Literature DB >> 25933057

Correction: bacterial viability and physical properties of antibacterially modified experimental dental resin composites.

.   

Abstract

Entities:  

Year:  2015        PMID: 25933057      PMCID: PMC4416748          DOI: 10.1371/journal.pone.0126198

Source DB:  PubMed          Journal:  PLoS One        ISSN: 1932-6203            Impact factor:   3.240


× No keyword cloud information.
There is a section missing from the Materials and Methods. The section should appear between the “Manufacturing of the delivery system” and the “Analytical data” subsections. The publisher apologizes for this error. The missing section is:

Synthesis of Methacryl-Irga [30–32]

23.5 g (81.2 m mol) Irgasan and 7.78 g (77 m mol) triethylamin (99%, Acros Organics, Geel, Belgium) were dissolved in 350 ml tetrahydrofuran (stabilized, Acros Organics), extra dried over molecular sieve, water content < 50 ppm in a 1-l three-necked flask with reflux condenser. The solution was cooled to 0°C and 7.71 g (73.8 m mol) methacryloyl chloride (> 97%, Sigma Aldrich GmbH, Taufkirchen, Germany) was dropped thereto within 90 min while stirring. After stirring overnight at room temperature, the reaction mixture was filtered to remove precipitated triethylamin hydrochloride. Phenothiazine (Sigma Aldrich) was added and tetrahydrofuran was distilled off. The crude product was dissolved in 100 ml n-hexane (Sigma Aldrich), washed with 5% sodium bicarbonate solution (3 x 40 ml), then with aqua dest. (4 x 50 ml). The organic phase was filtered over basic aluminium oxide and distilled. Yield: 22.36 g (63 m mol, 81.8%). 1H-NMR and 13C-NMR (Bruker Advance DRX 500 spectrometer, Bruker BioSpin GmbH, Rheinstetten, Germany) were performed; 500.13 MHz for proton and 125.77 MHz for carbon in CDCl3. The δ-scale relative to tetramethylsilan was calibrated to the solvent value δ = 7.24 ppm for CDCl3. IR spectra were recorded (Nicolet 5 SXB FT-IR Spectrometer, Thermo Scientific, Karlsruhe, Germany) with an attenuated total reflection (ATR) unit. Structure analysis was done with gas chromatography-mass spectrometry (GC/MS, Thermo Finnigan Trace DSQ, Dual-Stage Quadrupole, Thermo Scientific) and electron ionization (EI).
  1 in total

1.  Bacterial viability and physical properties of antibacterially modified experimental dental resin composites.

Authors:  Stefan Rüttermann; Taina Trellenkamp; Nora Bergmann; Thomas Beikler; Helmut Ritter; Ralf Janda
Journal:  PLoS One       Date:  2013-11-01       Impact factor: 3.240

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.