Literature DB >> 25934786

Endovascular biopsy: Technical feasibility of novel endothelial cell harvesting devices assessed in a rabbit aneurysm model.

Daniel L Cooke1, Diana Bauer2, Zhengda Sun3, Carol Stillson3, Jeffrey Nelson4, David Barry5, Steven W Hetts3, Randall T Higashida6, Christopher F Dowd6, Van V Halbach6, Hua Su4, Maythem M Saeed3.   

Abstract

The lack of safe and reliable methods to sample vascular tissue in situ limits discovery of the underlying genetic and pathophysiological mechanisms of many vascular disorders, including aneurysms. We investigated the feasibility and comparable efficacy of in vivo vascular endothelial cell sampling using a spectrum of endovascular devices. Using the rabbit elastase carotid aneurysm model we evaluated the performance of existing aneurysmal coils, intracranial stents, and stent-like devices to collect vascular endothelial cells. Additionally, we modified a subset of devices to assess the effects of alterations to coil pitch, coil wire contour, and stent surface finishing. Device performance was evaluated by (1) the number of viable endothelial cells harvested, (2) the degree of vascular wall damage analyzed using digital subtraction angiography and histopathological analysis, and (3) the ease of device navigability and retrieval. Isolated cells underwent immunohistochemical analysis to confirm cell type and viability. Coil and stent specifications, technique, and endothelial cell counts were tabulated and statistical analysis performed. Using conventional detachable-type and modified aneurysm coils 11 of 14 (78.6%) harvested endothelial cells with a mean of 7.93 (±8.33) cells/coil, while 15 of 15 (100%) conventional stents, stent-like devices and modified stents harvested endothelial cells with a mean of 831.33 (±887.73) cells/device. Coil stiffness was significantly associated with endothelial cell count in univariate analysis (p = 0.044). For stents and stent-like devices univariate analysis demonstrated stent-to-aorta diameter ratios (p = 0.001), stent length (p = 0.049), and the use of a pulling retrieval technique (p = 0.019) significantly predictive of endothelial cell counts, though a multivariate model using these variables demonstrated only the stent-to-aorta diameter ratio (p = 0.029) predictive of endothelial cell counts. Modified devices did not significantly impact harvesting. The efficacy and safety of existing aneurysm coils, intracranial stents and stent-like devices in collecting viable endothelial cells was confirmed. The technique is reproducible and the quantity and quality of collected endothelial cells is adequate for targeted genetic analysis.
© The Author(s) 2015 Reprints and permissions:]br]sagepub.co.uk/journalsPermissions.nav.

Entities:  

Keywords:  Stroke; aneurysm; coil; endothelial cell; stent

Mesh:

Year:  2015        PMID: 25934786      PMCID: PMC4757193          DOI: 10.15274/inr-2014-10103

Source DB:  PubMed          Journal:  Interv Neuroradiol        ISSN: 1591-0199            Impact factor:   1.610


  22 in total

1.  Endothelial cell high-enrichment from endovascular biopsy sample by laser capture microdissection and fluorescence activated cell sorting.

Authors:  Zhengda Sun; Hua Su; Brian Long; Elizabeth Sinclair; Steven W Hetts; Randall T Higashida; Christopher F Dowd; Van V Halbach; Daniel L Cooke
Journal:  J Biotechnol       Date:  2014-12-20       Impact factor: 3.307

2.  International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised trial.

Authors:  Andrew Molyneux; Richard Kerr; Irene Stratton; Peter Sandercock; Mike Clarke; Julia Shrimpton; Rury Holman
Journal:  Lancet       Date:  2002-10-26       Impact factor: 79.321

3.  Histologic evaluation of platinum coil embolization in an aneurysm model in rabbits.

Authors:  D F Kallmes; G A Helm; S B Hudson; T A Altes; H M Do; J W Mandell; H J Cloft
Journal:  Radiology       Date:  1999-10       Impact factor: 11.105

