Ablation: A Meta-Analysis.

Authors:  Mohammed Shurrab; Luigi Di Biase; David F Briceno; Anna Kaoutskaia; Saleem Haj-Yahia; David Newman; Ilan Lashevsky; Hiroshi Nakagawa; Eugene Crystal
Journal:  J Am Heart Assoc       Date:  2015-09-21       Impact factor: 5.501

Review 3.  Treatment strategy for treating atrial-esophageal fistula: esophageal stenting or surgical repair?: A case report and literature review.

Authors:  Bing Zhou; Xue-Jiang Cen; Lin-Yan Qian; Jie Pang; Hai Zou; Ya-Hui Ding
Journal:  Medicine (Baltimore)       Date:  2016-10       Impact factor: 1.889

4.  Comparisons of efficacy, safety, and recurrence risk factors of paroxysmal and persistent atrial fibrillation catheter ablation using robotic magnetic navigation system.

Authors:  Xiao-Xi Zhao; Ku-Lin Li; Ru-Xing Wang; Jie Zheng; Xiao-Yu Liu; Shi-Peng Dang; Zhi-Ming Yu; Chang-Ying Zhang; Xiang-Jun Yang
Journal:  Clin Cardiol       Date:  2019-03-15       Impact factor: 2.882

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.