4.  Endovascular biopsy: evaluating the feasibility of harvesting endothelial cells using detachable coils.

Authors:  Daniel L Cooke; Hua Su; Zhengda Sun; Yi Guo; Diana Guo; Maythem M Saeed; Steven W Hetts; Randall T Higashida; Christopher F Dowd; William L Young; Van V Halbach
Journal:  Interv Neuroradiol       Date:  2013-12-18       Impact factor: 1.610

5.  Human endothelium: endovascular biopsy and molecular analysis.

Authors:  L Feng; D M Stern; J Pile-Spellman
Journal:  Radiology       Date:  1999-09       Impact factor: 11.105

6.  Unruptured intracranial aneurysms in the Familial Intracranial Aneurysm and International Study of Unruptured Intracranial Aneurysms cohorts: differences in multiplicity and location.

Authors:  Jason Mackey; Robert D Brown; Charles J Moomaw; Laura Sauerbeck; Richard Hornung; Dheeraj Gandhi; Daniel Woo; Dawn Kleindorfer; Matthew L Flaherty; Irene Meissner; Craig Anderson; E Sander Connolly; Guy Rouleau; David F Kallmes; James Torner; John Huston; Joseph P Broderick
Journal:  J Neurosurg       Date:  2012-04-27       Impact factor: 5.115

7.  Molecular anatomy of an intracranial aneurysm: coordinated expression of genes involved in wound healing and tissue remodeling.

Authors:  D G Peters; A B Kassam; E Feingold; E Heidrich-O'Hare; H Yonas; R E Ferrell; A Brufsky
Journal:  Stroke       Date:  2001-04       Impact factor: 7.914

8.  Unruptured intracranial aneurysms: natural history, clinical outcome, and risks of surgical and endovascular treatment.

Authors:  David O Wiebers; J P Whisnant; J Huston; I Meissner; R D Brown; D G Piepgras; G S Forbes; K Thielen; D Nichols; W M O'Fallon; J Peacock; L Jaeger; N F Kassell; G L Kongable-Beckman; J C Torner
Journal:  Lancet       Date:  2003-07-12       Impact factor: 79.321

9.  Upregulation of cyclooxygenase-2 (COX-2) and microsomal prostaglandin E2 synthase-1 (mPGES-1) in wall of ruptured human cerebral aneurysms: preliminary results.

Authors:  David Hasan; Tomoki Hashimoto; David Kung; R Loch Macdonald; H Richard Winn; Donald Heistad
Journal:  Stroke       Date:  2012-05-15       Impact factor: 7.914

10.  Risk of recurrent subarachnoid haemorrhage, death, or dependence and standardised mortality ratios after clipping or coiling of an intracranial aneurysm in the International Subarachnoid Aneurysm Trial (ISAT): long-term follow-up.

Authors:  Andrew J Molyneux; Richard S C Kerr; Jacqueline Birks; Najib Ramzi; Julia Yarnold; Mary Sneade; Joan Rischmiller
Journal:  Lancet Neurol       Date:  2009-03-28       Impact factor: 44.182

View more
  2 in total

1.  Endovascular Biopsy: In Vivo Cerebral Aneurysm Endothelial Cell Sampling and Gene Expression Analysis.

Authors:  Daniel L Cooke; David B McCoy; Van V Halbach; Steven W Hetts; Matthew R Amans; Christopher F Dowd; Randall T Higashida; Devon Lawson; Jeffrey Nelson; Chih-Yang Wang; Helen Kim; Zena Werb; Charles McCulloch; Tomoki Hashimoto; Hua Su; Zhengda Sun
Journal:  Transl Stroke Res       Date:  2017-09-13       Impact factor: 6.829

2.  Endoluminal Biopsy for Molecular Profiling of Human Brain Vascular Malformations.

Authors:  Ethan Winkler; David Wu; Eugene Gil; David McCoy; Kazim Narsinh; Zhengda Sun; Kerstin Mueller; Jayden Ross; Helen Kim; Shantel Weinsheimer; Mitchel Berger; Tomasz Nowakowski; Daniel Lim; Adib Abla; Daniel Cooke
Journal:  Neurology       Date:  2022-02-10       Impact factor: 9.910

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.